US of the common extensor tendon had high sensitivity but low specificity in the detection of symptomatic lateral epicondylitis. The relationship between symptoms and intratendinous calcification, tendon thickening, adjacent bone irregularity, focal hypoechoic regions, and diffuse heterogeneity was statistically significant.
In 28 fetuses studied during a 4 1/2-year period, the initial femur was below 2 standard deviations (SDs) of the mean when compared with the biparietal diameter. These fetuses were considered at risk for skeletal dysplasias and were followed up. Studies were performed at a mean gestational age of 26.7 weeks (range, 15.3-41.0 weeks). Group 1 had a femur length 1-4 mm below the 2-SDs line (range, -2.0 to -4.0 SDs); no other abnormalities were detected. Interval examination of 12 femurs showed that 10 either remained shortened to the same degree or had a growth spurt. At birth, all subjects were healthy except one with mild growth retardation and one with a chromosomal abnormality. Of the two subjects that failed to continue normal growth, one was healthy and the other was a heterozygous achondroplastic dwarf. Group 2 had greater femoral shortness; all measurements were more than 5 mm below the 2-SD line (range, -4.3 to -31.0 SDs). All had fetal abnormalities and significant skeletal dysplasias. The authors conclude that the number of millimeters below the 2-SDs line is an accurate, easy criterion for evaluation of femoral length.
High-frequency catheter-based ultrasound (US) transducers can be inserted into the esophagus transnasally to evaluate esophageal wall structures. Studies were performed in two sheep esophagus specimens in vitro, in 17 healthy human subjects, and in 16 patients with esophageal abnormalities (eight with achalasia, four with scleroderma, three with esophageal carcinoma, and one with esophagitis). In the sheep specimens, endoluminal US delineated seven layers of the esophageal wall; these results correlated closely with histologic findings. Real-time US of the normal esophageal wall was performed during resting and swallowing. Muscles at the lower esophageal sphincter (LES) were shown to be thicker than muscles in the body of the esophagus. Thickening of the muscular layers at the LES in achalasia, dilated blood vessels within the submucosa in esophagitis, and fibrotic changes within the muscular layers in scleroderma were demonstrated. Extramural structures adjacent to the esophagus were also seen. These preliminary results suggest that transnasal esophageal US may become an important diagnostic tool in evaluation of the esophagus.
For specific clinical indications, sonographically guided fine-needle aspiration and core biopsy of a solid renal mass can be performed safely. In many cases, a definitive diagnosis can be made on the basis of fine-needle aspiration alone. However, diagnosis may ultimately require core biopsy, for which 18-gauge core needles would be more reliably diagnostic than 20-gauge needles.
Background: Intraoperative ultrasound has been shown to provide significant assistance in operative staging and management of patients with liver tumors during open surgery. The availability of the 5.0-7.5 Mhz semiflexible ultrasound transducer with gray-scale, color and spectral Doppler capabilities can provide similar information laparoscopically. Methods: Twenty-four consecutive patients with liver tumors (18 metastatic and six primary), in technically resectable locations determined by a variety of conventional imaging studies, were brought to the operating room. There was no known extrahepatic disease, and there was no recurrence at the primary site in the metastatic subgroup. These patients were evaluated intraoperatively with laparoscopy and intraoperative laparoscopic ultrasound to assess resectability prior to performing a major laparotomy. Laparoscopy was successful in 23 of the patients and in 19 of 23, laparoscopic ultrasound was also employed, using the 5.0-7.5 MHz semiflexible transducer. The use of the open entry technique, selection of alternate entry sites, coupled with expertise in laparoscopic lysis of adhesions, has allowed safe laparoscopic tumor staging. Results: The laparoscopic evaluation was aborted only once due to dense adhesions, despite the fact that 67% of the patients had undergone previous abdominal surgery. There was only one complication: bleeding from a liver biopsy in an unresectable cirrhotic patient, necessitating laparotomy. Laparoscopy and ultrasound together predicted nonresectability in six of eight unresectable patients, all of whom were spared an unnecessary laparotomy. Conclusions: Laparoscopic ultrasonographic evaluation for the staging of liver tumors should be a prerequisite to definitive laparotomy, with the objective of avoiding unncessary surgery. J.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.