Grip force was measured along two orthogonal axes and vector summed. Sixty-one participants recruited from a manufacturing facility (29 men and 32 women) grasped instrumented cylinders (2.54, 3.81, 5.08, 6.35, and 7.62 cm diameter) using a maximal voluntary power grip. Two orthogonal force measurements relative to the third metacarpal were resolved into a magnitude and corresponding angle. On average, magnitude increased 34.8 N as handle diameter increased from 2.54 cm to 3.81 cm, and then monotonically declined 103.8 N as the handle diameter increased to 7.62 cm. The average direction monotonically decreased from 59.2 degrees to 37.7 degrees as handle diameter decreased from the largest to the smallest. When the diameter was smallest, the greatest force component, Fx (168.6 N), was in the direction where the fingertips opposed the palm. Conversely, when the diameter was largest, the smallest component, Fx (77.7 N), was in the same direction. These values are averaged for the left and right hand. The angle for the largest diameter increased with increasing hand size. These relationships should be useful for the design of handles that require gripping in specific directions, such as for hand tools and controls. Actual or potential applications of this research include the design of handles that require gripping in specific directions, such as for hand tools and controls, that reduce effort, and that prevent fatigue and overexertion.
The discrete movement task employed in this study consisted of moving a cursor from the center of a computer display screen to circular targets located 24.4 and 110.9 mm in eight radial directions. The target diameters were 2.7, 8.1, and 24.2 mm. Performance measures included movement time, cursor path distance, and root-mean-square cursor deviation. Ten subjects with no movement disabilities were studied using a conventional mouse and a lightweight ultrasonic head-controlled computer input pointing device. Average movement time was 306 ms greater (63%) for the head-controlled pointer than for the mouse. The effect of direction on movement time for the mouse was relatively small compared with the head-controlled pointer, which was lowest at 90 and 270 deg, corresponding to head extension and head flexion, respectively. Average path distance and root mean square displacement was lowest at off-diagonal directions (0, 90, 180, and 270 deg). This methodology was also shown to be useful for evaluating performance using an alternative head-controlled input device for two subjects having cerebral palsy, and measured subtle performance improvements after providing a disabled subject with lateral torso support.
The goal of this study was to compare the relative performance of two noninvasive ventilation sensing technologies on adults during artifacts. We recorded changes in transthoracic impedance and cross-sectional area of the abdomen (abd) and rib cage (rc) using impedance pneumography (IP) and respiratory inductance plethysmography (RIP) on ten adult subjects during natural breathing, motion artifact, simulated airway obstruction, yawning, snoring, apnea, and coughing. We used a pneumotachometer to measure air flow and tidal volume as the standard. We calibrated all sensors during natural breathing, and performed measurements during all maneuvers without changing the calibration parameters. No sensor provided the most-accurate measure of tidal volume for all maneuvers. Overall, the combination of inductance sensors [RIP(sum)] calibrated during an isovolume maneuver had a bias (weighted mean difference) as low or lower than all individual sensors and all combinations of sensors. The IP(rc) sensor had a bias as low or lower than any individual sensor. The cross-correlation coefficient between sensors was high during natural breathing, but decreased during artifacts. The cross correlation between sensor pairs was lower during artifacts without breathing than it was during maneuvers with breathing for four different sensor combinations. We tested a simple breath-detection algorithm on all sensors and found that RIP(sum) resulted in the fewest number of false breath detections, with sensitivity of 90.8% and positive predictivity of 93.6%.
A brain-computer interface (BCI) is a communication system that takes recorded brain signals and translates them into real-time actions, in this case movement of a cursor on a computer screen. This work applied Fitts’ law to the evaluation of performance on a target acquisition task during sensorimotor rhythm-based BCI training. Fitts’ law, which has been used as a predictor of movement time in studies of human movement, was used here to determine the information transfer rate, which was based on target acquisition time and target difficulty. The information transfer rate was used to make comparisons between control modalities and subject groups on the same task. Data were analyzed from eight able-bodied and five motor disabled participants who wore an electrode cap that recorded and translated their electroencephalogram (EEG) signals into computer cursor movements. Direct comparisons were made between able-bodied and disabled subjects and between EEG and joystick cursor control in able-bodied subjects. Fitts’ law aptly described the relationship between movement time and index of difficulty for each task movement direction when evaluated separately and averaged together. This study showed that Fitts’ law can be successfully applied to computer cursor movement controlled by neural signals.
Repetitive trauma disorders of the upper extremity are a major cause of lost work in many hand-intensive industries. Reported risk factors include repetitive and forceful exertions, certain postures, mechanical stress, low temperatures, gloves, and vibration. Risk factors can be identified with job analysis procedures based on traditional work-methods analysis. Risk factors can be controlled through reallocation of work, balancing of tools, selection of alternative tool designs, work relocation, selection of suitable hand protection, and elimination of hand exposure to low temperatures and vibration. Drawing-board manikins are used with computer-aided design systems to estimate the best work location for a given task.
Surface electromyography was used for studying the effects of torque reaction force acting against the hand, on forearm muscle activity and grip force for five subjects operating right angle, air shut-off nutrunners. Four tools having increasing spindle torque were operated using short and long torque reaction times. Nutrunner spindle torque ranged between 30 Nm and 100 Nm. Short torque reaction time was considered 0.5 s while long torque reaction time was 2 s. Peak horizontal force was the greatest component of the reaction force acting against the hand and accounted for more than 97% of the peak resultant hand force. Peak hand force increased from 89 N for the smallest tool to 202 N for the largest tool. Forearm muscle rms EMG, scaled for grip force, indicated average flexor activity during the Torque-reaction phase was more than four times greater than the Pre-start and Post Shut-off phases, and two times greater than the Run-down phase. Flexor EMG activity during the Torque-reaction phase increased for increasing tool peak spindle torque. Average flexor rms EMG activity, scaled for grip force, during the Torque-reaction phase increased from 372 N for the 30 Nm nutrunner to 449 N for the 100 Nm nutrunner. Flexor rms EMG activity averaged during the Torque-reaction phase and scaled for grip force was 390 N for long torque reaction times and increased to 440 N for short torque reaction times. Flexor rms EMG integrated over the torque reaction phase was 839 Ns for long torque reaction times and decreased to 312 Ns for short torque reaction times. The average latency between tool spindle torque onset and peak initial flexor rms EMG for long torque reaction times was 294 ms which decreased to 161 ms for short torque reaction times. The average latency between peak tool spindle torque, just prior to tool shut-off, and peak final rms EMG for long torque reaction times was 97 ms for flexors and 188 ms for extensors, which decreased for short torque reaction times to 47 ms for flexors and 116 ms for extensors. The results suggest that right angle nutrunner torque reaction forces can affect extrinsic hand muscles in the forearm, and hence grip exertions, by way of a reflex response.(ABSTRACT TRUNCATED AT 400 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.