Several anterior and posterior methods are today available for stabilization of the cervical spine. Factors such as level and degree of instability, method of decompression, bone quality, length of fixation and safety factors influence the choice of method for a particular patient. The use of laminar hooks in the cervical spine has been restricted by fear of cord compression with the potential of tetraplegia. The aim of the present study was to assess the safety and determine the anatomical relation between hooks inserted in the cervical spinal canal and the dura and spinal cord. Thirteen cadavers from seven women and six men with no evidence of cervical spine disorder were included. The mean age was 81.3 years (range 65-101 years). The cervical spine was instrumented with cervical Compact Cotrel Dubousset hooks and rods. The effect of the hook on the dura was studied by myelography in nine cadavers. The deformation of the dural sac was quantified by measurement of the maximal width of the indentation of the contrast column at each level. A CT myelography scan was obtained in three cadavers. The ratio between the distance of maximal hook intrusion into the spinal canal and the canal diameter in the direction of the hook was calculated. The relation between inserted hooks and the spinal cord and dura was documented in a fresh cadaver studied with CT myelography. A hemilaminectomy was performed at all levels in three cadavers with direct visual inspection and photography of the hook sites before and after excision of the dura. A dural deformation of 2 mm or less, as observed by myelography, was found at four out of 77 (5%) hook sites. The deformation was caused by a supralaminar hook at C3, C6 and C7 and by an infralaminar hook at C6. The mean hook intrusion in the spinal canal, as observed on CT, was 27% (range 8-43) of the canal diameter. On visual inspection, 14 out of 18 hooks were in contact with the dura. After removal of the dura, two out of the 18 hooks in the same cadaver were in contact with the spinal cord. However, no deformation of the cord was observed. To our knowledge this is the first study systematically documenting the relation between hooks and the spinal cord in cadavers. In 95% of the hooks no deformation of the dural sac was observed and there was no evidence of spinal cord deformation. From an anatomical point of view, laminar hook instrumentation can be considered a safe procedure. The study shows, however, that hooks inserted in the cervical spine have a close anatomical relationship with the neuraxis, and at stenotic levels the use of other techniques is therefore recommended.
OBJECTIVE
The objective of this paper was to determine the interobserver reliability and intraobserver reproducibility of the AO Spine Upper Cervical Injury Classification System based on surgeon experience (< 5 years, 5–10 years, 10–20 years, and > 20 years) and surgical subspecialty (orthopedic spine surgery, neurosurgery, and "other" surgery).
METHODS
A total of 11,601 assessments of upper cervical spine injuries were evaluated based on the AO Spine Upper Cervical Injury Classification System. Reliability and reproducibility scores were obtained twice, with a 3-week time interval. Descriptive statistics were utilized to examine the percentage of accurately classified injuries, and Pearson’s chi-square or Fisher’s exact test was used to screen for potentially relevant differences between study participants. Kappa coefficients (κ) determined the interobserver reliability and intraobserver reproducibility.
RESULTS
The intraobserver reproducibility was substantial for surgeon experience level (< 5 years: 0.74 vs 5–10 years: 0.69 vs 10–20 years: 0.69 vs > 20 years: 0.70) and surgical subspecialty (orthopedic spine: 0.71 vs neurosurgery: 0.69 vs other: 0.68). Furthermore, the interobserver reliability was substantial for all surgical experience groups on assessment 1 (< 5 years: 0.67 vs 5–10 years: 0.62 vs 10–20 years: 0.61 vs > 20 years: 0.62), and only surgeons with > 20 years of experience did not have substantial reliability on assessment 2 (< 5 years: 0.62 vs 5–10 years: 0.61 vs 10–20 years: 0.61 vs > 20 years: 0.59). Orthopedic spine surgeons and neurosurgeons had substantial intraobserver reproducibility on both assessment 1 (0.64 vs 0.63) and assessment 2 (0.62 vs 0.63), while other surgeons had moderate reliability on assessment 1 (0.43) and fair reliability on assessment 2 (0.36).
CONCLUSIONS
The international reliability and reproducibility scores for the AO Spine Upper Cervical Injury Classification System demonstrated substantial intraobserver reproducibility and interobserver reliability regardless of surgical experience and spine subspecialty. These results support the global application of this classification system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.