Background: Bronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) has been proven to be effective in patients with severe emphysema. However, the selection of patients without collateral ventilation prior to treatment is critical for procedural success. Collateral ventilation can be assessed directly with the Chartis system or indirectly using computed tomography (CT) fissure analysis. Objectives: We retrospectively evaluated the diagnostic value of a combination of the quantitative CT interlobar fissure completeness score (FCS) and Chartis in predicting responders to EBV therapy. Methods: CT data from four prospective studies were pooled and analyzed using semiautomated software to quantify the completeness of interlobar fissures. These FCSs were compared to a reference standard of achieving ≥350 ml of target lobe volume reduction after EBV treatment. Using a receiver operating characteristic curve, optimal thresholds predictive of complete fissures (responders) and incomplete fissures (non-responders) were determined. A subgroup of patients with partially complete fissures was identified, where software had lower accuracy. The complementary value of Chartis was investigated in this group. Results: A fissure was defined as complete (FCS >95%), incomplete (FCS <80%), or partially complete (80% < FCS < 95%). The positive predictive value (PPV) of complete fissures is 88.1%, and the negative predictive value (NPV) is 92.9%, with an overall accuracy of 89.2%. Chartis was utilized in patients with partially complete fissures, with a PPV of 82.3%, an NPV of 84.6%, and an accuracy of 83.3%. Conclusion: Combining diagnostic tools could reduce the burden on patients and the healthcare system while providing clinicians with a better means for patient selection for EBV therapy.
Background: Endoscopic lung volume reduction with valves is a valid therapeutic option for COPD patients with severe emphysema. The exclusion of interlobar collateral ventilation (CV) is an important predictor of clinical success. Objectives: Recently, a catheter-based endobronchial in vivo measurement system (Chartis, Pulmonx, USA) has become routine in the clinical evaluation of CV status in target lobes, but the criteria for phenotyping CV by Chartis evaluation have not yet been defined. We asked the questions, how many phenotypes can be identified using Chartis, what are the exact criteria to distinguish them, and how do the Chartis phenotypes respond to valve insertionκ Methods: In a retrospective study, 406 Chartis assessments of 166 patients with severe COPD were analyzed. Four Chartis phenotypes, CV positive (CV+), CV negative (CV-), low flow (LF) and low plateau were identified. Fifty-two patients without CV were treated with valves and followed for 3 months. Results: The Chartis phenotypes were discriminated with respect to decline in expiratory peak flow, increase in resistance index and change in total exhaled volume after 1, 2, 3, 4 and 5 min of measurement time (p < 0.0001, ANOVA), and the cutoff criteria were defined accordingly. To examine the application of these phenotyping criteria, students applied them to 100 Chartis assessments, and they demonstrated almost perfect inter- and intraobserver agreements (κ > 0.9). Compared to baseline, CV- and LF patients with ipsilateral CV- lobe showed an improvement in FEV1 (p < 0.05), vital capacity (p < 0.05) and target lobe volume reduction (p < 0.005) after valve insertion. Conclusion: This study describes the most prevalent Chartis phenotypes.
<b><i>Background:</i></b> Bronchoscopic lung volume reduction using endobronchial coils is a new treatment for patients with severe emphysema. To date, the benefits have been modest and have been suggested to be much larger in patients with severe hyperinflation and nonmulti-comorbidity. <b><i>Objective:</i></b> We aimed to evaluate the efficacy and safety of endobronchial coil treatment in a randomized multicenter clinical trial using optimized patient selection. <b><i>Method:</i></b> Patients with severe emphysema on HRCT scan with severe hyperinflation (residual volume [RV] ≥200% predicted and RV/total lung capacity [TLC] >55%) were randomized to coil treatment or control. Primary outcome measures were differences in the forced expiratory volume in 1 s (FEV<sub>1</sub>) and St George’s Respiratory Questionnaire (SGRQ) total score at 6 months. <b><i>Results:</i></b> Due to premature study termination, a total of 120 patients (age 63 ± 7 years, FEV<sub>1</sub> 29 ± 7% predicted, RV 251 ± 41% predicted, RV/TLC 67 ± 6%, and SGRQ 58 ± 13 points), instead of 210 patients, were randomized. At study termination, 91 patients (57 coil and 34 control) had 6-month results available. Analyses showed significantly greater improvements in favor of the coil group. The increase in FEV<sub>1</sub> was greater in the coil group than that in the control group by + 10.3 [+4.7 to +16.0] % and in SGRQ by −10.6 [−15.9 to −5.4] points. At study termination, there were 5 (6.8%) deaths in the coil cohort reported. <b><i>Conclusion:</i></b> Despite early study termination, coil treatment compared to control results in a significant improvement in the lung function and quality of life benefits for up to 6 months in patients with emphysema and severe hyperinflation. These improvements were of clinical importance but were associated with a higher likelihood of serious adverse events.
Purpose Evaluation of emphysema distribution with quantitative computed tomography (qCT) prior to endoscopic lung volume reduction (ELVR) is recommended. The aim of this study was to determine which of the commonly assessed qCT parameters prior to endoscopic lung volume reduction (ELVR) best predicts outcome of treatment.
Materials and Methods 50 patients who underwent technically successful ELVR at our institution were retrospectively analyzed. We performed quantitative analysis of the CT scans obtained prior to ELVR and carried out Mann-Whitney U-tests and a logistic regression analysis to identify the qCT parameters that predict successful outcome of ELVR in terms of improved forced expiratory volume in 1 second (FEV1).
Results In the Mann-Whitney U-test, the interlobar emphysema heterogeneity index (p = 0.008) and the pulmonary emphysema score (p = 0.022) showed a statistically significant difference between responders and non-responders. In multiple logistic regression analysis only the interlobar emphysema heterogeneity index (p = 0.008) showed a statistically significant impact on the outcome of ELVR, while targeted lobe volume, total lung volume, targeted lobe emphysema score and total lung emphysema score did not.
Conclusion Of all commonly assessed quantitative CT parameters, only the heterogeneity index definitely allows prediction of ELVR outcome in patients with advanced chronic obstructive pulmonary disease (COPD).
Key Points
Citation Format
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.