Study Design: An experimental in vitro study. Objective: Plate fractures are a recurrent problem in alloplastic mandibular reconstruction. Hypothetically it can be assumed that computer-aided design (CAD)/computer-aided manufacturing (CAM) reconstruction plates have a higher stability than conventional hand-bent plates. The aim of the study was to compare additive and subtractive fabricated CAD/CAM mandibular reconstruction plates as well as conventional plates with regard to their biomechanical properties. Methods: In a chewing simulator, plates of 2 conventional locking plate systems and 2 CAD/CAM-fabricated plate systems were compared. The plates were loaded in a fatigue test. The maximum number of cycles until plate fracture and the plate stiffness were compared. Results: While all conventional plates fractured at a maximum load between 150 and 210 N (Newton) after a number of cycles between 40 000 and 643 000, none of the CAD/CAM plates broke despite a nearly doubled load of 330 N and 2 million cycles. Both CAD/CAM systems proved to be significantly superior to the hand-bent plates. There was no difference between the 2 CAD/CAM systems. Conclusions: Concerning the risk of plate fracture, patient-specific CAD/CAM reconstruction plates appear to have a significant advantage over conventional hand-bent plates in alloplastic mandibular reconstruction.
Medication-related osteonecrosis of the jaw (MRONJ) has been an integral part of the maxillofacial patient population for some time. The therapeutic concept ranges from conservative approaches over less extended decortications to major jaw resections, which can result in a considerable loss of quality of life. Based on three case reports, this paper presents the long-term history of patients with MRONJ of the mandible, whose disease ultimately resulted in partial or total mandibular resection and subsequent multisegmental reconstruction using a microvascular anastomosed bone flap. Furthermore, a suitable alternative for complex mandibular reconstruction is demonstrated when using a free fibula flap is not possible. The options are limited, particularly when multisegmental restoration of mandibular continuity is required. One case presents a mandible reconstruction using a CAD/CAM-guided bilateral scapular free flap (CAD/CAM = Computer-Aided Design and Manufacturing), which has not been described for this purpose before. Due to the complexity, computer-assisted surgery and patient-specific implants seem reasonable, which is why a special focus was applied to this topic.
Background/Aim: Reconstruction of the fractured orbit remains a challenge. The aim of this study was to compare anatomical preformed titanium orbital implants with patient-specific CAD/CAM implants for precision and intraoperative applicability. Material and Methods: A total of 75 orbital reconstructions from 2012 to 2022 were retrospectively assessed for their precision of implant position and intra- and postoperative revision rates. For this purpose, the implant position after digital orbital reconstruction was checked for deviations by mirroring the healthy orbit at 5 defined points, and the medical records of the patients were checked for revisions. Results: The evaluation of the 45 anatomical preformed orbital implant cases showed significantly higher deviations and an implant inaccuracy of 66.6% than the 30 CAD/CAM cases with only 10% inaccuracy. In particular, the CAD/CAM implants were significantly more precise in medial and posterior positioning. In addition, the intraoperative revision rates of 26.6% vs. 11% after 3D intraoperative imaging and the postoperative revision rates of 13% vs. 0 for the anatomical preformed implants were significantly higher than for patient-specific implants. Conclusion: We conclude that patient-specific CAD/CAM orbital implants are highly suitable for primary orbital reconstruction. These seem to be preferable to anatomical preformed implants in terms of precision and revision rates.
Background/Aim: The primary aim was to evaluate the prevalence and localisation of dental injuries caused by osteosynthesis screws during orthognathic surgery, comparing two different CAD/CAM planning/surgical approaches through retrospective evaluation of post-operative computed tomography. Material and Methods: This study considered all patients who underwent orthognathic surgery from 2010–2019. The examination for dental root injuries between conventional osteosynthesis (Maxilla conventional cohort) and osteosynthesis with patient-specific implant (Maxilla PSI cohort) was performed by evaluating the post-operative CT scans. Results: A total of 126 patients were included in the study. Among the 61 patients of the Maxilla conventional cohort, 10 dental root injuries in 8 patients (13.1%) were detected in the post-operative CT scan, representing 1.5% (n = 10/651) of the osteosynthesis screws inserted in proximity of the alveolar crest. No dental injury occurred following osteosynthesis in the 65 patients of the Maxillary PSI cohort (n = 0/773 screws) (p < 0.001). During a mean follow-up period of 13 months after primary surgery, none of the injured teeth showed evidence of periapical alterations and no endodontic treatments were necessary. Conclusions: Maxillary positioning using CAD/CAM-fabricated drill/osteotomy guide and osteosynthesis with PSI can significantly reduce the risk for dental injury compared to the conventional procedure. However, the clinical significance of the detected dental injuries was rather minor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.