Background and purpose — Trochanteric fractures are often treated using intramedullary fixation. In our institution, the TFN-Advanced Proximal Femoral Nailing System (TFNA) was introduced as replacement for the Gamma Trochanteric Nail (GTN3) for the treatment of these fractures as a result of a hospital-driven change of trauma implant supplier. We compared trochanteric fracture fixation failure rate between these 2 intramedullary nails.
Patients and methods — All trochanteric fractures treated surgically from 2011 to 2019 were retrospectively reviewed for fixation failure. From 2016 only the TFNA was used. Fixation failure was defined as implant cut-out, implant breakage, non-union, malpositioning of the screw/blade requiring reoperation, new fracture around the nail, or miscellaneous. Propensity score matching was used to balance distribution of covariates and to compare failure rates between TFNA and GTN3 groups. Learning curve analyseswere performed.
Results — After exclusion, 797 GTN3s (779 patients) and 542 (536 patients) TFNAs were available for analysis. A higher risk of fixation failure was found in the TFNA group (14%) compared with the GTN3 group (7.0%) (hazard ratio [HR] 2.0, 95% confidence interval [CI] 1.2–3.5). This was mainly attributed to a higher risk of cut-out (HR 2.2; CI 0.9–5.7), malpositioning (HR 4.7; CI 0.7–34), and new fracturearound the nail (HR 4.0; CI 1.0–16). Learning curve analyses indicated no clear learning curve effect.
Interpretation — Failure of fixation increased after a switch from the GTN3 to the TFNA proximal femoral nail for the treatment of trochanteric fractures. Cut-out and malpositioning of the calcar screw or blade appeared to be the most dominant failure mechanisms. Modifications in implant design may have played a role in this increased risk of failure of fixation. In our institution a new implant device was introduced without solid clinical evidence behind it. This study may help to underline the need for medical doctors with acritical and scientific background to be involved in implant choices.
Patient satisfaction after THA remains high after prolonged follow-up. Apparently patients do not get used to the successful results of their THA. A rather low correlation with common clinical outcome parameters suggests that patient satisfaction is a separate entity. Since patient satisfaction correlated best with pain during activity, this is probably the most important aspect in patient satisfaction. Measurement of patient satisfaction has additional value and may even replace some of the more commonly used questionnaires.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.