Background: Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE), it is still used as an adjunct to coronary artery bypass grafting (CABG). This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed.
BackgroundCardiac tamponade is a severe complication after open heart surgery. Diagnostic imaging is challenging in postoperative patients, especially if tamponade develops with subacute symptoms. Hypothesizing that delayed tamponade after open heart surgery is not sufficiently detected by transthoracic echocardiography, in this study CT scans were used as standard reference and were compared with transthoracic echocardiography imaging in patients with suspected cardiac tamponade.MethodTwenty-five patients after open heart surgery were enrolled in this analysis. In case of suspected cardiac tamponade patients underwent both echocardiography and CT imaging. Using CT as standard of reference sensitivity, specificity, positive and negative predictive values of ultrasound imaging in detecting pericardial effusion/hematoma were analyzed. Clinical appearance of tamponade, need for re-intervention as well as patient outcome were monitored.ResultsIn 12 cases (44%) tamponade necessitated surgical re-intervention. Most common symptoms were deterioration of hemodynamic status and dyspnea. Sensitivity, specificity, positive and negative predictive values of echocardiography were 75%, 64%, 75%, and 64% for detecting pericardial effusion, and 33%, 83%, 50, and 71% for pericardial hematoma, respectively. In-hospital mortality of the re-intervention group was 50%.ConclusionDiagnostic accuracy of transthoracic echocardiography is limited in patients after open heart surgery. Suplemental CT imaging provides rapid diagnostic reliability in patients with delayed cardiac tamponade.
Objective Although a large variety of animal models for acute ischemia and acute heart failure exist, valuable models for studies on the effect of ventricular assist devices in chronic heart failure are scarce. We aimed to establish a stable and reproducible animal model of chronic heart failure in sheep. Methods Sheep (n=8, 77 ± 4 kg) were anesthesized and a 5F sheath was implanted into the left carotid artery. The left main coronary artery was catheterized under flouroscopic guidance and bolus injection of polysterol microspheres (90 μm, n=25.000) was performed. Microembolization (ME) was repeated up to three times in two to three week intervals until animals started to develop stable clinical signs of heart failure. Clinical and echocardiographic data were analyzed at baseline (base) and at three months (3 mo) after first ME. All animals were followed for 3 months after first microembolization and then sacrificed for histological examination. Another four healthy sheep (79±6 kg) served as control animals. Results All animals developed clinical signs of heart failure as indicated by increased heart rate at rest (68±4 bpm (base) to 93 ± 5 bpm (3 mo) (p<0.05)), increased respiratory rate at rest (28±5 (base) to 38 ± 7 (3 mo) (p<0.05)) and increased body weight 77 ± 2 kg to 81 ± 2 kg (p<0.05) due to pleural effusion, peripheral edema and ascites. Echocardiographic evaluation revealed significantly an increase of left ventricular enddiastolic diameter from 46 ± 3 mm (base) to 61 ± 4 mm (3 mo) (p<0.05). Clinically and echocardiographically no significant changes were revealed in healthy control animals. Conclusions We conclude that multiple sequential intracoronary microembolization can effectively induce myocardial dysfunction with clinical and echocardiographical signs of chronic ischemic cardiomyopathy. The present model may be suitable in experimental work on heart failure and left ventricular assist devices, e.g. for studying the impact of mechanical unloading, mechanisms of recovery and reverse remodeling.
Elevated donor TnI serum concentration seems to be a marker for adverse outcome and increased short- and long-term mortality after HTx. Nevertheless, many other perioperative variables and parameters can be associated with outcome.
In conclusion, readmission to the ICU after cardiac surgery is a rare complication that is still associated with excessive mortality. Establishment of an intermediate care unit proved to be an excellent means to reduce ICU stay without endangering post-surgery patients and significantly reduced the ICU readmission rate.
We evaluated the newly developed miniaturized HIA microdiagonal blood pump (MDP) as a continuous flow left ventricular assist device. In a sheep model (n = 6), the MDP was implanted through left lateral thoracotomy and placed paracorporeally with inflow conduit to left atrium and outflow conduit to descending aorta. The sheep were pumped at a mean flow rate of 2.5 L/min for 7 days. Anticoagulation was applied by intravenous heparin administration. Postoperatively, activated clotting time was held stable with values of 200 seconds. During follow-up, blood samples (creatinine kinase, creatinine, glutamic-oxaloacetic transaminase (aspartate aminotransferase) (GOT), glutamate dehydrogenase (GLDH), gamma-GT, plasma-free hemoglobin, and hemoglobine) were taken daily. After 7 days, the sheep were killed for macroscopic examination. Systemic artery pressures remained stable during the whole test period. Because of operative reasons, the hemoglobin value (7.5 +/- 0.61 g/dl) decreased perioperatively, but recovered within the test period, whereas creatinine kinase increased initially after thoracotomy, but decreased to normal within days. Renal and liver functions were slightly impaired perioperatively, indicated by temporarily enhanced values of GOT, gamma-GT, GLDH, and creatinine. The MDP did not produce significant hemolysis as measured by plasma-free hemoglobin levels. Wound infections did not occur. We conclude that the MDP ran successfully as an left ventricular assist device for 7 days in sheep has potential for long-term support, and may serve as an alternative to current technologies. Presented data were not obtained in a clinical trial; however, the results are promising enough to proceed with longer duration animal studies.
BackgroundThe impact of minimized extracorporeal circulation (MECC) for emergency revascularization remains controversial.MethodsA total of 348 patients underwent emergency CABG with MECC (n=146) or conventional extracorporeal circulation (CECC; n=175) between January 2005 and December 2010. Using propensity score matching after binary logistic regression, 100 patients, who underwent CABG with MECC could be matched with 100 patients, who underwent CABG with CECC. Primary outcome was 30-day mortality.ResultsUnadjusted 30-day mortality was 14.8% in patients with CECC and 6.9% in those with MECC (mean difference −7.9%; p=0.03). The adjusted mean difference (average treatment effect of the treated, ATT) after matching was −1.0% (95% CI −8.6 to 7.6; p=1.0). Intensive care unit stay (adjusted mean difference 1.0; 95% CI −0.2 to 3.2; p=0.70) and hospital stay (adjusted mean difference 1.0; 95% CI −2.0 to 3.6; p=0.40) did not show significant differences between both groups. The adjusted mean difference for postoperative low cardiac output syndrome was −1.1% (95% CI −7.3 to 7.1; p=0.83) without significant differences between CECC and MECC. Postoperative mechanical ventilation time, drain loss, postoperative rethoracotomy, postoperative neurological events, new onset renal replacement therapy and respiratory failure also had insignificant average treatment effects of the treated. In addition, all average treatment effects (ATEs) did not significantly differ between both groups.ConclusionUsing propensity score estimation and matching, we did not observe significant differences in terms of survival and further outcomes in patients who undergo emergency CABG with CECC or MECC, but our results call for further analysis.
BackgroundObjective of this study was to evaluate the impact of age on comparative early outcomes after coronary artery bypass graft surgery (CABG) with minimized (MECC) and conventional extracorporeal circulation (CECC).MethodsA retrospective age-, gender- and operation-matched cohort analysis between January 2005 and December 2010 with a total of 2274 patients undergoing CABG with MECC (n = 1137; 50%) or CECC was performed. Patients were stratified into 4 groups according to age: <59 years, 60–69 years, 70–79 years, and 80 years of age or older. Outcomes were compared within each age group. Patients with preoperative dialysis were excluded from analysis. Primary endpoint was 30-day mortality.ResultsPatients treated with CECC had a significantly higher mean logistic EuroSCORE (6.3% vs. 5.0%; p < 0.001), a slightly lower rate of preoperative myocardial infarction (46% vs. 51%; p = 0.01) and a higher rate of impaired renal function (eGFR < 60 mL/min/1.73 m2: 24% vs. 20%; p = 0.01) compared to MECC-patients. Left internal mammary artery was significantly used more often in MECC patients (93% vs. 86%; p < 0.001). Cardiopulmonary bypass and aortic-cross clamping time were significantly lower in the MECC group (p < 0.001). Overall 30-day mortality was significantly higher in patients treated with CECC (4.4% vs. 2.2%; p = 0.002). Within the different age groups mortality rates were not significantly different except for patients aged 60–69 years (4.5% vs. 1.8%; p = 0.03). Postoperative requirement of renal replacement therapy (4% vs. 2.2%; p = 0.01), respiratory insufficiency (9.9% vs. 6.6%; P = 0.004) and incidence of low cardiac output syndrome (3% vs. 1.2%; p = 0.003) were significantly increased in patients with CECC. Multivariate analysis identified age (p = 0.005; 95% CI 1.01 to 1.08; OR 1.05) among other parameters as an independent risk factor, whereas conventional extracorporeal circulation itself did not present as an independent risk factor for 30-day mortality.ConclusionsIn this matched study sample early outcome was significantly better in patients with MECC compared to CECC, irrespective of age. Prior myocardial infarction estimated GFR < 60 mL and waiving the use of LIMA were independent risk factors for 30-day mortality, which were more present in the CECC group.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.