The dimeric FXIII-A 2 , a pro-transglutaminase is the catalytic part of the heterotetrameric coagulation FXIII-A 2 B 2 complex that upon activation by calcium binding/thrombin cleavage covalently cross-links preformed fibrin clots protecting them from premature fibrinolysis. Our study characterizes the recently disclosed three calcium binding sites of FXIII-A concerning evolution, mutual crosstalk, thermodynamic activation profile, substrate binding, and interaction with other similarly charged ions. We demonstrate unique structural aspects within FXIII-A calcium binding sites that give rise to functional differences making FXIII unique from other transglutaminases. The first calcium binding site showed an antagonistic relationship towards the other two. The thermodynamic profile of calcium/thrombin-induced FXIII-A activation explains the role of bulk solvent in transitioning its zymogenic dimeric form to an activated monomeric form. We also explain the indirect effect of solvent ion concentration on FXIII-A activation. Our study suggests FXIII-A calcium binding sites could be putative pharmacologically targetable regions.
The study evaluated the quality of plasma obtained after whole-blood filtration with four different polyester filters and one polyurethane filter. The activities of coagulation factors and proteinase inhibitors were not or only negligibly affected by filtration, in all experiments. Filtration did not increase markers of clotting and fibrinolysis. Only a strong neutrophil and complement activation was observed, which depended on the type of filter and whole-blood storage conditions. However, as neutrophil elastase-specific degradation products did not increase and the complement-derived anaphylatoxin C3a was found in its inactivated form, C3a-desArg, these filtration-dependent changes apparently have little impact on the therapeutic quality of whole-blood-filtered fresh frozen plasma for transfusion.
Precautionary measures significantly reduced bacterial contamination rates of blood components. Long-term monitoring with standardized methods is appropriate to evaluate the cumulative effect of contamination-preventing measures.
Introduction Standard treatment of congenital haemophilia A is based on replacement therapy with coagulation factor VIII (FVIII) products. A major complication of FVIII therapy is the occurrence of IgG alloantibodies (inhibitors) that neutralize FVIII activity. Aim The aim of the analysis was estimating the risk of high‐titre inhibitor associated with the second‐generation full‐length product compared to third‐generation full‐length product and other recombinant FVIII (rFVIII). Methods We conducted a combined analysis of individual patient data from three large studies in previously untreated patients (PUPs) with severe haemophilia A. Results A total of 1109 PUPs were treated from 1993 to 2013 including 787 PUPs treated from 2004 onwards (primary analysis cohort). A total of 322 patients (29.0%) developed an inhibitor, of which 192 (17.3%) a high‐titre inhibitor. In the primary analysis set, 29.9% of patients developed an inhibitor and 17.2% a high‐titre inhibitor. The combined analysis indicated a lower risk of high‐titre inhibitor development for the third‐generation rFVIII product compared to the second‐generation rFVIII product (primary analysis: adjusted hazard ratio (HR) = 0.72, 95% CI: 0.49 to 1.06). Adjusted HR for all inhibitor development was significantly lower for the third‐generation product compared to the second‐generation product. Conclusion The trend of an increased risk of inhibitor development in PUPs for one recombinant product illustrates that extrapolation from one recombinant factor VIII product to other products might not be justified.
PurposeA prospective, epidemiologic study was conducted to assess whether the 2009 pandemic influenza A(H1N1) vaccination in Germany almost exclusively using an AS03-adjuvanted vaccine (Pandemrix) impacts the risk of Guillain–Barré syndrome (GBS) and its variant Fisher syndrome (FS).MethodsPotential cases of GBS/FS were reported by 351 participating hospitals throughout Germany. The self-controlled case series methodology was applied to all GBS/FS cases fulfilling the Brighton Collaboration (BC) case definition (levels 1–3 of diagnostic certainty) with symptom onset between 1 November 2009 and 30 September 2010 reported until end of December 2010.ResultsOut of 676 GBS/FS reports, in 30 cases, GBS/FS (BC levels 1–3) occurred within 150 days following influenza A(H1N1) vaccination. The relative incidence of GBS/FS within the primary risk period (days 5–42 post-vaccination) compared with the control period (days 43–150 post-vaccination) was 4.65 (95%CI [2.17, 9.98]). Similar results were found when stratifying for infections within 3 weeks prior to onset of GBS/FS and when excluding cases with additional seasonal influenza vaccination. The overall result of temporally adjusted analyses supported the primary finding of an increased relative incidence of GBS/FS following influenza A(H1N1) vaccination.ConclusionsThe results indicate an increased risk of GBS/FS in temporal association with pandemic influenza A(H1N1) vaccination in Germany. © 2014 The Authors. Pharmacoepidemiology and Drug Safety published by John Wiley & Sons, Ltd.
Background: To assess the impact of safety measures, we compared reporting rates of transfusion-related reactions before and after the implementation of six measures in 1999, 2004, 2006, 2008 and 2009. Methods: Reporting rates of transfusion-transmitted bacterial infection (TTBI), viral infection (TTVI) and immune-mediated transfusion-related acute lung injury (TRALI) were calculated on the basis of confirmed annual reports and distributed blood components. Results: The introduction of HCV NAT testing caused a significant reduction of HCV reporting rate from 1:0.6 to 1:83.16 million administered blood components (p < 0.0001), donor screening for antibodies to hepatitis B core antigen caused a reduction of HBV reporting rate from 1:2.90 to 1:10.70 million units (p = 0.0168). A significant reduction from 1:0.094 to 1:2.42 million fresh frozen plasma (FFP) units could also be achieved by risk minimisation TRALI measures (p < 0.0001). Implementation of pre-donation sampling did not result in a significant decrease in TTBI, whereas limitation of shelf life for platelet concentrate (PC) minimised the TTBI reporting rate from 1:0.088 to 1:0.19 million PC units (p = 0.041). For HIV NAT pool testing, no significant reduction in HIV transmission was found due to very low reporting rates (1:10 million versus 1:27 million blood components, p = 0.422). Conclusion: On the basis of haemovigilance data, a significant benefit could be demonstrated for four of six implemented safety measures.
Background: Umbilical cord blood (CB) is widely used for hematopoietic stem cell transplantation and holds promise for the development of innovative medicinal products. In order to find out whether the conditions for collection and storage before processing might have an impact on the quality of CB preparations, viability and the clonogenic potential were assessed. Methods: CB was collected under field conditions. Flow cytometry was used to determine leukocytes, CD34/CD45+ cells, viability, and nucleated red blood cells (NRBC). Clonogenic activity was determined using isolated mononuclear cells (MNC). Results: Neither plasma citrate concentrations nor storage temperature (within 24 h) affected cell viability or colony formation. After storage for 49–80 h, leukocyte viability declined by about 16% compared to CB stored up to 24 h. In contrast, the clonogenic activity and CD34/CD45+ cell content were not affected. A higher gestational age was associated with a lower yield of clonogenic activity compared to midterm deliveries. NRBC varied widely (median 7.3%; range 0.63–17.3%) without relation to gestational age or colony formation. There was a close correlation between the percentage of viable CD34/CD45+ cells and colony formation (r = 0.77 for CFU-GM; r = 0.75 for CFU-C). Conclusions: The content of viable CD34/CD45+ cells represents the clonogenic activity of CB preparations. Therefore, determination of viable CD34/CD45+ cells should be generally performed as a routine quality control assay.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.