Exoskeletons and active prostheses promise to enhance human mobility, but few have succeeded. Optimizing device characteristics on the basis of measured human performance could lead to improved designs. We have developed a method for identifying the exoskeleton assistance that minimizes human energy cost during walking. Optimized torque patterns from an exoskeleton worn on one ankle reduced metabolic energy consumption by 24.2 ± 7.4% compared to no torque. The approach was effective with exoskeletons worn on one or both ankles, during a variety of walking conditions, during running, and when optimizing muscle activity. Finding a good generic assistance pattern, customizing it to individual needs, and helping users learn to take advantage of the device all contributed to improved economy. Optimization methods with these features can substantially improve performance.
Techniques proposed for assisting locomotion with exoskeletons have often included a combination of active work input and passive torque support, but the physiological effects of different assistance techniques remain unclear. We performed an experiment to study the independent effects of net exoskeleton work and average exoskeleton torque on human locomotion. Subjects wore a unilateral ankle exoskeleton and walked on a treadmill at 1.25 m·s(-1) while net exoskeleton work rate was systematically varied from -0.054 to 0.25 J·kg(-1)·s(-1), with constant (0.12 N·m·kg(-1)) average exoskeleton torque, and while average exoskeleton torque was systematically varied from approximately zero to 0.18 N·m·kg(-1), with approximately zero net exoskeleton work. We measured metabolic rate, center-of-mass mechanics, joint mechanics, and muscle activity. Both techniques reduced effort-related measures at the assisted ankle, but this form of work input reduced metabolic cost (-17% with maximum net work input) while this form of torque support increased metabolic cost (+13% with maximum average torque). Disparate effects on metabolic rate seem to be due to cascading effects on whole body coordination, particularly related to assisted ankle muscle dynamics and the effects of trailing ankle behavior on leading leg mechanics during double support. It would be difficult to predict these results using simple walking models without muscles or musculoskeletal models that assume fixed kinematics or kinetics. Data from this experiment can be used to improve predictive models of human neuromuscular adaptation and guide the design of assistive devices.
The goal of this study was to gain insight into how ankle exoskeletons affect the behavior of the plantarflexor muscles during walking. Using data from previous experiments, we performed electromyographydriven simulations of musculoskeletal dynamics to explore how changes in exoskeleton assistance affected plantarflexor muscletendon mechanics, particularly for the soleus. We used a model of muscle energy consumption to estimate individual muscle metabolic rate. As average exoskeleton torque was increased, while no net exoskeleton work was provided, a reduction in tendon recoil led to an increase in positive mechanical work performed by the soleus muscle fibers. As net exoskeleton work was increased, both soleus muscle fiber force and positive mechanical work decreased. Trends in the sum of the metabolic rates of the simulated muscles correlated well with trends in experimentally observed whole-body metabolic rate (R 2 =0.9), providing confidence in our model estimates. Our simulation results suggest that different exoskeleton behaviors can alter the functioning of the muscles and tendons acting at the assisted joint. Furthermore, our results support the idea that the series tendon helps reduce positive work done by the muscle fibers by storing and returning energy elastically. We expect the results from this study to promote the use of electromyography-driven simulations to gain insight into the operation of muscle-tendon units and to guide the design and control of assistive devices.
Exoskeletons have the potential to assist and augment human performance. Understanding how users adapt their movement and neuromuscular control in response to external assistance is important to inform the design of these devices. The aim of this research was to evaluate changes in muscle recruitment and coordination for ten unimpaired individuals walking with an ankle exoskeleton. We evaluated changes in the activity of individual muscles, cocontraction levels, and synergistic patterns of muscle coordination with increasing exoskeleton work and torque. Participants were able to selectively reduce activity of the ankle plantarflexors with increasing exoskeleton assistance. Increasing exoskeleton net work resulted in greater reductions in muscle activity than increasing exoskeleton torque. Patterns of muscle coordination were not restricted or constrained to synergistic patterns observed during unassisted walking. While three synergies could describe nearly 95% of the variance in electromyography data during unassisted walking, these same synergies could describe only 85-90% of the variance in muscle activity while walking with the exoskeleton. Synergies calculated with the exoskeleton demonstrated greater changes in synergy weights with increasing exoskeleton work versus greater changes in synergy activations with increasing exoskeleton torque. These results support the theory that unimpaired individuals do not exclusively use central pattern generators or other low-level building blocks to coordinate muscle activity, especially when learning a new task or adapting to external assistance, and demonstrate the potential for using exoskeletons to modulate muscle recruitment and coordination patterns for rehabilitation or performance.
Abstract-Lower-limb exoskeletons that can comfortably apply high torques at high bandwidth can be used to probe the human neuromuscular system and assist gait. We designed and built two tethered ankle-foot exoskeletons with strong lightweight frames, comfortable three-point contact with the leg, and series elastic elements for improved torque control. Both devices have low mass (< 0.87 kg), are modular and structurally compliant in selected directions, and are instrumented to measure joint angle and torque. The exoskeletons are actuated by an offboard motor, and torque is controlled using a combination of proportional feedback, damping injection and iterative learning. We tested closed-loop torque control by commanding 50 N·m and 20 N·m linear chirps in desired torque while the exoskeletons were worn by human users, and measured bandwidths greater than 16 Hz and 21 Hz, respectively. During walking trials, we demonstrated 120 N·m peak torque and 2.0 N·m RMS torque tracking error. These performance measures compare favorably with previous devices and with human ankle musculature, and show that these exoskeletons can be used to rapidly explore a wide range of control techniques and robotic assistance paradigms as elements of versatile, high-performance testbeds. Our results also provide insights into desirable properties of lower-limb exoskeleton hardware, which we expect to inform future designs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.