Osteochondral transplantation is a successful treatment for full-thickness cartilage defects, which without treatment would lead to early osteoarthritis. Restoration of surface congruency and stability of the reconstruction may be jeopardized by early mobilization. To investigate the biomechanical effectiveness of osteochondral transplantation, we performed a standardized osteochondral transplantation in eight intact human cadaver knees, using three cylindrical plugs on a fullthickness cartilage defect, bottomed on one condyle, unbottomed on the contralateral condyle. Surface pressure measurements with Tekscan pressure transducers were performed after five conditions. In the presence of a defect the border contact pressure of the articular cartilage defect significantly increased to 192% as compared to the initially intact joint surface. This was partially restored with osteochondral transplantation (mosaicplasty), as the rim stress subsequently decreased to 135% of the preoperative value. Following weight bearing motion two out of eight unbottomed mosaicplasties showed subsidence of the plugs according to Tekscan measurements. This study demonstrates that a three-plug mosaicplasty is effective in restoring the increased border contact pressure of a cartilage defect, which may postpone the development of early osteoarthritis. Unbottomed mosaicplasties may be more susceptible for subsidence below flush level after (unintended) weight bearing motion.
Background Osteochondral autologous transplantation is used for the treatment of full-thickness articular cartilage lesions of a joint. Press-fit stability is an important factor for good survival of the transplanted plugs.Material and methods 36 plugs of three different lengths were transplanted in fresh-frozen human knees. On one condyle, 3 plugs were exactly matched to the depth of the recipient site ("bottomed" plugs) and on the opposite condyle 3 plugs were 5 mm shorter than the depth of the recipient site ("unbottomed" plugs). Plugs were left protruding and then pushed in until flush, and then to 2 mm below flush level, using a loading apparatus.Results Longer plugs needed higher forces to begin displacement. At flush level, bottomed plugs needed significantly higher forces than unbottomed plugs to become displaced below flush level (mean forces of 404 N and 131 N, respectively). Shorter bottomed plugs required higher forces than longer bottomed ones.Interpretation Bottomed plugs generally provide much more stability than unbottomed ones. Short bottomed plugs are more stable than long bottomed plugs. Thus, in clinical practice it is advisable to use short bottomed plugs. If, however, unbottomed plugs are still chosen, the longer the plug the higher the resulting stability will be because of higher frictional forces.
Metal ions generated from joint replacements are a cause for concern. There is no consensus on the best surrogate measure of metal ion exposure, and both serum and whole blood measurements are used in clinical practice. This study provides a guideline for interpretation of metal ion analysis in clinical practice. In a prospective trial comparing hip resurfacing (HR) with a conventional metal-on-metal (MoM) total hip arthroplasty (THA) cobalt and chromium levels were determined for whole blood and serum in 343 paired samples at regular intervals up to 24 months postoperatively. Cobalt whole blood and serum levels increased significantly after both procedures. Cobalt concentrations were significantly higher for the HR group compared to the THA group, at 3, 6 and 12 months, for whole blood and serum. At 24 months cobalt levels decreased and differences between HR and THA were no longer significant. In contrast, chromium whole blood levels remained significantly higher for HR until 24 months. Whole blood and serum levels could not be used interchangeably. The mean differences for cobalt and chromium between blood and serum values were +0.13 µg/L and -0.91 µg/L respectively. Regression analysis provided a formula for conversion from serum to blood of 0.34+[0.88*Co serum] for cobalt and 0.14 + [0.58*Cr serum] for chromium, with an acceptable prediction error below ±1.0 µg/L. Cobalt and chromium levels were significantly higher for HR versus THA, especially during the run-in phase of one year. Overall, the metal ion levels were well below 5 µg/L. We cannot recommend the use of whole blood over serum measurements or vice versa. The provided conversion formula between whole blood and serum in combination with the presented practical guidelines may be useful for clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.