Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical valve replacement in high-risk patients afflicted by severe aortic stenosis. Despite newer-generation devices enhancements, post-procedural complications such as paravalvular leakage (PVL) and related thromboembolic events have been hindering TAVR expansion into lower-risk patients. Computational methods can be used to build and simulate patient-specific deployment of transcatheter aortic valves (TAVs) and help predict the occurrence and degree of PVL. In this study finite element analysis and computational fluid dynamics were used to investigate the influence of procedural parameters on post-deployment hemodynamics on three retrospective clinical cases affected by PVL. Specifically, TAV implantation depth and balloon inflation volume effects on stent anchorage, degree of paravalvular regurgitation and thrombogenic potential were analyzed for cases in which Edwards SAPIEN and Medtronic CoreValve were employed. CFD results were in good agreement with corresponding echocardiography data measured in patients in terms of the PVL jets locations and overall PVL degree. Furthermore, parametric analyses demonstrated that positioning and balloon over-expansion may have a direct impact on the post-deployment TAVR performance, achieving as high as 47% in PVL volume reduction. While the model predicted very well clinical data, further validation on a larger cohort of patients is needed to verify the level of the model’s predictions in various patient-specific conditions. This study demonstrated that rigorous and realistic patient-specific numerical models could potentially serve as a valuable tool to assist physicians in pre-operative TAVR planning and TAV selection to ultimately reduce the risk of clinical complications.
TAVR is safe in low-risk patients with symptomatic severe aortic stenosis, with low procedural complication rates, short hospital length of stay, zero mortality, and zero disabling stroke at 30 days. Subclinical leaflet thrombosis was observed in a minority of TAVR patients at 30 days. (Feasibility of Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic, Severe Aortic Stenosis [Low Risk TAVR; NCT02628899).
The first orthogonal combinatorial synthesis of a high-purity triazine library was demonstrated. Novel triazine-based microtubule inhibitors were discovered by an efficient zebrafish embryo screening and in vitro microtubule polymerization assay.
Patients with moderate CKD or ESRD undergoing PCI have an approximately threefold increase in the risk of in-hospital mortality compared with patients with preserved renal function, with radically different mortality predictors existing for varying levels of renal function.
While AMI continues to be a leading cause of mortality in both men and women, significant gender differences exist in presentation, management, and outcomes. Women with AMI are older, suffer atypical symptoms, and more often present with HF and cardiogenic shock. Delays in medical care and hence longer ischemic times exist in women, partly due to decreased awareness and lack of symptom recognition. Women continue to be less likely to receive guideline-based pharmacological therapies and revascularization than men with AMI. While women suffer from significantly higher risk-adjusted rates of bleeding, vascular complications, and short-term mortality, the risk-adjusted rates of long-term mortality remain similar between men and women. Further investigations and efforts are needed to aggressively modify risk factors, reduce delays in care, and address the higher rates of adverse events seen in women with AMI. Significant sex disparities are prevalent in presentation, management, and outcomes of adults with AMI. Further investigations and efforts are needed to aggressively modify risk factors, reduce delays in care, and address the higher rates of adverse events seen in women with AMI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.