The aim of this study was verify the biological efficacy of the use of a xenograft for bone loss therapy. Blood clot, particulate autogenous bone or anorganic bovine xenograft filled critical size defects (CSD) in rat calvaria (8mm diameter). After 0, 7, 30 and 90 days the animals were killed and macroscopic, radiographic and histopathological analysis were conducted. Although no treatment promoted the total closure of bone defect, autogenous bone group had better bone repair after 90 days, followed by xenograft group that exhibited direct bone neoformation onto, and around, the particles confirming its osteoconductivity. In conclusion, the xenograft tested in vivo showed biocompatibility, biodegradability and osteoconductive properties in rat calvaria CSD.
; Cresus Vinícius Depes de GOUVÊA 4 A restauração dos dentes tratados endodonticamente, com grande fragilidade de suas estruturas, traz dúvidas ao clínico quanto à melhor forma de atuar nesses elementos. Os retentores intrarradiculares, sejam núcleos metálicos fundidos ou pré-fabricados, são geralmente necessários para a restauração destes elementos. Cada um desses materiais imprime uma força diferente nas estruturas adjacentes, sendo o entendimento destas uma necessidade para a melhor escolha e aplicação clínica do retentor. Objetivo: A proposta do presente trabalho é analisar e avaliar a distribuição de tensões no complexo dente-periodonto pelo método dos elementos finitos bidimensional com a utilização de diferentes tipos de retentores. Método: Este estudo tem por base modelos matemáticos de um canino superior tratado endodonticamente com a utilização de retentores intrarradiculares metálicos fundidos em NiCr, metálicos pré-fabricados em titânio. Os modelos foram submetidos a uma carga de 100 N por palatina em um ângulo de 45º. A análise e avaliação das tensões foram realizadas para cada um dos modelos e seus diferentes tipos de pinos. Resultados: A maior concentração de tensões se deu com o uso do pino metálico pré-fabricado de titânio, com valores de tração que oscilam entre 1.207 MPa a 4.878 MPa e de compressão entre -9.806 MPa a -2.464 MPa. O pino metálico fundido imprimiu tensões de menores valores, mais homogêneas e uniformes, tendo seus valores de tração variando de 1.287 MPa a 4.919 Mpa e seus valores de compressão variando de -9.607 MPa a 2.344 Mpa. Conclusão: Os pinos intrarradiculares metálicos pré-fabricados de titânio geram forte estresse no sistema dente-periodonto, sendo o menos indicado clinicamente. O mais indicado para uso clínico foi o pino metálico fundido, cuja tensão se manifestou de maneira mais uniforme no elemento dentário.Biomecânica; Propriedades físicas; Técnica para retentor intrarradicular.The restoration of endodontically treated teeth with great structure fragility challenges the clinician about the best way to proceed on these elements. The use of intracanal retainers, either post and core systems of prefabricated posts, is usually necessary to restore this kind of teeth. Each one of these materials exerts a different force on the adjacent structures and understanding these forces is mandatory for a better choice and clinical application of intracanal retainers. Objective: The purpose of this study was to analyze and evaluate the stress distribution in the tooth-periodontium complex by the twodimensional finite element method, using different types of retainers. Methods: This study was based on mathematical models of an endodontically treated maxillary canine, using a NiCr cast intracanal posts and a prefabricated titanium post. The models were subjected to a 100 N load directed palatally at a 45º angle. The strains for each of the models and different types of post were analyzed and evaluated. Biomechanics; Physical properties; Post and core technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.