The development of tissue-engineered blood vessels provides a new source of donors for coronary artery bypass grafting and peripheral blood vessel transplantation. Fibrin fiber has good biocompatibility and is an ideal tissue engineering vascular scaffold, but its mechanical property needs improvement. Methods: We mixed polyurethane (PU) and fibrin to prepare the PU/fibrin vascular scaffolds by using electrospinning technology in order to enhance the mechanical properties of fibrin scaffold. We investigated the morphological, mechanical strength, hydrophilicity, degradation, blood and cell compatibility of PU/fibrin (0:100), PU/fibrin (5:95), PU/fibrin (15:85) and PU/fibrin (25:75) vascular scaffolds. Based on the results in vitro, PU/fibrin (15:85) was selected for transplantation in vivo to repair vascular defects, and the extracellular matrix formation, vascular remodeling, and immune response were evaluated. Results: The results indicated that the fiber diameter of the PU/fibrin (15:85) scaffold was about 712nm. With the increase of PU content, the mechanical strength of the composite scaffolds increased, however, the degradation rate decreased gradually. The PU/fibrin scaffold showed good hydrophilicity and hemocompatibility. PU/fibrin (15:85) vascular scaffold could promote the adhesion and proliferation of mesenchymal stromal cells (MSCs). Quantitative RT-PCR experimental results showed that the expression of collagen, survivin and vimentin genes in PU/fibrin (15:85) was higher than that in PU/fibrin (25:75). The results in vivo indicated the mechanical properties and compliance of PU/fibrin grafts could meet clinical requirements and the proportion of thrombosis or occlusion was significantly lower. The graft showed strong vasomotor response, and the smooth muscle cells, endothelial cells, and ECM deposition of the neoartery were comparable to that of native artery after 3 months. At 3 months, the amount of macrophages in PU/fibrin grafts was significantly lower, and the secretion of pro-inflammatory and anti-inflammatory cytokines decreased. Conclusion: PU/fibrin (15:85) vascular scaffolds had great potential to be used as smalldiameter tissue engineering blood vessels.
Tissue engineering is an alternative method for preparing small-caliber (<6 mm) vascular grafts. Dynamic mechanical conditioning is being researched as a method to improve mechanical properties of tissue engineered blood vessels. This method attempts to induce unique reaction in implanted cells that regenerate the matrix around them, thereby improving the overall mechanical stability of the grafts. In this
Background and aims: Genipin, an iridoid derived from geniposide by β-glucosidase hydrolysis, has shown potential benefit in the treatment of heart function insufficiency despite its unclear therapeutic mechanism. This study aimed to investigate the primary cardioprotective mechanism of genipin. We hypothesized that genipin demonstrated the antiapoptosis and anti-inflammation for cardiac protection by inhibiting the cyclooxidase 2 (COX2)–prostaglandin D2 (PGD2) and murine double minute 2 (MDM2)–p53 pathways. Methods: The normal Sprague-Dawley rats were made into myocardial infarction models by conventional methods. Animals were treated with genipin for 5 weeks after myocardial infarction (MI). Morphometric and hemodynamic measurements were performed 5 weeks post-MI. Biological and molecular experiments were performed after the termination. Results: Both morphometry and hemodynamics in systole and diastole were significantly impaired in the model group but restored close to basal level after treatment with genipin. Genipin also restored the post-MI upregulated expressions of cytochrome c, p53, COX2, and PGD2 and downregulated expression of MDM2 to the approximate baseline. Genipin inhibited apoptotic and inflammatory pathways to prevent post-MI structure-function remodeling. Conclusions: This study showed the cardioprotective mechanism of genipin and implied its potential clinical application for the treatment of ischemic heart failure.
The incidence rate of cardiovascular diseases is increasing year by year. The demand for coronary artery bypass grafting has been very large. Acellular blood vessels have potential clinical application because of their natural vascular basis, but their biocompatibility and anticoagulant energy need to be improved. We decellularized the abdominal aorta of SD rats, and then modified with bivalirudin via polydopamine. The mechanical properties, blood compatibility, cytocompatibility, immune response, and anticoagulant properties were evaluated, and then the bivalirudin-modified acellular blood vessels were implanted into rats for remodeling evaluation in vivo. The results we got show that the bivalirudin-modified acellular blood vessels showed good cytocompatibility and blood compatibility, and its anti-inflammatory trend was dominant in the immune response. After 3 months of transplantation, the bivalirudinmodified acellular blood vessels did not easily form thrombus. It was not easy to form calcification and could make the host cells grow better. Through vascular stimulation and immunofluorescence test, we found that vascular smooth muscle cells and endothelial cells proliferated well in the bivalirudin group. Bivalirudin-modified acellular blood vessels provided new idea for small diameter tissue engineering blood vessels, and may become a potential clinical substitute for small-diameter vascular grafts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.