Fault current magnitude in a microgrid depends upon its mode of operation, namely, grid-connected mode or islanded mode. Depending on the type of fault in a given mode, separate protection schemes are generally employed. With the change in microgrid operating mode, the protection scheme needs to be modified which is uneconomical and time inefficient. In this paper, a novel optimal protection coordination scheme is proposed, one which enables a common optimal relay setting which is valid in both operating modes of the microgrid. In this context, a common optimal protection scheme is introduced for dual setting directional overcurrent relays (DOCRs) using a combination of various standard relay characteristics. Along with the two variables, i.e., time multiplier setting (TMS) and plug setting (PS) for conventional directional overcurrent relay, dual setting DOCRs are augmented with a third variable of relay characteristics identifier (RCI), which is responsible for selecting optimal relay characteristics from the standard relay characteristics according to the IEC-60255 standard. The relay coordination problem is formulated as a mixed-integer nonlinear programming (MINLP) problem, and the settings of relays are optimally determined using the genetic algorithm (GA) and the grey wolf optimization (GWO) algorithm. To validate the superiority of the proposed protection scheme, the distribution parts of the IEEE-14 and IEEE-30 bus benchmark systems are considered.
The operating time of directional overcurrent relays (DOCRs) can be reduced with user-defined relay characteristics considering plug setting (PS), time multiplier setting (TMS), and relay characteristic coefficients (λ and γ). This study presents a comparative analysis of relay coordination with standard and user-defined relay characteristics. The proposed relay coordination scheme is formulated as a non-linear constraint optimization problem. The grey wolf optimization (GWO) algorithm is used to determine the optimal relay settings and total operating time of DOCRs. The performance of the proposed scheme is tested on the standard 8-bus, 9-bus, and 15-bus systems. The results show that the total operating time of DOCRs with user-defined relay characteristics is better than that with standard relay characteristics. The results of the GWO algorithm are compared with the performance of optimization techniques used in literature to solve the relay coordination problem.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.