Background/aim
The purpose of this study is to compare the diagnostic accuracy and interobserver reliability of the T2-weighted 3D-SPACE (three-dimensional sampling perfection with application-optimized contrasts by using different flip angle evolutions) sequence in comparison with T2-weighted 3D-CISS (three-dimensional constructive interference in steady state) sequences for diagnosis of schwannomas.
Materials and methods
Forty patients with cerebellopontine angle (CPA), internal acoustic canal (IAC), and cochlear schwannoma who had undergone magnetic resonance imaging (MRI) using the 3D-CISS and 3D-SPACE sequences were identified. The sequences were retrospectively evaluated by two radiologists for the qualitative analyses, which were subsequently compared using the Mann–Whitney U test. Following this, kappa values were used for interobserver agreement. P < 0.05 was considered to be of statistical significance.
Results
The interobserver agreement was found to be excellent between the two observers for the interpretation of all qualitative analyses for both sequences (kappa value > 0.8). The 3D-SPACE sequences demonstrated significantly better qualitative scores and fewer artifacts compared with the 3D-CISS sequences (p < 0.05).
Conclusion
Our results demonstrate that 3D-SPACE is superior to 3D-CISS in the imaging process of the schwannoma in terms of image quality, description of the relationship between the lesion and cranial nerve, signal differentiation between lesion and cistern, and signal differentiation between the lesion and adjacent brain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.