2008
DOI: 10.1097/mat.0b013e318175258e
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturized HIA Microdiagonal Pump as Left Ventricular Assist Device in a Sheep Model

Abstract: We evaluated the newly developed miniaturized HIA microdiagonal blood pump (MDP) as a continuous flow left ventricular assist device. In a sheep model (n = 6), the MDP was implanted through left lateral thoracotomy and placed paracorporeally with inflow conduit to left atrium and outflow conduit to descending aorta. The sheep were pumped at a mean flow rate of 2.5 L/min for 7 days. Anticoagulation was applied by intravenous heparin administration. Postoperatively, activated clotting time was held stable with v… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
11
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
2

Relationship

4
3

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 12 publications
0
11
0
Order By: Relevance
“…Underlining this, Kohlhardt et al described already in the 1960s a significant, moderateacidosisinduced cardiac output decrease in nonfailing cats by 25% (pH = 7.00) (13). Further investigations on acidosis-induced decrease of myocardial contractility and its effect on catecholamine response were performed using different approaches and models (14)(15)(16)(17)(18)(19)(20)(21)(22); however, there still exist no experimental data describing the specific effect of metabolic acidosis in isolated ovine hearts even though sheep are widely used as animal models (23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41).…”
mentioning
confidence: 99%
“…Underlining this, Kohlhardt et al described already in the 1960s a significant, moderateacidosisinduced cardiac output decrease in nonfailing cats by 25% (pH = 7.00) (13). Further investigations on acidosis-induced decrease of myocardial contractility and its effect on catecholamine response were performed using different approaches and models (14)(15)(16)(17)(18)(19)(20)(21)(22); however, there still exist no experimental data describing the specific effect of metabolic acidosis in isolated ovine hearts even though sheep are widely used as animal models (23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41).…”
mentioning
confidence: 99%
“…18,22,29 However, patient mobility is limited, and risks of infection and other adverse events that compromise outcome are quite high. 10 For this reason, long-term options that allow for patient mobility with lower risks of adverse events are being sought.…”
Section: Discussionmentioning
confidence: 99%
“…28,29 The inflow cannula is designed for insertion into the atrium or, with an extended titanium cage into the ventricle. In either case, the tip can be used in the respective chambers on the right or left sides without modifications.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Conventional LVAD procedures have been associated with major incisions, high complication rates, and poor outcomes, but the advent of minimally invasive techniques is changing the entire field . With the fast development and miniaturization of next‐generation devices, outcomes have improved significantly . Minimally invasive procedures mean smaller incisions, less blood loss, shorter hospital stays, and lower costs .…”
Section: Discussionmentioning
confidence: 99%