For biomagnetical applications exploiting physical properties of magnetic nanoparticles (MNP), e.g., magnetic hyperthermia, knowledge about the quantitative spatial MNP distribution is crucial, which can be extracted by magnetorelaxometry (MRX) imaging. In this paper, we present quantification, quantitative 1D reconstruction, and quantitative 2D imaging of MNP by exploiting optically pumped magnetometers for MRX. While highlighting the potential of commercially available optically pumped magnetometers (OPM) for MRXI, we discuss current limitations of the used OPM. We show, that with our OPM setup, MNP can be precisely quantified with iron amounts down to ≈6 μg, which can be improved easily. With a 1D-reconstruction setup, point-like and complex MNP phantoms can be reconstructed quantitatively with high precision and accuracy. We show that with our developed 2D MRX imaging setup, which measures 12 cm by 8 cm, point-like MNP distributions with clinically relevant iron concentrations can be reconstructed precisely and accurately. Our 2D setup has the potential to be easily extended to a tomography styled (and thus slice-selective) 3D scanner, by adding a mechanical axis to the phantom.
Magnetorelaxometry imaging is a highly sensitive technique enabling noninvasive, quantitative detection of magnetic nanoparticles. Electromagnetic coils are sequentially energized, aligning the nanoparticles' magnetic moments. Relaxation signals are recorded after turning off the coils. The forward model describing this measurement process is reformulated into a severely ill-posed inverse problem that is solved for estimating the particle distribution. Typically, many activation sequences employing different magnetic fields are required to obtain reasonable imaging quality. We seek to improve the imaging quality and accelerate the imaging process using fewer activation sequences by optimizing the applied magnetic fields. Minimizing the Frobenius condition number of the system matrix, we stabilize the inverse problem solution toward model uncertainties and measurement noise. Furthermore, our sensitivity-weighted reconstruction algorithms improve imaging quality in lowly sensitive areas. The optimization approach is employed to real measurement data and yields improved reconstructions with fewer activation sequences compared to non-optimized measurements.
Stable posture and body movement in humans is dictated by the precise functioning of the ampulla organs in the semi-circular canals. Statistical analysis of the interrelationship between bony and membranous compartments within the semi-circular canals is dependent on the visualization of soft tissue structures. Thirty-one human inner ears were prepared, post-fixed with osmium tetroxide and decalcified for soft tissue contrast enhancement. High resolution X-ray microtomography images at 15 μm voxel-size were manually segmented. This data served as templates for centerline generation and cross-sectional area extraction. Our estimates demonstrate the variability of individual specimens from averaged centerlines of both bony and membranous labyrinth. Centerline lengths and cross-sectional areas along these lines were identified from segmented data. Using centerlines weighted by the inverse squares of the cross-sectional areas, plane angles could be quantified. The fit planes indicate that the bony labyrinth resembles a Cartesian coordinate system more closely than the membranous labyrinth. A widening in the membranous labyrinth of the lateral semi-circular canal was observed in some of the specimens. Likewise, the cross-sectional areas in the perilymphatic spaces of the lateral canal differed from the other canals. For the first time we could precisely describe the geometry of the human membranous labyrinth based on a large sample size. Awareness of the variations in the canal geometry of the membranous and bony labyrinth would be a helpful reference in designing electrodes for future vestibular prosthesis and simulating fluid dynamics more precisely.
Our sense of balance and spatial orientation strongly depends on the correct functionality of our vestibular system. Vestibular dysfunction can lead to blurred vision and impaired balance and spatial orientation, causing a significant decrease in quality of life. Recent studies have shown that vestibular implants offer a possible treatment for patients with vestibular dysfunction. The close proximity of the vestibular nerve bundles, the facial nerve and the cochlear nerve poses a major challenge to targeted stimulation of the vestibular system. Modeling the electrical stimulation of the vestibular system allows for an efficient analysis of stimulation scenarios previous to time and cost intensive in vivo experiments. Current models are based on animal data or CAD models of human anatomy. In this work, a (semi-)automatic modular workflow is presented for the stepwise transformation of segmented vestibular anatomy data of human vestibular specimens to an electrical model and subsequently analyzed. The steps of this workflow include (i) the transformation of labeled datasets to a tetrahedra mesh, (ii) nerve fiber anisotropy and fiber computation as a basis for neuron models, (iii) inclusion of arbitrary electrode designs, (iv) simulation of quasistationary potential distributions, and (v) analysis of stimulus waveforms on the stimulation outcome. Results obtained by the workflow based on human datasets and the average shape of a statistical model revealed a high qualitative agreement and a quantitatively comparable range compared to data from literature, respectively. Based on our workflow, a detailed analysis of intra- and extra-labyrinthine electrode configurations with various stimulation waveforms and electrode designs can be performed on patient specific anatomy, making this framework a valuable tool for current optimization questions concerning vestibular implants in humans.
Objective. Magnetorelaxometry imaging (MRXI) is an experimental imaging technique applicable for noninvasive, qualitative and quantitative imaging of magnetic nanoparticles (MNPs). Accurate reconstructions of nanoparticle distributions are crucial for several novel treatment methods employing MNPs such as magnetic drug targeting or magnetic hyperthermia therapy. Hence, it is desirable to design MRXI setups such that the reconstruction accuracy is maximized for a given set of design parameters. Several attempts exist in literature that focus on the improvement of MRXI and other related linear inverse problems with respect to various figures of merit. However, to date it remains unclear, which approach leads to the largest benefit for the reconstruction accuracy. Thus, the aim of this study is to compare the different figures of merit, thereby determining the most reliable and effective optimization approach for magnetorelaxometry setups. Approach. In the present simulation study, we translate these figures of merit to various cost functions, allowing us to optimize the electromagnetic coil positions and radii of two distinct MRXI setups with an adapted tabu search algorithm. Multiple artificial MNP phantoms are reconstructed employing the optimized setups and the resulting imaging qualities are subsequently compared. Main results. The extensive amount of generated synthetic data unprecedented in previous MRXI studies identifies the condition number as the most reliable indicator for good imaging results. This is the case for both the qualitative as well as the quantitative reconstruction accuracies. Significance. The results of this study show that optimized coil configurations increase the reconstruction quality compared to the state-of-the-art. The insights obtained here can also be extended to other design parameters of MRXI setups, thus enabling more reliable reconstructions of MNP ensembles which will ultimately render the aforementioned treatment methods safer and more efficient.
Magnetic nanoparticles have many applications in biomedicine and other technical areas. Despite their huge economic impact, there are no standardised procedures available to measure their basic magnetic properties. The International Organization for Standardization is working on a series of documents on the definition of characteristics of magnetic nanomaterials. We review previous and ongoing European research projects on characteristics of magnetic nanoparticles and present results of an online survey among European researchers.
A dysfunctional vestibular system can be a severe detriment to the quality of life of a patient. Recent studies have shown the feasibility for a vestibular implant to restore rotational sensation via electrical stimulation of vestibular ampullary nerves. However, the optimal stimulation site for selective elicitation of the desired nerve is still unknown. We realized a finite element model on the basis of μCT scans of a human inner ear and incorporated naturally distributed, artificial neural trajectories. A well-validated neuron model of myelinated fibers was incorporated to predict nerve responses to electrical stimulation. Several virtual electrodes were placed in locations of interest inside the bony labyrinth (intra-labyrinthine) and inside the temporal bone, near the target nerves (extra-labyrinthine), to determine preferred stimulation sites and electrode insertion depths. We investigated various monopolar and bipolar electrode configurations as well as different pulse waveform shapes for their ability to selectively stimulate the target nerve and for their energy consumption. The selectivity was evaluated with an objective measure of the fiber recruitment. Considerable differences of required energy and achievable selectivity between the configurations were observed. Bipolar, intra-labyrinthine electrodes provided the best selectivities but also consumed the highest amount of energy. Bipolar, extra-labyrinthine configurations did not offer any advantages compared to the monopolar approach. No selective stimulation could be performed with the monopolar, intra-labyrinthine approach. The monopolar, extra-labyrinthine electrodes required the least energy for satisfactory selectivities, making it the most promising approach for functional vestibular implants. Different pulse waveform shapes did not affect the achieved selectivity considerably but shorter pulse durations showed consistently a more selective activation of the target nerves. A cathodic, centered triangular waveform shape was identified as the most energy-efficient of the tested shapes. Based on these simulations we are able to recommend the monopolar, extra-labyrinthine stimulation approach with cathodic, centered triangular pulses as good trade-off between selectivity and energy consumption. Future implant designs could benefit from the findings presented here.
Recent studies show that vestibular implants have the potential to compensate the loss of functionality of the organ of equilibrium. The objective of this study was the development of a simulation framework which estimates the capability of various electrode arrangements and stimulation waveforms to selectively excite the ampullary nerves in the vestibular system. The choice of electrode configuration and stimulation waveform shows a significant influence in resulting selectivity, energy expenditure and injected charge in our simulations. This simulation environment could be beneficial in the development of safe and selective stimulation electrode designs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.