Surgeons starting to perform Descemet membrane endothelial keratoplasty (DMEK) should be informed about the learning curve and experience of others. OBJECTIVE To document the clinical outcome of standardized "no-touch" DMEK and its complications during the learning curves of experienced surgeons. DESIGN, SETTING, AND PARTICIPANTS Retrospective multicenter study. A total of 431 eyes from 401 patients with Fuchs endothelial dystrophy (68.2%) and bullous keratopathy (31.8%) underwent DMEK performed by 18 surgeons in 11 countries. EXPOSURES Descemet membrane endothelial keratoplasty. MAIN OUTCOMES AND MEASURES Best-corrected visual acuity (BCVA), endothelial cell density, and intraoperative and postoperative complications. RESULTS Of 275 eyes available for BCVA pooled analysis, BCVA improved in 258 eyes (93.8%), remained unchanged in 12 (4.4%), and deteriorated in 5 (1.8%). Two hundred seventeen eyes (78.9%) reached a BCVA of at least 20/40 (Ն0.5), 117 (42.5%) at least 20/25 (Ն0.8), and 61 (22.2%) at least 20/20 (Ն1.0). Eyes with at least 6 months of follow-up (n = 176) reached similar BCVA outcomes. Mean (SD) decrease in endothelial cell density at 6 months was 47% (20%) (n = 133 [P = .02]). Intraoperative complications were rare, including difficulties in inserting, unfolding, or positioning of the graft (1.2%) and intraoperative hemorrhage (0.5%). The main postoperative complication was graft detachment (34.6%); 20.4% underwent a single rebubbling procedure, occasionally requiring a second (2.6%) and a third rebubbling (0.7%), and 17.6% underwent a second keratoplasty.CONCLUSIONS AND RELEVANCE Our multicenter study showed that the standardized no-touch DMEK technique was feasible in most hands. The main challenges for surgeons starting to perform the procedure may be (1) to decide whether graft preparation is outsourced or performed during surgery, (2) to limit the number of graft detachments and secondary procedures, and (3) to obtain organ cultured donor corneal tissue.
The application of polymeric biomaterial scaffolds utilizing crosslinking strategy has become an effective approach in these days. In the present study, the development and characterization of collagen–chitosan hydrogel film has been reported on using dual crosslinking agent’s, i.e., tannic acid and genipin simultaneously. Incorporation of genipin imparts a greenish-blue color to the polymeric film. The effect of dual crosslinking and their successful interaction within the matrix was evaluated by infrared analysis spectroscopy. The porosity of the film was examined using scanning electron microscopy (SEM). Results of TGA determine the intermediate thermal degradation. Further, the crosslinking phenomenon has found primary impact on the strength of the films. Enzymatic degradation for the films was performed with lysozyme and lipase. The cell adhesion and proliferation was also accomplished using mouse embryonic cell lines wherein the cells cultured on the dual crosslinked film. The thriving utilization of such dual crosslinked polymeric film finds their applications in ophthalmology especially as an implant for temporary injured cornea and skin tissue regeneration.
Aim To evaluate the potential of the Support Vector Machine Regression model (SVM-RM) and Multilayer Neural Network Ensemble model (MLNN-EM) to improve the intraocular lens (IOL) power calculation for clinical workflow. Background Current IOL power calculation methods are limited in their accuracy with the possibility of decreased accuracy especially in eyes with an unusual ocular dimension. In case of an improperly calculated power of the IOL in cataract or refractive lens replacement surgery there is a risk of re-operation or further refractive correction. This may create potential complications and discomfort for the patient. Methods A dataset containing information about 2,194 eyes was obtained using data mining process from the Electronic Health Record (EHR) system database of the Gemini Eye Clinic. The dataset was optimized and split into the selection set (used in the design for models and training), and the verification set (used in the evaluation). The set of mean prediction errors (PEs) and the distribution of predicted refractive errors were evaluated for both models and clinical results (CR). Results Both models performed significantly better for the majority of the evaluated parameters compared with the CR. There was no significant difference between both evaluated models. In the ±0.50 D PE category both SVM-RM and MLNN-EM were slightly better than the Barrett Universal II formula, which is often presented as the most accurate calculation formula. Conclusion In comparison to the current clinical method, both SVM-RM and MLNN-EM have achieved significantly better results in IOL calculations and therefore have a strong potential to improve clinical cataract refractive outcomes.
Purpose: To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. Methods: 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. Results: The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to −0.15 D at the 4 -6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was −0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of −0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. Conclusion: The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.
Several studies have shown that visual recovery after blindness that occurs early in life is never complete. The current study investigated whether an extremely long period of blindness might also cause a permanent impairment of visual performance, even in a case of adult-onset blindness. We examined KP, a 71-year-old man who underwent a successful sight-restoring operation after 53 years of blindness. A set of psychophysical tests designed to assess KP's face perception, object recognition, and visual space perception abilities were conducted six months and eight months after the surgery. The results demonstrate that regardless of a lengthy period of normal vision and rich pre-accident perceptual experience, KP did not fully integrate this experience, and his visual performance remained greatly compromised. This was particularly evident when the tasks targeted finer levels of perceptual processing. In addition to the decreased robustness of his memory representations, which was hypothesized as the main factor determining visual impairment, other factors that may have affected KP's performance were considered, including compromised visual functions, problems with perceptual organization, deficits in the simultaneous processing of visual information, and reduced cognitive abilities.
Overall, the flap dimensions and refractive results were predictable and the complication rate was acceptable after LASIK using the new femtosecond laser for flap creation.
We report 2 intraocular lenses (IOLs) manufactured from the same hydrophilic acrylic polymer by Ioltech that developed optic opacification. In both cases, the postoperative course after implantation of the IOLs was complicated by significant inflammatory reaction with fibrin formation in the anterior chamber. Pathologic analyses of the explanted IOLs were consistent with dystrophic calcification leading to optic opacification, but the pattern was different between the 2 IOL designs. Patient-related factors might have been responsible for this complication.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.