Objectives: To demonstrate reduction in detrusor overactivity using surface electrical stimulation of posterior tibial nerve (PTN) or dorsal penile nerve (DPN) in patients with spinal cord injury (SCI). Design: Patients with SCI with symptoms of urinary urgency/leaks, with cystometrogram (CMG) proven detrusor overactivity were recruited in this study. Ten persons with observable F-wave from tibial nerve were included in the PTN group. Five persons who had F-wave absent but preserved bulbocavernosus reflex were included in the DPN group. Stimulation was given at 20 Hz, 10-40 mA for 20 minutes/session/day for 14 consecutive days. Detrusor overactivity was recorded using CMG on days 1 and 15. Settings: Rehabilitation Institute, Department of Physical Medicine and Rehabilitation, Christian Medical College and Hospital, Vellore, TN, India. Participants: Patients with SCI. Interventions: Surface stimulation of peripheral nerves for reduction of detrusor overactivity. Outcome measures: Qualitative analysis using voiding diary data and quantitative analysis using CMG data comparing pre-and post-intervention. Results: P value obtained from voiding chart was 0.021 for PTN and 0.062 for DPN. P value obtained from CMG data was not significant in both groups. In one subject, treatment was extended to 4 weeks and further improvement in voiding diary was seen. Conclusions: In this pilot study of 15 patients, voiding chart data showed statistically significant improvement following PTN stimulation and trend of improvement following DPN stimulation. However, the CMG data were not statistically significant in this sample population. Further studies with larger, appropriately powered sample size would be helpful to demonstrate the associations of symptoms with CMG data.
Wearable inertial sensor-based motion analysis systems are promising alternatives to standard camera-based motion capture systems for the measurement of gait parameters and joint kinematics. These wearable sensors, unlike camera-based gold standard systems, find usefulness in outdoor natural environment along with confined indoor laboratory-based environment due to miniature size and wireless data transmission. This study reports validation of our developed (i-Sens) wearable motion analysis system against standard motion capture system. Gait analysis was performed at self-selected speed on non-disabled volunteers in indoor ( n = 15) and outdoor ( n = 8) environments. Two i-Sens units were placed at the level of knee and hip along with passive markers (for indoor study only) for simultaneous 3D motion capture using a motion capture system. Mean absolute percentage error (MAPE) was computed for spatiotemporal parameters from the i-Sens system versus the motion capture system as a true reference. Mean and standard deviation of kinematic data for a gait cycle were plotted for both systems against normative data. Joint kinematics data were analyzed to compute the root mean squared error (RMSE) and Pearson’s correlation coefficient. Kinematic plots indicate a high degree of accuracy of the i-Sens system with the reference system. Excellent positive correlation was observed between the two systems in terms of hip and knee joint angles (Indoor: hip 3.98° ± 1.03°, knee 6.48° ± 1.91°, Outdoor: hip 3.94° ± 0.78°, knee 5.82° ± 0.99°) with low RMSE. Reliability characteristics (defined using standard statistical thresholds of MAPE) of stride length, cadence, walking speed in both outdoor and indoor environment were well within the “Good” category. The i-Sens system has emerged as a potentially cost-effective, valid, accurate, and reliable alternative to expensive, standard motion capture systems for gait analysis. Further clinical trials using the i-Sens system are warranted on participants across different age groups.
AN ARTICLE by Belušicˇand Zupancˇicˇ(1) described the construction of a finger pulse sensor using a singing greeting card beeper. We felt that this beeper made of piezoelectric material could be easily modified to function as a respiratory belt transducer to monitor respiratory movements. Commercially available respiratory belt transducers, such as Pneumotrace (http:// www.adinstruments.com/products/mlt1132; marketed by AD Instruments), also use such piezoelectric material. After modification, the beeper was attached to the chest using Velcro straps. The strain induced on the piezoelectric material of the beeper by the chest movement produces a corresponding voltage change, which can be recorded by a computer using data-acquisition systems or observed using an oscilloscope. The construction of the respiratory belt transducer is described below. 1 Materials needed. The following materials are needed for the construction of the respiratory belt transducer (Fig.
Objectives:
Suprasacral spinal cord lesions are prone to have neurogenic detrusor overactivity leading to urinary incontinence. Current medical management has known side-effects and often surgical managements are irreversible. Electrical stimulation to modulate spinal reflex pathway having same nerve root as urinary bladder is reported in the literature. This study aimed to reduce detrusor overactivity in patients with spinal cord injury (SCI) using surface electrical stimulation of medial plantar nerve at the sole of foot.
Materials and Methods:
Twenty adults with SCI having episode of at least 1 leak/day due to detrusor overactivity as diagnosed by cystometrogram (CMG), were on clean intermittent catheterization and ankle jerk was present consented for the study. Participants were asked to maintain bladder diary a week before and during 2 weeks of treatment. CMG was done on day-0 and day-14. cmcUroModul@tor®, an inhouse developed electrical stimulator was used for ½ h daily for period of 2 weeks. Patient satisfaction feedback questionnaire was taken on completion of treatment. CMG data were analyzed using Wilcoxon signed-ranked test while bladder diary was analyzed using binomial distribution. P < 0.05 was considered as statistically significant. Institutional Review Board (IRB) and ethics committee of Christian Medical College, Vellore, approved the study (CMC/IRB/11061).
Results:
Statistical significant improvement in maximum detrusor pressure (P = 0.03) and cystometric capacity (P = 0.04) was observed. Of 20 subjects, 18 showed improvement in bladder diary.
Conclusion:
Neuromodulation of medial plantar nerve at sole of foot by surface electrical stimulation is non-invasive, cost-effective, and alternative simple treatment modality for urinary incontinence due to detrusor overactivity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.