Background: Ultra-high density mapping (HDM) is a promising tool in the treatment of patients with complex arrhythmias. In adults with congenital heart disease (CHD), rhythm disorders are among the most common complications but catheter ablation can be challenging due to heterogenous anatomy and complex arrhythmogenic substrates. Here, we describe our initial experience using HDM in conjunction with novel automated annotation algorithms in patients with moderate to great CHD complexity.Methods: We studied a series of consecutive adult patients with moderate to great CHD complexity and an indication for catheter ablation due to symptomatic arrhythmia. HDM was conducted using the Rhythmia™ mapping system and a 64-electrode mini-basket catheter for identification of anatomy, voltage, activation pattern and critical areas of arrhythmia for ablation guidance. To investigate novel advanced mapping strategies, postprocedural signal processing using the Lumipoint™ software was applied.Results: In 19 patients (53±3 years; 53% male), 21 consecutive ablation procedures were conducted.Procedures included ablation of atrial fibrillation (n=7; 33%), atrial tachycardia (n=11; 52%), atrioventricular accessory pathway (n=1; 5%), the atrioventricular node (n=1; 5%) and ventricular arrhythmias (n=4; 19%). A total of 23 supraventricular and 8 ventricular arrhythmias were studied with the generation of 56 complete high density maps (atrial n=43; ventricular n=11, coronary sinus n=2) and an average of 12,043±1,679 mapping points. Multiple arrhythmias were observed in n=7 procedures (33% of procedures; range of arrhythmias detected 2-4). A total range of 1-4 critical areas were defined per procedure and treated within a radiofrequency application time of 16 (interquartile range 12-45) minutes. Postprocedural signal processing using Lumipoint™ allowed rapid annotation of fractionated signals within specific windows of interest.This supported identification of a practical critical isthmus in 20 out of 27 completed atrial and ventricular tachycardia activation maps.Conclusions: Our findings suggest that HDM in conjunction with novel automated annotation algorithms provides detailed insights into arrhythmia mechanisms and might facilitate tailored catheter ablation in patients with moderate to great CHD complexity.
Introduction: Tailored catheter ablation of atrial tachycardias (ATs) is increasingly recommended as a potentially easy treatment strategy in the era of high-density mapping (HDM). As follow-up data are sparse, we here report outcomes after HDMguided ablation of ATs in patients with prior catheter ablation or cardiac surgery. Methods and Results: In 250 consecutive patients (age 66.5 ± 0.7 years, 58% male) with ATs (98% prior catheter ablation, 13% prior cardiac surgery) an HDM-guided catheter ablation was performed with the support of a 64-electrode mini-basket catheter. A total of 354 ATs (1.4 ± 0.1 ATs per patient; mean cycle length 304 ± 4.3 ms; 64% macroreentry, 27% localized reentry, and 9% focal) with acute termination of 95% were targeted in the index procedure. A similar AT as in the index procedure recurred in five patients (2%) after a median follow-up time of 535 days (interquartile range (IQR) 25th-75th percentile: 217-841). Tailored ablation of reentry ATs with freedom from any arrhythmia was obtained in 53% after a single procedure and in 73% after 1.4 ± 0.4 ablation procedures (range: 1-4). A total of 228 patients (91%) were free from any arrhythmia recurrence after 210 days (IQR: 152-494) when including optimal usual care. Conclusions: Tailored catheter ablation of ATs guided by HDM has a high acute success rate. The recurrence rate of the index AT is low. In patients with extensive atrial scaring further ablation procedures need to be considered to achieve freedom from any arrhythmia.
Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): DZHK (German Center for Cardiovascular Research) Introduction Cardiac arrhythmia originating from the papillary muscle can trigger ventricular fibrillation and cause sudden cardiac death even in the absence of structural heart disease. Yet, no clinical parameters are known to reflect the propensity of arrhythmia to degenerate into ventricular fibrillation. Purpose We aimed at identification of parameters associated with degeneration of ventricular arrhythmia into ventricular fibrillation. Methods Ventricular arrhythmia was induced by aconitine injection into the papillary muscle of healthy sheep (n = 12) in an open-chest model. Endocardial high-density-mapping and epicardial mapping were performed. We determined repolarization time and activation-recovery-interval according to the Wyatt method. Results During focal arrhythmia faster conduction occurred in longitudinal and basal direction than transversal and apical direction. The electrical restitution curve, modelling relation of diastolic interval and activation-recovery-interval, is steeper in aconitine-induced ventricular arrhythmia than in ventricular pacing or sinus rhythm. Steeper restitution curves reflect electrical instability and propensity to degenerate into ventricular fibrillation. The repolarization-related parameters activation-recovery interval and repolarization time exhibit higher heterogeneity per beat in ventricular arrhythmia preceding degeneration into ventricular fibrillation. Repolarization time in relation to cycle length (RT/CL), which can easily be measured during electrophysiological procedures, differentiates self-limiting from degenerating arrhythmia with high specificity and sensitivity. Conclusion In structurally normal ovine hearts, the ratio of repolarization and cycle length (RT/CL) in ventricular arrhythmia and greater dispersion of repolarization are indicators of subsequent degeneration into ventricular fibrillation. While dispersion of repolarization is not easily acquired in clinical routine, a simple index (RT/CL) may be sufficient to differentiate between self-limiting and electrically instable arrhythmia with propensity to degenerate to ventricular fibrillation. Abstract Figure. Repolarization in VA model
1.1. PurposeHybrid activation mapping is a novel tool to correct for spatial displacement of the mapping catheter due to asymmetrical contraction of myocardium during premature ventricular contractions (PVC). The aim of this study is to describe the extent and cause of spatial displacement during PVC mapping and options for correction using hybrid activation mapping. 1.2. Methods and ResultsWe analyzed 5798 hybrid mapping points in 40 acquired hybrid maps of 22 consecutive patients (age 63±16 years, 45% female) treated for premature ventricular contractions (PVCs). Median PVC-coupling interval was 552 ms (IQR 83 ms). Spatial displacement was determined by measuring the dislocation of the catheter tip during PVC compared to the preceding sinus beat. Mean spatial displacement was 3.8±1.5 mm for all maps. The displacement was 1.3±0.4 mm larger for PVCs with non-outflow-tract origin compared to PVCs originating from the ventricular outflow tracts (RVOT/LVOT; p=0.028). Demographic parameters, PVC-coupling-interval and chamber of origin had no significant influence on the extent of spatial displacement. 1.3. ConclusionEctopic activation of the ventricular myocardium during PVCs results in spatial displacement of mapping points that is significantly larger for PVCs with non-outflow-tract origin. The correction for spatial displacement may improve accuracy of radiofrequency current (RFC)-application in catheter ablation of PVCs.
Background High-density mapping (HDM) has been found to precisely identify the practical isthmus of scar-related atrial tachycardia (AT) circuits. Since practical isthmuses have been found to be shorter than the usual anatomical isthmuses targeted ablation has been proposed. However, outcome data are sparse. Here we describe HDM-guided catheter ablation by targeting the practical isthmus in patients with scar-related ATs. Methods and results In 250 consecutive patients with scar-related ATs HDM-guided catheter ablation with the support of a 64-electrode mini-basket catheter has been performed. Most patients underwent a prior catheter ablation (98%) while 13% had a prior cardiac valve surgery and 6% an underlying congenital heart disease. A total of 355 ATs occurred in the index procedure, of which 64% had a macro-, 26% a micro-reentry and 10% a focal mechanism. The ATs had a mean cycle length of 304±4.3 ms and in 237 patients (95%) an acute termination into sinus rhythm was achieved. They were mainly located in the left atrium (72%) but also in the right atrium (25%), bi-atrially (5%) or in the CS (3%) (see figure). Targeting the practical isthmus revealed arrhythmia freedom in 53% of patients after a single procedure during a mid-term follow-up (median 489 days, range 95–1407 days). Freedom from any arrhythmia could be achieved in 74% of patients after multiple procedures and in 93% of patients after multiple procedures and optimal clinical therapy, including pharmaceutical or electrical cardioversion. Conclusions HDM-guided catheter ablation of the practical isthmus in patients with scar-related ATs leads to a high acute success rate. Nevertheless, multiple procedures are necessary in a relevant number of patients resulting in a low recurrence rate. Funding Acknowledgement Type of funding source: None
Background Cryoballoon (CB)-based pulmonary vein isolation (PVI) currently requires to verify occlusion of each pulmonary vein (PV) using fluoroscopy and dye injection. Objective The current study evaluated whether the novel CB-occlusion tool integrated into the wide-band dielectric imaging system KODEX-EPD reliably verifies occlusion of PV according to a novel dye-injection based algorithm. Methods Consecutive patients suffering from symptomatic atrial fibrillation (AF) underwent CB-based PVI using the KODEX-EPD and the novel occlusion-tool (group I). To confirm accurate display of the PVs, selective PV-angiography was performed in the first half of the patients of group I (group Ia) in addition to a three-dimensional left atrial (LA) map using a spiral mapping catheter (Achieve, SMC1, Medtronic, MN, USA). PV-angiographies were waived for the following patients (group Ib). Procedural duration and radiation exposure were compared to a control group of patients undergoing conventional CB-based PVI. Results CB-based PVI was successful in 50/50 patients of group I (mean age 63±11 years, 18 paroxysmal (36%)) and 25/25 patients of group II (66±10 years, 9 paroxysmal (60%)). Concordance of PV-occlusion as assessed by either PV-occlusion-angiography or KODEX-EPD, was documented in 237/272 (87%) occlusion-analyses among 198 PVs (95% for left superior PV, 93% for left inferior PV, 86% for right inferior PV and 77% for right superior PV). In the final evaluation phase (group Ib) LA fluoroscopy times and dose area products were comparable to the conventional CB-ablation group (10.5±5 vs 8.8±4 minutes (p=0.23) and 403±425 vs 321±202 cGycm2 (p=0.44), whereas the amount of dye could be significantly reduced (group Ib: 31±10 ml vs group II: 70±20 ml, p<0.0001). Conclusion The novel KODEX-EPD PV-occlusion tool allows for accurate PV-occlusion assessment in the majority of PVs and a high acute success rate. The system has the potential to reduce dye and radiation exposure. This should be evaluated in controlled clinical trials. FUNDunding Acknowledgement Type of funding sources: None.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.