The worsening with age of technical systems performance is a matter of fact which is particularly timely to analyze for horizontal-axis wind turbines because they constitute a mature technology. On these grounds, the present study deals with the assessment of wind turbine performance decline with age. The selected test case is a Vestas V52 wind turbine, installed in 2005 at the Dundalk Institute of Technology campus in Ireland. Operation data from 2008 to 2019 have been used for this study. The general idea is analyzing the appropriate operation curves for each working region of the wind turbine: in Region 2 (wind speed between 5 and 9 m/s), the generator speed–power curve is studied, because the wind turbine operates at fixed pitch. In Region 2 12bevelledtrue (wind speed between 9 and 13 m/s), the generator speed is rated and the pitch control is relevant: therefore, the pitch angle–power curve is analyzed. Using a support vector regression for the operation curves of interest, it is observed that in Region 2, a progressive degradation occurs as regards the power extracted for given generator speed, and after ten years (from 2008 to 2018), the average production has diminished of the order of 8%. In Region 2 12bevelledtrue, the performance decline with age is less regular and, after ten years of operation, the performance has diminished averagely of the 1.3%. The gearbox of the test case wind turbine was substituted with a brand new one at the end of 2018, and it results that the performance in Region 2 12bevelledtrue has considerably improved after the gearbox replacement (+3% in 2019 with respect to 2018, +1.7% with respect to 2008), while in Region 2, an improvement is observed (+1.9% in 2019 with respect to 2018) which does not compensate the ten-year period decline (−6.5% in 2019 with respect to 2008). Therefore, the lesson is that for the test case wind turbine, the generator aging impacts remarkably on the power production in Region 2, while in Region 2 12bevelledtrue, the impact of the gearbox aging dominates over the generator aging; for this reason, wind turbine refurbishment or component replacement should be carefully considered on the grounds of the wind intensity distribution onsite.
Ageing of technical systems and machines is a matter of fact. It therefore does not come as a surprise that an energy conversion system such as a wind turbine, which in particular operates under non-stationary conditions, is subjected to performance decline with age. The present study presents an analysis of the performance deterioration with age of a Vestas V52 wind turbine, installed in 2005 at the Dundalk Institute of Technology campus in Ireland. The wind turbine has operated from October 2005 to October 2018 with its original gearbox, that has subsequently been replaced in 2019. Therefore, a key point of the present study is that operation data spanning over thirteen years have been analysed for estimating how the performance degrades in time. To this end, one of the most innovative approaches for wind turbine performance control and monitoring has been employed: a multivariate Support Vector Regression with Gaussian Kernel, whose target is the power output of the wind turbine. Once the model has been trained with a reference data set, the performance degradation is assessed by studying how the residuals between model estimates and measurements evolve. Furthermore, a power curve analysis through the binning method has been performed to estimate the Annual Energy Production variations and suggests that the most convenient strategy for the test case wind turbine (running the gearbox until its end of life) has indeed been adopted. Summarizing, the main results of the present study are as follows: over a ten-year period, the performance of the wind turbine has declined of the order of 5%; the performance deterioration seems to be nonlinear as years pass by; after the gearbox replacement, a fraction of performance deterioration has been recovered, though not all because the rest of the turbine system has been operating for thirteen years from its original state. Finally, it should be noted that the estimate of performance decline is basically consistent with the few results available in the literature.
Two papers recently published in Science have shown that there is more absorption of solar radiation than estimated by current atmospheric general circulation models (GCMs) and that the discrepancy is associated with cloudy scenes. We have devised a simple model which explains this as an artifact of stochastic radiative transport.
A newly developed numerical model is described which calculates plasma implosion on the Alfvén wave time scale, appropriate for modeling cylindrical pinch experiments. The simulation includes fluid electrons, particle ions, cylindrical geometry, and self-consistent plasma turbulence effects on the resistivity and the ion and electron heating. A series of trial runs is presented to document the effect of including or neglecting turbulent ion heating and cylindrical geometry in the model.
Cascade air-to-water heat pumps have better overall efficiency than single-stage airto-water heat pumps when operating at low ambient temperatures for high temperature water supply. While many studies in the literature investigated the specific features of equipment performance of cascade heat pumps, there is little information about retrofit applications of these heat pumps in residential buildings using experimentally validated dynamic building simulations. In this study, the techno-economic assessment of a variable capacity cascade air-to-water heat pump retrofitted into residential buildings is conducted by means of experimentally validated TRNSYS simulations. The cascade heat pump coupled with thermal energy storage operating in different scenarios is further studied. Laboratory and field trial results were obtained to develop and validate a cascade heat pump model integrated with a dynamic building simulation model. Regarding the heat pump system without storage, the predicted annual COPs were almost below 2.5 at ambient temperatures of from-11.2°C to 29.5°C, even the heat pump adopted weather compensation control. Simulation results also indicated that the cascade heat pump could not defeat gas boilers and high-efficiency oil boilers (90%) in terms of operating costs, but there were CO 2 reductions (from 14% to 57%). As for the heat pump coupled with storage, simulation results showed that at ambient temperatures of between-5.6°C and 23.8°C, the continuous coupling between the heat pump and the storage revealed the lowest annual performance (actual COP of 1.41), while the direct heating obtained the highest efficiency (actual COP of 2.12) followed by the load-shifting (actual COP of 1.88).
It is a common sense expectation that the efficiency of wind turbines should decline with age, similarly to what happens with most technical systems. Due to the complexity of this kind of machine and the environmental conditions to which it is subjected, it is far from obvious how to reliably estimate the impact of aging. In this work, the aging of five Vestas V52 wind turbines is analyzed. The test cases belong to two different sites: one is at the Dundalk Institute of Technology in Ireland, and four are sited in an industrial wind farm in a mountainous area in Italy. Innovative data analysis techniques are employed: the general idea consists of considering appropriate operation curves depending on the working control region of the wind turbines. When the wind turbine operates at fixed pitch and variable rotational speed, the generator speed-power curve is studied; for higher wind speed, when the rotational speed has saturated and the blade pitch is variable, the blade pitch-power curve is considered. The operation curves of interest are studied through the binning method and through a support vector regression with a Gaussian kernel. The wind turbine test cases are analyzed vertically (each in its own history) and horizontally, by comparing the behavior at the two sites for the given wind turbine age. The main result of this study is that an evident effect of aging is the worsening of generator efficiency: progressively, less power is extracted for the given generator rotational speed. Nevertheless, this effect is observed to be lower for the wind turbines in Italy (order of −1.5% at 12 years of age with respect to seven years of age) with respect to the Dundalk wind turbine, which shows a sharp decline at 12 years of age (−8.8%). One wind turbine sited in Italy underwent a generator replacement in 2018: through the use of the same kind of data analysis methods, it was possible to observe that an average performance recovery of the order of 2% occurs after the component replacement. It also arises that for all the test cases, a slight aging effect is visible for higher wind speed, which can likely be interpreted as due to declining gearbox efficiency. In general, it is confirmed that the aging of wind turbines is strongly dependent on the history of each machine, and it is likely confirmed that the technology development mitigates the effect of aging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.