2020
DOI: 10.1016/j.jcin.2020.02.008
|View full text |Cite
|
Sign up to set email alerts
|

Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
43
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 86 publications
(50 citation statements)
references
References 15 publications
3
43
0
Order By: Relevance
“…In recent trials it has shown superior outcomes, even in patients with low surgical risk. 43 However, despite the increase in procedural expertise, conduction disturbances, and pacemaker insertion remain major complications following TAVR, with incidence reported to be approximately 7.8%-20.3% in prior studies. 44,45 There have been several studies of post-TAVR PPMI looking for various risk predictors including anatomic, procedural, electrophysiological and demographic factors.…”
Section: Discussionmentioning
confidence: 99%
“…In recent trials it has shown superior outcomes, even in patients with low surgical risk. 43 However, despite the increase in procedural expertise, conduction disturbances, and pacemaker insertion remain major complications following TAVR, with incidence reported to be approximately 7.8%-20.3% in prior studies. 44,45 There have been several studies of post-TAVR PPMI looking for various risk predictors including anatomic, procedural, electrophysiological and demographic factors.…”
Section: Discussionmentioning
confidence: 99%
“…TAVI has evolved to be the standard of care for elderly patients with symptomatic severe AS, with recent research showing benefits across the entire surgical‐risk spectrum 13‐23 . Inspired by the early and ongoing success of TAVI, newer valves and technologies were rapidly introduced incorporating features that could potentially overcome the limitations of earlier devices 24,25 .…”
Section: Discussionmentioning
confidence: 99%
“…Though only 16% under expanded compared to TAV, device placement in this BAV configuration loses axisymmetry with three-fold greater device centroid displacement, between annulus and leaflet free edge, compared to both TAV and Sievers 0 and maximum strut deviation that is three-fold greater than devices deployed in TAV ( Fig 3 ). Such deviations in expansion and alignment are thought to be associated with clinical complications [ 17 20 ]. Indeed, the loss of axisymmetry observed in devices deployed in Sievers 1 BAV, are unlikely to reconstitute normal flow and instead may impose eccentric jets that effect perfusion, which may manifest clinically as higher rates of stroke at 30 days compared to TAV [ 15 ].…”
Section: Discussionmentioning
confidence: 99%