Background and Purpose: Remote beam output audits, which independently measure an institution’s machine calibration, are a common component of independent radiotherapy peer review. This work reviews the results and trends of these audit results across several organisations and geographical regions. Materials and Methods: Beam output audit results from the Australian Clinical Dosimetry Services, International Atomic Energy Agency, Imaging and Radiation Oncology Core, and Radiation Dosimetry Services were evaluated from 2010 to the present. The rate of audit results outside a +/−5% tolerance was evaluated for photon and electron beams as a function of the year of irradiation and nominal beam energy. Additionally, examples of confirmed calibration errors were examined to provide guidance to clinical physicists and auditing bodies. Results: Of the 210,167 audit results, 1323 (0.63%) were outside of tolerance. There was a clear trend of improved audit performance for more recent dates, and while all photon energies generally showed uniform rates of results out of tolerance, low (6 MeV) and high (≥18 MeV) energy electron beams showed significantly elevated rates. Twenty nine confirmed calibration errors were explored and attributed to a range of issues, such as equipment failures, errors in setup, and errors in performing the clinical reference calibration. Forty-two percent of these confirmed errors were detected during ongoing periodic monitoring, and not at the time of the first audit of the machine. Conclusions: Remote beam output audits have identified, and continue to identify, numerous and often substantial beam calibration errors.
The International Atomic Energy Agency (IAEA) has established a database describing activities of dosimetry audit networks (DAN) in radiotherapy. Since 2010 the data on different aspects of the dosimetry audit have been collected. This information has allowed for the analysis and comparison of current practices in dosimetry auditing activities worldwide. Overall, 79 organizations in 58 countries confirmed that they offer dosimetry audit services for radiotherapy; however, access of radiotherapy centres to the audit remains insufficient. Increased availability of audits is necessary to improve dosimetry practices, reduce the likelihood of errors and the consequences that would result for patients' health.
Introduction: Within an International Atomic Energy Agency (IAEA) coordinated research project (CRP), a remote end-to-end dosimetric quality audit for intensity modulated radiation therapy (IMRT)/ volumetric arc therapy (VMAT) was developed to verify the radiotherapy chain including imaging, treatment planning and dose delivery. The methodology as well as the results obtained in a multicentre pilot study and national trial runs conducted in close cooperation with dosimetry audit networks (DANs) of IAEA Member States are presented. Material and methods: A solid polystyrene phantom containing a dosimetry insert with an irregular solid water planning target volume (PTV) and organ at risk (OAR) was designed for this audit. The insert can be preloaded with radiochromic film and four thermoluminescent dosimeters (TLDs). For the audit, radiotherapy centres were asked to scan the phantom, contour the structures, create an IMRT/VMAT treatment plan and irradiate the phantom. The dose prescription was to deliver 4 Gy to the PTV in two fractions and to limit the OAR dose to a maximum of 2.8 Gy. The TLD measured doses and film measured dose distributions were compared with the TPS calculations. Results: Sixteen hospitals from 13 countries and 64 hospitals from 6 countries participated in the multicenter pilot study and in the national runs, respectively. The TLD results for the PTV were all within ±5% acceptance limit for the multicentre pilot study, whereas for national runs, 17 participants failed to meet this criterion. All measured doses in the OAR were below the treatment planning constraint. The film analysis identified seven plans in national runs below the 90% passing rate gamma criteria. Conclusion: The results proved that the methodology of the IMRT/VMAT dosimetric end-to-end audit was feasible for its intended purpose, i.e., the phantom design and materials were suitable; the phantom was easy to use and it was robust enough for shipment. Most importantly the audit methodology was capable of identifying suboptimal IMRT/VMAT delivery.
Background: The IAEA/WHO postal dose audit programme has been operating since 1969 with the aim of improving the accuracy and consistency of dosimetry in radiotherapy in low-income and middle-income countries world-wide. This study summarises the 50 years' experience of audits and explores the quality of reference dosimetry in participating radiotherapy centres throughout the years. Material and methods: During the IAEA/WHO postal audits the dose determined from the mailed dosimeter is compared with that stated by the participant. Agreement to within ±5% is regarded acceptable whilst deviations outside ±5% limits trigger follow-up actions. Of particular interest in this study was the dependence of clinical dosimetry quality on factors related to the centre infrastructure and expertise in dosimetry of its staff. Results: The IAEA/WHO dose audit programme noted great increase in the overall percentage of acceptable results from about 50% in its early years to 99% at present, although there is some variability of results amongst participating countries. Whereas results for younger radiotherapy machines show the agreement rate between the measured and the stated doses well above 90%, for those over 20 years old the rate dropped to <80%. Linac dosimetry was always better than 60 Co dosimetry and multi-machine centres generally performed better than single machine centres equipped with cobalt alone. Second and subsequent participation in audits showed higher quality dosimetry than the first participation. The implementation of modern dosimetry protocols resulted in more accurate dosimetry than the use of the older protocols. Conclusions: Over the 50 years that the IAEA has accumulated dosimetry audit data, practices in radiotherapy centres have significantly improved. Higher quality dosimetry confirmed in audits is generally associated with better infrastructure and adequate dosimetry expertise of medical physicists in participating centres.
The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP ‘Development of Quality Audits for Radiotherapy Dosimetry for Complex Treatment Techniques’ was conducted in 2009–2012 as an extension of previously developed audit programs. Material and methods. The CRP work described in this paper focused on developing and testing two steps of dosimetry audit: verification of heterogeneity corrections, and treatment planning system (TPS) modeling of small MLC fields, which are important for the initial stages of complex radiation treatments, such as IMRT. The project involved development of a new solid slab phantom with heterogeneities containing special measurement inserts for thermoluminescent dosimeters (TLD) and radiochromic films. The phantom and the audit methodology has been developed at the IAEA and tested in multi-center studies involving the CRP participants. Results. The results of multi-center testing of methodology for two steps of dosimetry audit show that the design of audit procedures is adequate and the methodology is feasible for meeting the audit objectives. A total of 97% TLD results in heterogeneity situations obtained in the study were within 3% and all results within 5% agreement with the TPS predicted doses. In contrast, only 64% small beam profiles were within 3 mm agreement between the TPS calculated and film measured doses. Film dosimetry results have highlighted some limitations in TPS modeling of small beam profiles in the direction of MLC leave movements. Discussion. Through multi-center testing, any challenges or difficulties in the proposed audit methodology were identified, and the methodology improved. Using the experience of these studies, the participants could incorporate the auditing procedures in their national programs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.