The development of spectral X-ray computed tomography (CT) using binned photon-counting detectors has received great attention in recent years and has enabled selective imaging of contrast agents loaded with K-edge materials. A practical issue in implementing this technique is the mitigation of the high-noise levels often present in material-decomposed sinogram data. In this work, the spectral X-ray CT reconstruction problem is formulated within a multi-channel (MC) framework in which statistical correlations between the decomposed material sinograms can be exploited to improve image quality. Specifically, a MC penalized weighted least squares (PWLS) estimator is formulated in which the data fidelity term is weighted by the MC covariance matrix and sparsity-promoting penalties are employed. This allows the use of any number of basis materials and is therefore applicable to photon-counting systems and K-edge imaging. To overcome numerical challenges associated with use of the full covariance matrix as a data fidelity weight, a proximal variant of the alternating direction method of multipliers is employed to minimize the MC PWLS objective function. Computer-simulation and experimental phantom studies are conducted to quantitatively evaluate the proposed reconstruction method.
The single-shot compressed ultrafast photography (CUP) camera is the fastest receive-only camera in the world. In this Letter, we introduce an external CCD camera and a space- and intensity-constrained (SIC) reconstruction algorithm to improve the image quality of CUP. The external CCD camera takes a time-unsheared image of the dynamic scene. Unlike the previously used unconstrained algorithm, the proposed algorithm incorporates both spatial and intensity constraints based on the additional prior information provided by the external CCD camera. First, a spatial mask is extracted from the time-unsheared image to define the zone of action. Next, an intensity threshold is determined based on the similarity between the temporally projected image of the reconstructed datacube and the time-unsheared image. Both simulation and experimental studies show that the SIC reconstruction improves the spatial resolution, contrast, and general quality of the reconstructed image.
The development of spectral computed tomography (CT) using binned photon-counting detectors has garnered great interest in recent years and has enabled selective imaging of K-edge materials. A practical challenge in CT image reconstruction of K-edge materials is the mitigation of image artifacts that arise from reduced-view and/or noisy decomposed sinogram data. In this Note, we describe and investigate sparsity-regularized penalized weighted least squares-based image reconstruction algorithms for reconstructing K-edge images from few-view decomposed K-edge sinogram data. To exploit the inherent sparseness of typical K-edge images, we investigate use of a total variation (TV) penalty and a weighted sum of a TV penalty and an ℓ1-norm with a wavelet sparsifying transform. Computer-simulation and experimental phantom studies are conducted to quantitatively demonstrate the effectiveness of the proposed reconstruction algorithms.
Differential X-ray phase-contrast tomography (DPCT) refers to a class of promising methods for reconstructing the X-ray refractive index distribution of materials that present weak X-ray absorption contrast. The tomographic projection data in DPCT, from which an estimate of the refractive index distribution is reconstructed, correspond to one-dimensional (1D) derivatives of the two-dimensional (2D) Radon transform of the refractive index distribution. There is an important need for the development of iterative image reconstruction methods for DPCT that can yield useful images from few-view projection data, thereby mitigating the long data-acquisition times and large radiation doses associated with use of analytic reconstruction methods. In this work, we analyze the numerical and statistical properties of two classes of discrete imaging models that form the basis for iterative image reconstruction in DPCT. We also investigate the use of one of the models with a modern image reconstruction algorithm for performing few-view image reconstruction of a tissue specimen.
The FISTA achieves a quadratic convergence rate and can therefore potentially reduce the number of iterations required to produce an image of a specified image quality as compared to first-order methods. We have proposed and investigated accelerated FISTAs for use with two nonsmooth penalty functions that will lead to further reductions in image reconstruction times while preserving image quality. Moreover, with the help of a mixed sparsity-regularization, better preservation of soft-tissue structures can be potentially obtained. The algorithms were systematically evaluated by use of computer-simulated and clinical data sets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.