Human airways produce nitric oxide (NO), and exhaled NO increases as expiratory flow rates fall. We show that mixing during exhalation between the NO produced by the lower, alveolar airways (VL(NO)) and the upper conducting airways (VU(NO)) explains this phenomenon and permits measurement of VL(NO), VU(NO), and the NO diffusing capacity of the conducting airways (DU(NO)). After breath holding for 10-15 s the partial pressure of alveolar NO (PA) becomes constant, and during a subsequent exhalation at a constant expiratory flow rate the alveoli will deliver a stable amount of NO to the conducting airways. The conducting airways secrete NO into the lumen (VU(NO)), which mixes with PA during exhalation, resulting in the observed expiratory concentration of NO (PE). At fast exhalations, PA makes a large contribution to PE, and, at slow exhalations, NO from the conducting airways predominates. Simple equations describing this mixing, combined with measurements of PE at several different expiratory flow rates, permit calculation of PA, VU(NO), and DU(NO). VL(NO) is the product of PA and the alveolar airway diffusion capacity for NO. In seven normal subjects, PA = 1.6 +/- 0.7 x 10(-6) (SD) Torr, VL(NO) = 0.19 +/- 0.07 microl/min, VU(NO) = 0.08 +/- 0.05 microl/min, and DU(NO) = 0.4 +/- 0.4 ml. min(-1). Torr(-1). These quantitative measurements of VL(NO) and VU(NO) are suitable for exploring alterations in NO production at these sites by diseases and physiological stresses.
Measurements of nitric oxide (NO) pulmonary diffusing capacity (DL(NO)) multiplied by alveolar NO partial pressure (PA(NO)) provide values for alveolar NO production (VA(NO)). We evaluated applying a rapidly responding chemiluminescent NO analyzer to measure DL(NO) during a single, constant exhalation (Dex(NO)) or by rebreathing (Drb(NO)). With the use of an initial inspiration of 5-10 parts/million of NO with a correction for the measured NO back pressure, Dex(NO) in nine healthy subjects equaled 125 +/- 29 (SD) ml x min(-1) x mmHg(-1) and Drb(NO) equaled 122 +/- 26 ml x min(-1) x mmHg(-1). These values were 4.7 +/- 0.6 and 4.6 +/- 0.6 times greater, respectively, than the subject's single-breath carbon monoxide diffusing capacity (Dsb(CO)). Coefficients of variation were similar to previously reported breath-holding, single-breath measurements of Dsb(CO). PA(NO) measured in seven of the subjects equaled 1.8 +/- 0.7 mmHg x 10(-6) and resulted in VA(NO) of 0.21 +/- 0.06 microl/min using Dex(NO) and 0.20 +/- 0.6 microl/min with Drb(NO). Dex(NO) remained constant at end-expiratory oxygen tensions varied from 42 to 682 Torr. Decreases in lung volume resulted in falls of Dex(NO) and Drb(NO) similar to the reported effect of volume changes on Dsb(CO). These data show that rapidly responding chemiluminescent NO analyzers provide reproducible measurements of DL(NO) using single exhalations or rebreathing suitable for measuring VA(NO).
This report describes methods for measuring nitric oxide production by the lungs' lower alveolar airways (VNO), defined as those alveoli and bronchioles well perfused by the pulmonary circulation. Breath holding or vigorous rebreathing for 15-20 s minimizes removal of NO from the lower airways and results in a constant partial pressure of NO in the lower airways (PL). Then the amount of NO diffusing into the perfusing blood will be the pulmonary diffusing capacity for NO (DNO) multiplied by PL and by mass balance equals VNO, or VNO = DNO(PL). To measure PL, 10 normal subjects breath held for 20 s followed by exhalation at a constant flow rate of 0.83 +/- 0.14 (SD) l/s or rebreathed at 59 +/- 15 l/min for 20 s while NO was continuously measured at the mouth. DNO was estimated to equal five times the single-breath carbon monoxide diffusing capacity. By using breath holding, PL equaled 2.9 +/- 0.8 mmHg x 10(-6) and VNO equaled 0.39 +/- 0.12 microl/min. During rebreathing PL equaled 2.3 +/- 0.6 mmHg x 10(-6) and VNO equaled 0.29 +/- 0.11 microl/min. Measurements of NO at the mouth during rapid, constant exhalation after breath holding for 20 s or during rebreathing provide reproducible methods for measuring VNO in humans.
Air exhaled by cigarette smokers contains reduced amounts of nitric oxide (NO). Measurement of NO at different expiratory flow rates permits calculation of NO production by the conducting airways (Vaw(NO)) and alveolar concentration of NO (P(ALV)). An independent measurement of diffusing capacity of the alveolar compartment (D(LNO)) multiplied by P(ALV) allows calculation of NO production by the alveoli (V(LNO)). Twelve asymptomatic cigarette smokers and 22 age-matched nonsmokers had measurements of D(LNO) and expired NO at constant expiratory flow rates varying from 60 to 1500 ml/s. Vaw(NO) in smokers was only 22 +/- 11 nl/min (mean +/- standard deviation, SD) compared to 70 +/- 37 nl/min in nonsmokers (p < .0001). In contrast, V(LNO) showed no significant difference (smokers: 203 +/- 104 nl/min, nonsmokers: 209 +/- 74 nl/min, p = .86). These data show that the diminished NO expired by smokers results from diminished NO production by the tissues of the conducting airways but normal values produced by the alveoli.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.