A comparative evaluation of the following commercial immunoassays for the determination of antibodies to Toxoplasma gondii was performed: Behring Diagnostics OPUS Toxo G and Toxo M, Abbott Diagnostics IMX Toxo-IgG 2.0 and Toxo-IgM, Sanofi Diagnostics Pasteur Platelia Toxo IgG and Toxo IgM, and bioMérieux Vitek VIDAS Toxo IgG and IgM. Of 676 specimens that were tested for Toxoplasma-specific immunoglobulin G (IgG) antibodies, 26% were reactive by all methods while 8% displayed some discrepancy. Of 718 specimens that were tested for Toxoplasma-specific IgM antibodies, 3% were reactive by all methods while 10% displayed some discrepancy. Analysis of discrepant specimens revealed performance shortcomings with all IgM-specific assays. The impact of such shortcomings is magnified in a population with a low prevalence of toxoplasmosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.