The simulations on hip joint implants aim to analyze the total deformation, maximum principal stress, and maximum shear stress with variations in time and motion activity (walking, jumping, and descending stairs). The method used in this simulation consists of design using Autodesk Inventor 2014 software, input material and properties, determining fix support, meshing, walking, and results using ANSYS 18.1 software. Finite element method analysis is based on walking, jumping, and descending stairs for 0 seconds to 0.45 seconds. The analysis showed that the hip joint implant produced 8333 nodes, 4534 elements, and total deformation of 0.39 mm (walking), 0.80 mm (jumping), and 0.90 mm (descending stairs). The maximum principal stresses are 192 MPa (walking), 397 MPa (jumping), and 438 MPa (descending stairs). The maximum shear stresses are 125 MPa (walking), 264 MPa (jump), and 291 MPa (descending stairs).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.