After 10 years, loosening of total joint endoprostheses occurs in about 3 to 10 percent of all patients, requiring elaborate revision surgery. A periprosthetic membrane is routinely found between bone and loosened prosthesis. Further histomorphological examination allows determination of the etiology of the loosening process. Aim of this study is the introduction of clearly defined histopathological criteria for a standardized evaluation of the periprosthetic membrane. Based on histomorphological criteria and polarized light microscopy, four types of the periprosthetic membrane were defined: periprosthetic membrane of wear particle type (type I), periprosthetic membrane of infectious type (type II), periprosthetic membrane of combined type (type III), periprosthetic membrane of indifferent type (type IV). Periprosthetic membranes of 268 patients were analyzed according to the defined criteria. The correlation between histopathological and microbiological diagnosis was high (89%, p<0,001), the inter-observer reproducibility was sufficient (95%). This classification system enables a standardized diagnostic procedure and therefore is a basis for further studies concerning the etiology of and pathogenesis of prosthesis loosening.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.