Cochrane Database of Systematic Reviews Data collection and analysis We used standard methods of The Cochrane Collaboration and its Neonatal Review Group, including independent assessment of trial quality and extraction of data by each review author. Main results We included six studies involving 355 infants-two using face mask CPAP, two CNP, one nasal CPAP and one both CNP (for less ill babies) and endotracheal CPAP (for sicker babies). For this update, we included no new trials. Continuous distending pressure (CDP) is associated with lower risk of treatment failure (death or use of assisted ventilation) (typical risk ratio (RR) 0.65, 95% confidence interval (CI) 0.52 to 0.81; typical risk di erence (RD)-0.20, 95% CI-0.29 to-0.10; number needed to treat for an additional beneficial outcome (NNTB) 5, 95% CI 4 to 10; six studies; 355 infants), lower overall mortality (typical RR 0.52, 95% CI 0.32 to 0.87; typical RD-0.15, 95% CI-0.26 to-0.04; NNTB 7, 95% CI 4 to 25; six studies; 355 infants) and lower mortality in infants with birth weight above 1500 g (typical RR 0.24, 95% CI 0.07 to 0.84; typical RD-0.28, 95% CI-0.48 to-0.08; NNTB 4, 95% CI 2.00 to 13.00; two studies; 60 infants). Use of CDP is associated with increased risk of pneumothorax (typical RR 2.64, 95% CI 1.39 to 5.04; typical RD 0.10, 95% CI 0.04 to 0.17; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 17.00 to 25.00; six studies; 355 infants). We found no di erence in bronchopulmonary dysplasia (BPD), defined as oxygen dependency at 28 days (three studies, 260 infants), as well as no di erence in outcome at nine to 14 years (one study, 37 infants). Authors' conclusions In preterm infants with respiratory distress, the application of CDP as CPAP or CNP is associated with reduced respiratory failure and mortality and an increased rate of pneumothorax. Four out of six of these trials were done in the 1970s. Therefore, the applicability of these results to current practice is di icult to assess. Further research is required to determine the best mode of administration.
ImportanceRetinopathy of prematurity (ROP) telemedicine screening programs have been found to be effective, but they rely on widefield digital fundus imaging (WDFI) cameras, which are expensive, making them less accessible in low- to middle-income countries. Cheaper, smartphone-based fundus imaging (SBFI) systems have been described, but these have a narrower field of view (FOV) and have not been tested in a real-world, operational telemedicine setting.ObjectiveTo assess the efficacy of SBFI systems compared with WDFI when used by technicians for ROP screening with both artificial intelligence (AI) and human graders.Design, Setting, and ParticipantsThis prospective cross-sectional comparison study took place as a single-center ROP teleophthalmology program in India from January 2021 to April 2022. Premature infants who met normal ROP screening criteria and enrolled in the teleophthalmology screening program were included. Those who had already been treated for ROP were excluded.ExposuresAll participants had WDFI images and from 1 of 2 SBFI devices, the Make-In-India (MII) Retcam or Keeler Monocular Indirect Ophthalmoscope (MIO) devices. Two masked readers evaluated zone, stage, plus, and vascular severity scores (VSS, from 1-9) in all images. Smartphone images were then stratified by patient into training (70%), validation (10%), and test (20%) data sets and used to train a ResNet18 deep learning architecture for binary classification of normal vs preplus or plus disease, which was then used for patient-level predictions of referral warranted (RW)– and treatment requiring (TR)–ROP.Main Outcome and MeasuresSensitivity and specificity of detection of RW-ROP, and TR-ROP by both human graders and an AI system and area under the receiver operating characteristic curve (AUC) of grader-assigned VSS. Sensitivity and specificity were compared between the 2 SBFI systems using Pearson χ2testing.ResultsA total of 156 infants (312 eyes; mean [SD] gestational age, 33.0 [3.0] weeks; 75 [48%] female) were included with paired examinations. Sensitivity and specificity were not found to be statistically different between the 2 SBFI systems. Human graders were effective with SBFI at detecting TR-ROP with a sensitivity of 100% and specificity of 83.49%. The AUCs with grader-assigned VSS only were 0.95 (95% CI, 0.91-0.99) and 0.96 (95% CI, 0.93-0.99) for RW-ROP and TR-ROP, respectively. For the AI system, the sensitivity of detecting TR-ROP sensitivity was 100% with specificity of 58.6%, and RW-ROP sensitivity was 80.0% with specificity of 59.3%.Conclusions and RelevanceIn this cross-sectional study, 2 different SBFI systems used by technicians in an ROP screening program were highly sensitive for TR-ROP. SBFI systems with AI may be a cost-effective method to improve the global capacity for ROP screening.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.