a b s t r a c tWe have been developing a novel radiation-tolerant n þ -in-p silicon microstrip sensor for very high radiation environments, aiming for application in the high luminosity large hadron collider. The sensors are fabricated in 6 in., p-type, float-zone wafers, where large-area strip sensor designs are laid out (Y. Unno).Nuclear Instruments and Methods in Physics Research A 765 (2014) 80-90 n þ -in-p P-type Radiation-tolerant HL-LHC PTP together with a number of miniature sensors. Radiation tolerance has been studied with ATLAS07 sensors and with independent structures. The ATLAS07 design was developed into new ATLAS12 designs. The ATLAS12A large-area sensor is made towards an axial strip sensor and the ATLAS12M towards a stereo strip sensor. New features to the ATLAS12 sensors are two dicing lines: standard edge space of 910 μm and slim edge space of 450 μm, a gated punch-through protection structure, and connection of orphan strips in a triangular corner of stereo strips. We report the design of the ATLAS12 layouts and initial measurements of the leakage current after dicing and the resistivity of the wafers.
PMMA_TPE_RED polymers containing 0.98–3.05 wt% of a red-emitting AIEgen were prepared and proposed as high performance luminescent solar concentrators.
Ultrasound contrast agents (UCA) populations are typically polydisperse and contain microbubbles with radii over a given range. Although the behavior of microbubbles of certain sizes might be masked by the behavior of others, the acoustic characterization of UCA is typically made on full populations. In this paper, we have combined acoustic and optical methods to investigate the response of isolated lipid-shelled microbubbles to low-pressure (49 and 62 kPa peak negative pressure) ultrasound tone bursts. These bursts induced slow deflation of the microbubbles. The experimental setup included a microscope connected to a fast camera acquiring one frame per pulse transmitted by a single-element transducer. The behavior of each bubble was measured at multiple frequencies, by cyclically changing the transmission frequency over the range of 2 to 4 MHz during subsequent pulse repetition intervals. The bubble echoes were captured by a second transducer and coherently recorded. More than 50 individual microbubbles were observed. Microbubbles with radii larger than 3 mum did not experience any size reduction. Smaller bubbles slowly deflated, generally until the radius reached a value around 1.4 microm, independent of the initial microbubble size. The detected pressure amplitude backscattered at 2.5 cm distance was very low, decreasing from about 5 Pa down to 1 Pa at 2 MHz as the bubbles deflated. The resonant radius was evaluated from the echo amplitude normalized with respect to the geometrical cross section. At 2-MHz excitation, deflating microbubbles showed highest normalized echo when the radius was 2.2 microm while at higher excitation frequencies, the resonant radius was lower. The relative phase shift of the echo during the deflation process was also measured. It was found to exceed pi/2 in all cases. A heuristic procedure based on the analysis of multiple bubbles of a same population was used to estimate the undamped natural frequency. It was found that a microbubble of 1.7 microm has an undamped natural frequency of 2 MHz. The difference between this size and the resonant radius is discussed as indicative of significant damping.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.