Severe neonatal hyperbilirubinemia, defined as total serum bilirubin (TSB) ≥20 mg/dl, is associated with a higher risk of permanent neurological sequelae and death. Jaundice can and should be promptly diagnosed and treated. Reliable methods for TSB assay are not always readily available, particularly in low- and middle-income countries, making the true incidence of severe neonatal jaundice (NNJ) difficult to estimate. To gather a more comprehensive picture, a symposium addressing NNJ worldwide was organized during the 2015 Don Ostrow Trieste Yellow Retreat. Data collected by several researchers in different regions of the world were presented and differences/similarities discussed. This report points out the need for: (1) a coordinated worldwide effort to define the burden and the causes of severe NNJ and its consequences; (2) aggressive educational programs for families and health personnel to facilitate timely care-seeking, and (3) accurate diagnostics and effective phototherapy.
PurposeFeeding tolerance is extremely important in preterm infants. This study aimed to evaluate whether preterm infants receiving Lactobacillus reuteri DSM 17938 would develop fewer symptoms of feeding intolerance. Secondary outcomes were duration of parenteral nutrition, time to reach full feeding, length of hospital stay, sepsis, necrotizing enterocolitis (NEC), diarrhea, and mortality.MethodsThis double-blind randomized controlled trial of L. reuteri DSM 17938 versus placebo included 94 neonates with a gestational age of 28–34 weeks and birth weight of 1,000–1,800 g.ResultsFeeding intolerance (vomiting and/or distension) was less common in the probiotic group than in the placebo group (8.5% vs. 25.5%; relative risk, 0.33; 95% confidence interval, 0.12–0.96; p=0.03). No significant intergroup differences were found in proven sepsis, time to reach full feeding, length of hospital stay, or diarrhea. The prevalence of NEC (stages 2 and 3) was 6.4% in the placebo group vs. 0% in the probiotic group (relative risk, 1.07; 95% confidence interval, 0.99–1.15; p=0.24). Mortality rates were 2.1% in the probiotic group and 8.5% in the placebo group, p=0.36).ConclusionThe administration of L. reuteri DSM 17938 to preterm infants was safe and significantly reduced feeding intolerance. No significant differences were found in any other secondary outcomes.
Importance The real prevalence and clinical burden of severe neonatal jaundice are undefined due to difficulties in measuring total serum bilirubin (TSB) outside secondary and tertiary clinical centers. Objective To assess the diagnostic performance of the point-of care Bilistick System (BS) in identifying neonatal jaundice patients requiring treatment. Design Between April 2015 and November 2016, 1911 neonates, were recruited to participate in the study. Blood samples were simultaneously collected for the TSB determination by BS and by hospital laboratory (Lab). Data were collected and sent to the Bilimetrix headquarter in Trieste where statistical analysis was performed. Newborns with neonatal jaundice were treated with phototherapy according to each center's guidelines. Setting 17 hospitals from Nigeria, Egypt, Indonesia, and Viet Nam. Participants 1911 newborns were included, of which 1458 (76·3%) fulfilled the inclusion criteria. Results TSB level measured by BS agreed (p < .0001) with the lab result in all four countries. The diagnostic performance of BS showed a positive predictive value (PPV) of 92·5% and a negative predictive value (NPV) of 92·8%. Conclusions and Relevance BS is a reliable system to detect neonatal jaundice over a wide range of bilirubin levels. Since Bilistick is a point-of-care test, its use may provide appropriate and timely identification of jaundiced newborns requiring treatment.
BackgroundThis study compares the minimally invasive Bilistick and a noninvasive method with standard Total Serum Bilirubin (TSB) measurement in preterm newborns receiving phototherapy. We assess the agreement of Transcutaneous Bilirubinometer (TcB) and Bilistick bilirubin measurements with standard TSB measurement in preterm infants receiving phototherapy.MethodsBilirubin was measured by using TcB and Bilistick in 94 preterm infants in RSCM Jakarta Neonatal Ward from October 2016 to March 2017, with gestational ages of < 35 weeks, before phototherapy and after 24 and 48 h of phototherapy.ResultsThere was significant correlation before, at 24 and 48 h of phototherapy between TSB and either TcB (r = 0.874; r = 0.889; r = 0.878 respectively; p < 0.0001), or Bilistick (r = 0.868; r = 0.877; r = 0.918 respectively; p < 0.0001). The mean difference and limits of agreement before, at 24 and 48 h of phototherapy between TcB and TSB were 0.81 ± 1.51 mg/dL (− 2.14 to 3.77 mg/dL); 0.43 ± 1.57 mg/dL (− 2.66 to 3.51 mg/dL); 0.41 ± 1.58 mg/dL (− 2.69 to 3.50 mg/dL), respectively. For Bilistick they were − 1.50 ± 1.47 mg/dL (− 4.38 to 1.38 mg/dL); − 1.43 ± 1.47 mg/dL (− 4.32 to 1.46 mg/dL); − 1,15 ± 1.31 mg/dL (− 3,72 to 1,42 mg/dL), respectively.ConclusionsBoth methods are reliable for measuring TSB before, during, and after phototherapy in preterm infants. TcB tends to overestimate while Bilistick underestimates TSB.
Background The successful promotion of facility births in low and middle-income countries has not always resulted in improved neonatal outcome. We evaluated key signal functions pertinent to Level II neonatal care to determine facility readiness to care for high risk/ small and sick newborns. Method Facility readiness for care of high risk/ small and sick babies was determined through self-evaluation using a pre-designed checklist to determine key signal functions pertinent to Level II neonatal care in selected referral hospitals in Uganda (10), Indonesia (4) and India (2) with focus on the Sub-Saharan country with greater challenges. Results Most facilities reported having continuous water supply, resources for hand hygiene and waste disposal. Delivery rooms had newborn corners for basic neonatal resuscitation, but few practiced proper reprocessing of resuscitation equipment. Birth weight records were not consistently maintained in the Ugandan hospitals. In facilities with records of birth weights, more than half (51.7%) of newborns admitted to the neonatal units weighed 2500 g or more. Neonatal mortality rates ranged from 1.5 to 22.5%. Evaluation of stillbirths and numbers of babies discharged against medical advice gave a more comprehensive idea of outcome. Kangaroo Mother Care was practiced to varying extents. Incubators were more common in Africa while radiant warmers were preferred in Indian hospitals. Tube feeding was practiced in all and cup feeding in most, with use of human milk at all sites. There were proportionately more certified pediatricians and nurses in Indonesia and India. There was considerable shortage of nursing staff, (worst nurse –bed ratio ranging from 1 to 15 in the day shift, and 1 to 30 at night). There was significant variability in facility readiness, as in data maintenance, availability of commodities such as linen, air -oxygen blenders and infusion pumps and of infection prevention practices. Conclusions Referral neonatal units in LMIC have challenges in meeting even the basic level II requirements, with significant variability in equipment, staffing and selected care practices. Facility readiness has to improve in concert with increased facility births of high risk newborns in order to have an impact on neonatal outcome, and on achieving Sustainable Development Goals 3.2.2. Electronic supplementary material The online version of this article (10.1186/s40748-019-0105-9) contains supplementary material, which is available to authorized users.
A ir susu ibu (ASI) merupakan nutrisi ideal untuk bayi karena mengandung zat gizi yang paling sesuai dengan kebutuhan bayi dan mengandung seperangkat zat perlindungan terhadap berbagai Kata kunci: ASI eksklusif, inisiasi menyusu dini, faktor yang memengaruhi
Serum GGT and AST values can be used to predict the prognosis of patients with sepsis-associated cholestasis.
ObjectiveThe genetic involvement in unconjugated neonatal hyperbilirubinemia has been extensively studied. Despite the high incidence of hyperbilirubinemia in Indonesia, studies are lacking. The objective of this study is to elucidate the role of polymorphism in the UGT1A1 in Neonatal Hyperbilirubinemia in Bengkulu, Indonesia.ResultsThere were 41 neonates enrolled in the study; 30 had a total serum bilirubin level ≥ 15 mg/dL (hyperbilirubinemia neonates) while 11 has < 15 mg/dL (control neonates). Genetic mutations in Exon 1, UGT1A1*6 (c211g > a) and one in promoter region, UGT1A1*60 (c3279t > g) were determined by polymerase chain reaction–restriction fragment length polymorphism. We found 18 (60%) mutation in exon 1 in hyperbilirubinemia group and 7 (64%) in the control group with an identical allele frequency of 0.3 in both groups. We found heterozygous UGT1A1*60 4 times (13.3%) and homozygous 26 times (86.7%) in the hyperbilirubinemia group, with an identical allele frequency of 0.935 in hyperbilirubinemia and 1 in control group. This study supports the involvement of genetic factors in the development of unconjugated hyperbilirubinemia in Bengkulu population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.