Ventricular tachycardias occur more often in PH patients than previously reported. However, the prognostic relevance of non-sustained ventricular tachycardias in this cohort remains unclear. As a large number of PH patients die from SCD, closer monitoring, e.g., using implantable event recorders, might be useful to identify patients at high risk.
The Bogossian formula is a reliable tool for QTc interval evaluation in pacemaker patients with LBBB due to apical or non-apical RV pacing. However, an overestimation of 30 ms should be included in the calculation.
The novel Bogossian formula seems to be a reliable tool for QTc interval evaluation in patients with heart failure and right ventricular pacing. However, a slight overestimation of the QT-interval must be respected.
Purpose. In this study, our purpose was to investigate the diagnostic efficacy of the dynamic contrast-enhanced magnetic resonance imaging (MRI) method in the patients with bile duct obstruction.
Materials and Methods. 108 consecutive patients (53 men, 55 women, mean age; 55.77 ± 14.62, range 18–86 years) were included in this study. All the patients underwent conventional upper abdomen MRI using intravenous contrast material (Gd-DTPA) and MRCP in 1.5 Tesla MRI scanner. MRCP images were evaluated together with the T1 and T2w images, and both biliary ducts and surrounding tissues were examined for possible pathologies that may cause obstruction. Results. MRI/MRCP findings compared with final diagnoses, MRI/MRCP in the demonstration of bile duct obstruction sensitivity 96%, the specificity 100%, and accuracy 96.3%, in the detection of presence and level of obstruction, the sensitivity 96.7%, specificity 100%, and accuracy 97.2%, in the diagnosis of choledocholithiasis, the sensitivity 82.3%, specificity 96%, and accuracy 91.7%, and in the determination of the character of the stenosis, sensitivity 95.6%, specificity 91.3%, and accuracy 94.5% were found. Conclusion. The combination of dynamic contrast-enhanced MRI and MRCP techniques in patients with suspected biliary obstruction gives the detailed information about the presence of obstruction, location, and causes and is a highly specific and sensitive method.
Effective cardiac resynchronization therapy (CRT) requires an accurate atrio-biventricular pacing system. The innovative Quartet lead is a quadripolar, over-the-wire left ventricular lead with four electrodes and has recently been designed to provide more options and greater control in pacing vector selection. A lead with multiple pacing electrodes is a potential alternative to physical adjustment of the lead and may help to overcome high thresholds and phrenic nerve stimulation (PNS).
Unipolar DDD pacing bears a high risk of false triggering of the WCD detection algorithm. Other types of unipolar pacing and all bipolar pacing modes do not seem to mislead the WCD detection algorithm. Therefore, patients with no reprogrammable unipolar DDD pacing should not become candidates for the WCD.
Background
Since the outbreak of the coronavirus disease 2019 (COVID-19) pandemic, various strategies have been taken worldwide to reduce the risk of infection. As part of the amendment to the Infection Protection Act, elective medical interventions were restricted, leading to a change in patient care. However, the consequences of the lockdown on the treatment of rhythmological patients in Germany remains unclear.
Objectives
The aim of this study was to analyze the reduction in rhythmological interventions and the patient care situation using a nationwide survey during the first lockdown period.
Methods
A survey was sent to all electrophysiological centers certified by the German Society of Cardiology. Here, the treatment volume of tachycardia and bradycardia and their invasive therapy were surveyed before and during the lockdown period. Furthermore, the number of patients with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) treated at these centers and the incidence of cardiac arrhythmias was also recorded.
Results
Participating centers performed a total of 24,648 ablation procedures/year and represent approximately 34% (24,648/72,548) of the estimated German ablation treatments. The majority of these centers (33/40; 82.5%) were so-called primary COVID-19 hospitals (level-1). Overall, the number of ablations and pacemaker implantations were reduced by 41% and 18% respectively. Due to postponed ablation procedures and pacemaker implantations, 22/40 (55%) centers reported a worsening of clinical symptoms or early re-hospitalization of their patients.
Conclusion
These results demonstrate a significant decline in elective rhythmological procedures during the lockdown, as required by the German Federal Government. At the same time, however, more than half of the participating centers reported an increase in patient re-hospitalizations due to postponed procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.