We consider a schematic human eye with four centered aspheric surfaces. We show that by introducing recent experimental average measurements of cornea and lens into the Gullstrand-Le Grand model, the average spherical aberration of the actual eye is predicted without any shape fitting. The chromatic dispersions are adjusted to fit the experimentally observed chromatic aberration of the eye. The polychromatic point-spread function and modulation transfer function are calculated for several pupil diameters and show good agreement with previous experimental results. Finally, from this schematic eye an accommodation-dependent model is proposed that reproduces the increment of refractive power of the eye during accommodation. The variation of asphericity with accommodation is also introduced in the model and the resulting optical performance studied.
We study the dynamics of small vortex clusters with few (2-4) co-rotating vortices in Bose-Einstein condensates by means of experiments, numerical computations, and theoretical analysis. All of these approaches corroborate the counter-intuitive presence of a dynamical instability of symmetric vortex configurations. The instability arises as a pitchfork bifurcation at sufficiently large values of the angular momentum that induces the emergence and stabilization of asymmetric rotating vortex configurations. The latter are quantified in the theoretical model and observed in the experiments. The dynamics is explored both for the integrable two-vortex system, where a reduction of the phase space of the system provides valuable insight, as well as for the non-integrable three-(or more) vortex case, which additionally admits the possibility of chaotic trajectories.
A schematic eye model based on anatomical data, which had been previously designed to reproduce image quality on axis, has been transformed into a wide-angle model by simply adding a spherical image surface that plays the role of the retina. This model captures the main features of the wide-angle optical design of the human eye with minimum complexity: four conic optical surfaces plus a spherical image surface. Seidel aberrations (spherical aberration, coma, astigmatism, field curvature, and distortion), longitudinal and transverse chromatic aberrations, and overall monochromatic spot diagrams have been computed for this eye model and for field angles ranging from 0 degree to 60 degrees by both finite and third-order ray tracing. The modulation transfer function for each field angle has been computed as well. In each case our results have been compared with average experimental data found in the literature, showing a reasonably good agreement. The agreement between the model and experimental data is better off axis, mainly at moderate (10 degrees-40 degrees) field angles, than on axis. The model has been applied to simulate a variety of experimental methods in which image aberrations are estimated from measurements taken in the object space. Our results suggest that for some types of aberration, these methods may yield biased estimates.
Abstract-Image compression systems commonly operate by transforming the input signal into a new representation whose elements are independently quantized. The success of such a system depends on two properties of the representation. First, the coding rate is minimized only if the elements of the representation are statistically independent. Second, the perceived coding distortion is minimized only if the errors in a reconstructed image arising from quantization of the different elements of the representation are perceptually independent. We argue that linear transforms cannot achieve either of these goals, and propose instead an adaptive non-linear image representation in which each coefficient of a linear transform is divided by a weighted sum of coefficient amplitudes in a generalized neighborhood. We then show that the divisive operation greatly reduces both the statistical and the perceptual redundancy amongst representation elements. We develop an efficient method of inverting this transformation, and we demonstrate through simulations that the dual reduction in dependency can greatly improve the visual quality of compressed images.
The depth-of-field (DOF) measured through psychophysical methods seems to depend on the target's characteristics. We use objective and subjective methods to determine the DOF of the eye for different pupil diameters and wavelengths in three subjects. Variation of image quality with focus is evaluated with a double-pass technique. Objective DOF is defined as the dioptric range for which the image quality does not change appreciably, based on optical criteria. Subjective DOF is based on the accuracy of focusing a point source. Additional DOFs are obtained by simulation from experimental wavefront aberration data from the same subjects. Objective and subjective measurements of DOF are only slightly affected by pupil size, wavelength and spectral composition. Comparison of DOF from double-pass and wavefront aberration data allows us to evaluate the role of ocular aberrations and Stiles-Crawford effect.
Several samples of palladium-loaded single-wall carbon nanotubes and palladium-loaded MAXSORB activated carbon were prepared by means of the reaction of the raw carbon support with Pd2(dba)3.CHCl3. When carbon nanotubes were used as the support, the palladium content in the samples reached 13-31 wt % and fine particles of 5-7 nm average size were obtained. In the case of the samples with MAXSORB as the support, the palladium content was higher (30-50 wt %) and the particle size larger (32-42 nm) than in the nanotube samples. At 1 atm and room temperature, the hydrogen capacity of the palladium-loaded samples exceeds 0.1 wt % and is much higher than the capacity of the raw carbon supports (less than 0.01 wt %). The maximum hydrogen capacity at 1 atm and room temperature was found to be 0.5 wt %. A maximum hydrogen capacity of 0.7 wt % was obtained at 90 bar in a palladium-loaded MAXSORB sample, while the capacities for the raw carbon nanotubes and MAXSORB at the same pressure were 0.21 and 0.42 wt %, respectively. At low pressure, it was observed that the H/Pd atomic ratios in the palladium-loaded samples were always higher than in the bulk Pd. The spillover effect is considered as a possible cause of the high H/Pd atomic ratios. On the other hand, the effect of the pressure increase on the spillover was observed to be very low at high pressure and room temperature.
We measured the ocular wavefront aberration at six different visible wavelengths (between 450 and 650 nm) in three subjects, using a spatially resolved refractometer. In this technique, the angular deviation of light rays entering the pupil at different locations is measured with respect to a target viewed through a centered pupil. Fits of the data at each wavelength to Zernike polynomials were used to estimate the change of defocus with wavelength (longitudinal chromatic aberration, LCA) and the wavelength-dependence of the ocular aberrations. Measured LCA was in good agreement with the literature. In most cases the wavefront aberration increased slightly with wavelength. The angular deviations from the reference stimulus measured using a magenta filter allowed us to estimate the achromatic axis and both optical and perceived transverse chromatic aberration (TCA), (including the effect of aberrations and Stiles-Crawford effect). The amount of TCA varied markedly across subjects, and between eyes of the same subject. Finally, we used the results from these experiments to compute the image quality of the eye in polychromatic light.
The retinal image quality characterized by the modulation-transfer function of the eye was measured for two groups of subjects aged in the late twenties and mid sixties, respectively. In both groups, we obtained modulation transfer functions by using a double-pass method under the same experimental conditions: 4-mm artificial pupil, paralyzed accommodation, and objective control of the refractive state and centering. Results showed lower values of modulation in the retinal image for older subjects compared with the younger subjects. The modulation transfer function ratio is similar to that previously found for contrast-sensitivity measurements with subjects in the same age groups. These results suggest that a significant fraction of the loss in spatial vision with age has an optical origin. Apart from the well-known increase in intraocular scattering, there also appears to be an increment in ocular aberration that causes an additional reduction in the contrast of retinal images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.