Postoperative acute renal failure after thoracoabdominal and total descending thoracic aortic aneurysm surgery is associated with preoperative creatinine level, visceral perfusion, left renal artery reattachment, and simple cross-clamp technique.
The accuracy of transrectal ultrasound used as a routine clinical examination in rectal carcinoma patients was clearly lower than that reported in the literature. We conclude that TRUS may aid decisions relevant to treatment only when used by well-trained investigators with a large case load of rectal carcinoma patients. Centralization of transrectal ultrasonography service is mandatory if a high level of quality is to be achieved with this method.
Surgical quality control in the form of prospective multicentre observational studies make possible the analysis of the therapeutic situation of a surgical disease under quality assurance aspects. At the same time, the comprehensive data material available will serve the specific planning of prospective randomized studies. With the aid of the present study, a basis for a thorough and complete evaluation of colorectal carcinoma has been created.
In the elderly, locally advanced tumors, but not metastasizing tumors, are to be expected. The increase in postoperative morbidity and mortality rates with increasing age was due to the increase in general postoperative complications. Surgery for colorectal carcinoma in patients of advanced age is not associated with any increase in intraoperative or specific postoperative complications.
This prospective multicenter study investigated the effect of hospital caseload on early postoperative outcome of surgery for carcinoma of the colon in 75 German hospitals and included 2293 patients. The hospitals were divided into those with a caseload of 1-30 (group A), 31-60 (group B), and more than 60 (group C) operations. Increasing caseload was associated only with fewer general postoperative complications. It was also associated with significantly greater use of antibiotic prophylaxis. No significant differences between the groups were found in resection rates, intraoperative complications, specific postoperative complications, overall postoperative morbidity, hospital mortality, or 30-day mortality. The significance of hospital caseload for the short-term postoperative outcome following surgery on the colon should not be overestimated. Basing conclusions about the results to be expected simply on the case volume is impermissible. On the basis of the available data it is not possible to establish a threshold value, that is, a minimum number of required operations.
Implanted biomaterials trigger acute and chronic inflammatory responses directly correlated to the central role of phagocytic cells at the host-implant interface. This study was designed to evaluate specific humoral immune responses following repeated intraperitoneal implantations of collagen-impregnated polyester (Dacron) prosthetic segments into LEWIS rats. Serum antibody detection was performed by enzyme immunoassay with the prosthetic segments as a target. Cutoff values for antibody positivity were greater than or equal to the 99th percentile for control rats. Polymer immunoglobiulin G (IgG) antibodies were significantly increased (p < 0.05) by repeated implantation and were subsequently followed until experimental day 293. Antibody formation was significantly enhanced through the application of complete Freund's adjuvant in combination with the first implantation. All rats within this group were antibody-positive on day 53, but only 6 of 10 animals that received the prosthesis without the adjuvant were. After preincubation of sera with bovine collagen type I (solid phase adsorbed or in solution), polymer antibody binding was discovered not to be diminished, indicating that the IgG antibodies detected were not directed against the prosthesis impregnation. Furthermore, a significant correlation was obtained between polymer antibody binding to collagen-impregnated and nonimpregnated prostheses (r(s) = 0.797, p < 0.001). There was no substantiated correlation between antibody binding to polyester and to an irrelevant polymer (Tecoflex EG 80). We conclude that specific polymer antibodies may indeed provide an additional parameter for biocompatibility testing as well as a possible serological marker of an inflammatory response to implants.
We investigated a polyester vascular prosthesis (PET) coated with elemental silver (SC). Measurement of silver release over a period of 52 weeks by means of inductively coupled plasma atomic emission spectrometry of PET with (PET-G) and without (PET-N) gelatine impregnation revealed a silver release on the first day of 1.2 +/- 0.2 microg (PET-N) and 1.2 +/- 0.1 microg (PET-G) (calculated for 1 g of prosthesis); from the 90th day onward, it was between 0.22 +/- 0.14 microg (PET-N) and 0.18 +/- 0.12 microg (PET-G) per day. The prostheses were incubated with Staphylococcus aureus (S.a.), Staphylococcus epidermidis (S.e.), or Escherichia coli (E.c.) to investigate in vitro antibacterial efficacy. After 6 h of incubation, no colony-forming units were to be seen for any of the bacterial suspensions for PET with SC (p < 0.001). To investigate in vivo antibacterial efficacy, PET-G rings with and without SC contaminated with S.a., S.e., or E.c. were implanted in 18 albino rabbits and examined 7 days after agar culture for 48 h. The silver coating was associated with a significant reduction in bacterial growth (S.a., p = 0.001; S.e., p < 0.005; E.c., p < 0.001). The silver-coated prosthesis, with and without gelatine impregnation, had a significantly antibacterial effect with continuous release of silver.
Besides inflammation, specific immune responses are seen also after implantation of biomaterials. The aim was to investigate the humoral response to bovine collagen type I following implantation of various polyester (Dacron) prostheses into pigs. In 24 randomized pigs, the infrarenal aorta was replaced with a segment of collagen-impregnated, woven polyester prosthesis of low, medium, or high porosity. IgG antibodies were detected by immunoassay using native and denatured collagen type I as a target for blood samples taken on day 1 (implantation), 10, 17, 24, 62, and 116. As generally observed, antibodies to native and denatured collagen are of low titer and were significantly correlated with enhanced binding to the denatured form (p < 0.001). The highest overall antibody prevalence to native and denatured collagen was obtained on day 116 with 68% and on day 62 with 59%, respectively. Prostheses with high porosity induced an early immune response on day 10; those with low and medium porosity induced the highest antibody levels later after 2 months. Collagen antibodies neither correlated with serum IgG contents nor with antibodies to the prosthesis polyester matrix. Thus, humoral immune response against implant components may provide a further parameter in describing biocompatibility but also a potential marker that may facilitate monitoring of individual perigraft reaction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.