This narrative review aims to evaluate the current evidence for the application of magnetic resonance imaging (MRI), a radiation-free diagnostic exam, in some fields of dentistry. Background: Radiographic imaging plays a significant role in current first and second level dental diagnostics and treatment planning. However, the main disadvantage is the high exposure to ionizing radiation for patients. Methods: A search for articles on dental MRI was performed using the PubMed electronic database, and 37 studies were included. Only some articles about endodontics, conservative dentistry, implantology, and oral and craniofacial surgery that best represented the aim of this study were selected. Results: All the included articles showed that MRI can obtain well-defined images, which can be applied in operative dentistry. Conclusions: This review highlights the potential of MRI for diagnosis in dental clinical practice, without the risk of biological damage from continuous ionizing radiation exposure.
Background: Cephalometry is fundamental in diagnosis, analysis, and planning of orthodontic-surgical treatment as it reveals skeletal relationship between the upper and lower jaw as well as facial aesthetic parameters. Nevertheless, 3D cephalometry has still not become the exam of choice in orthognathic treatment even though today CBCT (Cone Beam Computed Tomography) is routinely used in other branches of dentistry. Methods: In a sample of 13 patients undergoing bimaxillary orthognathic surgery a chin-vertex CBCT exam was prescribed prior to orthodontic treatment (OT) and 12 months after surgery (T1). The DICOM files uploaded to MaterialiseSimplant Ortho software pro 2.1 (Materialise Co., Leuven, Belgium) were analyzed following the multiplane 3D Total Face cephalometry protocol (TFA). Results: Results comparing pre-op and post-op TFA 3D cephalometry, were then evaluated considering reference values reported in literature. The CBCT, carried out pre- and post-surgery, were subsequently analyzed employing the superimposition method using cranial base as reference. The aim of this study is to evaluate the advantages and disadvantages of the two methods in orthognathic surgery. Conclusions: Multiplane 3D TFA allows the clinician to locate where major or minor skeletal discrepancies are found with respect to ideal parameters and is also useful in classifying skeletal intermaxillary relation. The superimposition method is highly intuitive but does not provide information on the quantity and location of osteotomic movement.
Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.
To prevent re-infection and provide a hermetic seal of the root canal system, an endodontist must aim to produce a void-free obturation. This review aimed to compare the completeness of root canal obturation between the two most prevalent methods—cold lateral condensation and warm gutta-percha techniques—using micro-CT (PROSPERO reg no. 249815). Materials and Methods: A search of Scopus, Embase, PubMed (Medline via PubMed), and Web of Science databases was done without any time restriction according to the PRISMA protocol. Articles that compared both techniques and were published in English were included. Data was extracted and the risk of bias was assessed using an adapted tool based on previous studies. Results: A total of 141 studies were identified by the search. Following the screening and selection of articles, 9 studies were included for review. Data was extracted manually and tabulated. Most studies had a moderate risk of bias. None determined operator skill in both methods before comparison. The data extracted from the included studies suggests that both techniques produce voids in the obturation. The thermoplasticized gutta-percha techniques may result in fewer voids compared to cold lateral condensation. Conclusion: Considering the limitations of the included studies, it was concluded that neither technique could completely obturate the root canal. Thermoplasticized gutta-percha techniques showed better outcomes despite a possible learning bias in favor of cold lateral condensation. Establishing operator skills before comparison may help reduce this bias.
(1) Background: the frequency with which diagnostic tests are prescribed with exposure to ionizing radiation, a cause of biological damage, has been studied, and with much more attention, patients are subjected to these diagnostic tests for diagnosis and follow-up. This review aimed, given the recent developments of this technology, to evaluate the possible use of ultrasound in different branches of dentistry. The possibility of applying ionizing-radiation-free diagnostic exams in dentistry, overcoming the limits of this application, has led scientific research in this area to obtain interesting results that bode well for the future. (2) Methods: a search for articles on the application of ultrasounds in dentistry was performed using the PubMed electronic database. (3) Results: only 32 studies were included, and these clearly stated that this examination is widely usable and in great progress. (4) Conclusions: regarding the modern application techniques of this diagnostic test, it is essential to consider technological evolution as an objective to reduce the damage and side effects of necessary diagnostic tests. The use of ultrasound in dentistry can represent a valid radiation-free alternative, in certain contexts, to the other most used exams.
The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.
Objectives: To compare gingival tissue healing at surgically manipulated periodontal sites and at sites receiving implants and healing abutments with machined (MS) vs laser-microtextured (LMS) surface placed with one-stage protocol.Material and Methods: Twenty-four non-smoking patients each received two implants with one-stage protocol in a split-mouth design on the same jaw. In each patient, one implant with a MS collar and one immediate healing abutment with a MS, and one implant with a LMS collar and one immediate healing abutment with a LMS were used. Soft tissues healing at surgically manipulated periodontal tissues (T+) and at non-surgically manipulated periodontal tissues (T-) at MS implant sites and at LMS implant sites were compared by means of clinical and biochemical parameters at baseline and at 1-2-3-4-6-8 and 12 weeks.Results: PD and BoP mean values were statistically higher in MS than LMS implant sites (p<0.05). During early healing phase (1-4 weeks), MS and LMS peri-implant tissues and periodontal tissues at T(+) showed no statistically significant difference in crevicular fluid volume changes (p>0.05). Between 6 and 12 weeks, compared with T(+), no statistically significant difference in crevicular fluid volume and IL-6 and IL-1β concentrations was noted in LMS implant sites (p>0.05), while statistically significantly higher mean values were noted in MS implant sites (p<0.05).Conclusions: Compared with T(+) and T(-), both MS and LMS implant sites presented a higher pro-inflammatory state in the early phase after surgery (1-4 weeks). At 12 weeks, only MS implant sites kept a higher pro-inflammatory state, while at LMS implant sites, it becomes similar to T(+) and T(-).
Background: Ultrasonography is a non-invasive method of diagnosing periapical lesions while radiologic methods are more common. Periapical lesions due to endodontic infection are one of the most common causes of periapical radiolucency that need to be distinguished to help determine the course of treatment. This review aimed to examine the accuracy of ultrasound and compare it to radiographs in distinguishing these lesions in vivo. Methods: This review process followed the PRISMA guidelines. A literature search of databases (PubMed, Scopus, Embase, and Web of Science) was conducted without any restrictions on time. Articles available in English were included. The selection was done according to the inclusion and exclusion criteria. The QUADAS-2 tool was used to assess the quality of the studies. Results: The search provided a total of 87 articles, out of which, five were selected for the final review. In all the studies, ultrasound had higher accuracy in distinguishing periapical lesions. All the studies indicated a risk of bias, especially in patient selection. Conclusion: Within limitations, the study indicates that ultrasound is a better diagnostic tool to distinguish periapical lesions compared to radiographs but further studies with well-designed, rigorous protocols and low risk of bias are needed to provide stronger evidence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.