SUMMARY:The aim of this research was to evaluate the risk factors related to condylar resorption (CR) after orthognathic surgery. Was realized a systematic review with a search of the literature performed in the electronic databases PubMed, MedLine, Ovid, Cochrane Library for current evidence in the world literature as conducted, and relevant articles were selected in according to inclusion and exclusion criteria and the findings were compared. Eight papers, (follow-up 12 months to 69 months) were including. A sample of 2567 patient with mandible or bi maxillary surgery with an age range from 14 to 46 year old was observed. In 137 patients (5.3%) CR was observed , with a 97.6% (122) female. CR was related to 118 cases with mandibular deficiencies with high mandibular plane (advancement surgery). CR were present principally in bi maxillary surgery with a 103 cases (75.2%) and only two papers show any analysis to the relation with TMJ dysfunction. Current evidence in CR is poor but supports those female patients with mandibular deficiency and high mandibular plane angle submitted to bi maxillary surgery with change in occlusal plane (counterclockwise) are associated with condylar resorption after orthognathic surgery.
PurposeSeveral parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues.MethodsTwelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance.ResultsThe present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings.ConclusionsZirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.
SUMMARY: Dental implant and chin osteotomy are executed on the mandible body and the mental nerve is an important anatomical limit. The aim of this research was to know the position of the mental nerve loop comparing result in panoramic radiography and cone beam computed tomography. We analyzed 94 hemimandibles and the patient sample comprised female and male subjects of ages ranging from 18 to 52 years (mean age, 35 years) selected randomly from the database of patients at the Division of Oral Radiology at Piracicaba Dental School State University of Campinas; the anterior loop (AL) of the mental nerve was evaluated regarding the presence or absence, which was classified as rectilinear or curvilinear and measurement of its length was obtained. The observations were made in the digital panoramic radiography (PR) and the cone beam computed tomography (CBCT) according to a routine technique. The frequencies of the AL identified through PR and CBCT were different: in PR the loop was identified in 42.6% of cases, and only 12.8% were bilateral. In contrast, the AL was detected in 29.8% of the samples using CBCT, with 6.4% being bilateral; Statistical comparison between PR and CBCT showed that the PR led to false-positive diagnosis of the AL in this sample. According to the results of this study, the frequency of AL is low. Thus, it can be assumed that it is not a common condition in this population.
Mucoepidermoid carcinoma in paediatric patients is uncommon, but it must be considered in differential diagnoses of intraoral submucosal mass/nodules in children, particularly in the palate.
SUMMARY:The planning and 3D reconstruction in craniofacial defects based on anatomical principles of symmetry and passive adaptation has evolved radically the past few years. This article recounts the possibility to develop personalized and extensive craniofacial implants. We present a case of a patient with a 10-year trauma sequel evolution; the patient lost the right frontal bone, supraorbital wall and part of the temporal fossa. From the computerized tomography, and by using Materialise software (3-Matic and Mimics). Subsequently, the printing was performed using the virtual planning with a laser printer in titanium where the piece was elaborated with the determined specifications in the planning; surgery was performed without complications in which the implant was placed via a coronal approach, which did not require any type of adaptation. After a two-year follow-up we observed a correct position, symmetry, absence of infection or any other alteration. It is concluded that the planning and 3D printing are suitable to perform craniofacial reconstructions with a low morbidity, shorter surgical time, and with an adequate facial symmetry and aesthetic return.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.