Based on an experimental database consisting of 194 daily cases, artificial neural networks were used to model the removal efficiency of a biofilter for treating hydrogen sulphide (H2S). In this work, the removal efficiency of the reactor was considered as a function of the changes in the air flow and concentration of H2S entering the biofilter. In order to obtain true representative values, the removal efficiencies (outputs) were measured 24 h after each input was changed. A MLP (multilayer perceptron 2-2-1) model with two input variables (unit flow and concentration of the contaminant fed into the biofilter) rendered good prediction values with a determination coefficient of 0.92 for the removal efficiency within the range studied. This means that the MLP model can explain 92% of the overall variability detected in the biofilter corresponding to a wide range of operating conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.