Background: Remote patient monitoring (RPM) programs in automated peritoneal dialysis (APD) allow clinical teams to be aware of many aspects and events of the therapy that occur in the home. The present study evaluated the association between RPM use and APD technique failure. Methods: A retrospective, multicentre, observational cohort study of 558 prevalent adult APD patients included between 1 October 2016 and 30 June 2017 with follow-up until 30 June 2018 at Renal Therapy Services network in Colombia. Patients were divided into two cohorts based on the RPM use: APD-RPM ( n = 148) and APD-without RPM ( n = 410). Sociodemographic and clinical characteristics of all patients were summarized descriptively. A propensity score was used to create a pseudo-population in which the baseline covariates were well balanced. The association of RPM with technique failure was estimated adjusting for the competing events death and kidney transplant. Results: Five hundred fifty-eight patients were analyzed. 26.5% had APD-RPM. In the matched sample comprising 148 APD-RPM and 148 APD-without RPM patients, we observed a lower technique failure rate of 0.08 [0.05–0.15] episodes per patient-year in APD-RPM versus 0.18 [0.12–0.26] in APD-without RPM cohort; incidence rate ratio = 0.45 95% confidence interval: [0.22–0.91], p-value = 0.03. Conclusions: The use of an RPM program in APD patients may be associated with a lower technique failure rate. More extensive and interventional studies are needed to confirm its potential benefits and to measure other patient-centered outcomes.
<b><i>Introduction:</i></b> A new generation of hemodialysis (HD) membranes called medium cut-off (MCO) membranes possesses enhanced capacities for middle molecule clearance, which have been associated with adverse outcomes in this population. These improvements could potentially positively impact patient-reported outcomes (PROs). <b><i>Objective:</i></b> The objective of this study was to evaluate the impact of MCO membranes on PROs in a cohort of HD patients in Colombia. <b><i>Methods:</i></b> This was a prospective, multicenter, observational cohort study of 992 patients from 12 renal clinics in Colombia who were switched from high-flux HD to MCO therapy and observed for 12 months. Changes in Kidney Disease Quality of Life 36-Item Short Form Survey (KDQoL-SF36) domains, Dialysis Symptom Index (DSI), and restless legs syndrome (RLS) 12 months after switching to MCO membranes were compared with time on high-flux membranes. Repeated measures of ANOVA were used to evaluate changes in KDQoL-SF36 scores; severity scoring was used to assess DSI changes over time; Cochran’s Q test was used to evaluate changes in frequency of diagnostic criteria of RLS. <b><i>Results:</i></b> During 12 months of follow-up, 3 of 5 KDQoL-SF36 domains improved compared with baseline: symptoms (<i>p</i> < 0.0001), effects of kidney disease (<i>p</i> < 0.0001), and burden of kidney disease (<i>p</i> < 0.001). The proportion of patients diagnosed with RLS significantly decreased from 22.1% at baseline to 10% at 12 months (<i>p</i> < 0.0001). No significant differences in the number of symptoms (DSI, <i>p =</i> 0.1) were observed, although their severity decreased (<i>p</i> = 0.009). <b><i>Conclusions:</i></b> In conventional HD patients, the expanded clearance of large middle molecules with MCO-HD membranes was associated with higher health-related quality of life scores and a decrease in the prevalence of RLS.
Expanded hemodialysis (HDx) provides increased clearance of conventional and large middle molecules through innovative medium cutoff (MCO) membranes. However, there is a paucity of real‐world data regarding the benefits and safety of HDx. This large observational study evaluated outcomes among patients in Colombia undergoing HDx at a extended dialysis clinical services provider. This was a prospective single cohort study of prevalent patients who were treated with HDx; baseline information was collected from the most recent data before patients were started on HDx. Patients were followed prospectively for 1 year for changes in serum albumin and other laboratory parameters compared with the baseline. Survival, hospitalization and safety were assessed from the start of HDx. A total of 1000 patients were invited to enroll; 992 patients met the inclusion criteria for data analysis and 638 patients completed the year of follow‐up. Seventy‐four (8%) patients died during 866 patient‐years (PY) of follow‐up; the mortality rate was 8.54 deaths/100 PY (95% confidence interval [CI], 6.8‐10.7). There were 673 hospitalization events with a rate of 0.79 events/PY (95% CI, 0.73‐0.85) with 6.91 hospital days/PY (95% CI, 6.74‐7.09). The observed variability from baseline and maximum average change in mean serum albumin levels were −1.8% and −3.5%, respectively. No adverse events were related to the MCO membrane. HDx using an MCO membrane maintains stable serum albumin levels and is safe in terms of nonoccurrence of dialyzer related adverse events.
Technique failure in peritoneal dialysis (PD) remains one of the most critical challenges of this therapy and is associated with a significant increase in costs and morbidity. Our objective was to estimate the frequency of PD technique failure and identify factors associated with technique failure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.