Respiratory belt transducer constructed using a singing greeting card beeper

Abstract: AN ARTICLE by Belušicˇand Zupancˇicˇ(1) described the construction of a finger pulse sensor using a singing greeting card beeper. We felt that this beeper made of piezoelectric material could be easily modified to function as a respiratory belt transducer to monitor respiratory movements. Commercially available respiratory belt transducers, such as Pneumotrace (http:// www.adinstruments.com/products/mlt1132; marketed by AD Instruments), also use such piezoelectric material. After modification, the beeper was a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(1 citation statement)
references
References 1 publication
(1 reference statement)
0
1
0
Order By: Relevance
“…This method of measuring respiratory activity is generally considered to have a relatively low frequency response, but this is not thought to be inherently detrimental to polygraph examinations (Baken & Orlikoff, 2000). One available alternative are piezoelectric respiration transducers, which replace the pneumonic rubber bellows with belts that include stretch-sensors, which function based on the property of certain materials, such as crystals, to build up electrical charges (piezoelectricity) when exposed to mechanical stress (Bhaskar, Subramani, & Ojha, 2013). In either case, the acquired measurements of thoracic and abdominal breathing are usually combined (either on paper or by a digitized polygraph) to create a single composite measure of respiration line length for the examiner (Kircher & Raskin, 2002).…”
Section: Polygraph Technologymentioning
confidence: 99%
“…This method of measuring respiratory activity is generally considered to have a relatively low frequency response, but this is not thought to be inherently detrimental to polygraph examinations (Baken & Orlikoff, 2000). One available alternative are piezoelectric respiration transducers, which replace the pneumonic rubber bellows with belts that include stretch-sensors, which function based on the property of certain materials, such as crystals, to build up electrical charges (piezoelectricity) when exposed to mechanical stress (Bhaskar, Subramani, & Ojha, 2013). In either case, the acquired measurements of thoracic and abdominal breathing are usually combined (either on paper or by a digitized polygraph) to create a single composite measure of respiration line length for the examiner (Kircher & Raskin, 2002).…”
Section: Polygraph Technologymentioning
confidence: 99%