Aims: Catheter contact and local tissue characteristics are relevant information for successful radiofrequency current (RFC)-ablation. Local impedance (LI) has been shown to reflect tissue characteristics and lesion formation during RFC-ablation.Using a novel ablation catheter incorporating three mini-electrodes, we investigated LI in relation to generator impedance (GI) in patients with ventricular tachycardia (VT) and its applicability as an indicator of effective RFC-ablation. Methods and Results: Baseline impedance, Δimpedance during ablation and drop rate (Δimpedance/time) were analyzed for 625 RFC-applications in 28 patients with recurrent VT undergoing RFC-ablation. LI was lower in scarred (87.0 Ω [79.0-95.0]) compared to healthy myocardium (97.5 Ω ([82.75-111.50]; P = .03) while GI did not differ between scarred and healthy myocardium. ΔLI was higher (18 Ω [9.4-26.0]) for VT-terminating as compared to non-terminating RFC-ablation (ΔLI 13 Ω [8.85-18.0]; P = .03), but did not differ for ΔGI between terminating vs nonterminating RFCablation. Correspondingly, LI drop rate was higher for RFC-ablation terminating the VT compared with RFC-ablation not terminating the VT (0.63 Ω/s [0.52-0.76] vs 0.32 Ω [0.20-0.58]; P = .008) while there was no difference for GI drop rate. ΔLI was higher in patients with nonischemic cardiomyopathy vs patients with ischemic cardiomyopathy (16 Ω [11.0-20.0] vs 11.0 Ω [7.85-17.00]; P = .003).Conclusion: Our findings suggest that LI is a sensitive parameter to guide RFCablation in patients with VT. LI indicates differences in tissue characteristics and generally is higher in patients with nonischemic cardiomyopathy. Hence, the etiology of the underlying cardiomyopathy needs to be considered when adopting LI for monitoring catheter ablation of VT. K E Y W O R D Scatheter ablation, electrical impedance, high-density mapping, radiofrequency, ventricular tachycardia ---
Background: Ultra-high density mapping (HDM) is a promising tool in the treatment of patients with complex arrhythmias. In adults with congenital heart disease (CHD), rhythm disorders are among the most common complications but catheter ablation can be challenging due to heterogenous anatomy and complex arrhythmogenic substrates. Here, we describe our initial experience using HDM in conjunction with novel automated annotation algorithms in patients with moderate to great CHD complexity.Methods: We studied a series of consecutive adult patients with moderate to great CHD complexity and an indication for catheter ablation due to symptomatic arrhythmia. HDM was conducted using the Rhythmia™ mapping system and a 64-electrode mini-basket catheter for identification of anatomy, voltage, activation pattern and critical areas of arrhythmia for ablation guidance. To investigate novel advanced mapping strategies, postprocedural signal processing using the Lumipoint™ software was applied.Results: In 19 patients (53±3 years; 53% male), 21 consecutive ablation procedures were conducted.Procedures included ablation of atrial fibrillation (n=7; 33%), atrial tachycardia (n=11; 52%), atrioventricular accessory pathway (n=1; 5%), the atrioventricular node (n=1; 5%) and ventricular arrhythmias (n=4; 19%). A total of 23 supraventricular and 8 ventricular arrhythmias were studied with the generation of 56 complete high density maps (atrial n=43; ventricular n=11, coronary sinus n=2) and an average of 12,043±1,679 mapping points. Multiple arrhythmias were observed in n=7 procedures (33% of procedures; range of arrhythmias detected 2-4). A total range of 1-4 critical areas were defined per procedure and treated within a radiofrequency application time of 16 (interquartile range 12-45) minutes. Postprocedural signal processing using Lumipoint™ allowed rapid annotation of fractionated signals within specific windows of interest.This supported identification of a practical critical isthmus in 20 out of 27 completed atrial and ventricular tachycardia activation maps.Conclusions: Our findings suggest that HDM in conjunction with novel automated annotation algorithms provides detailed insights into arrhythmia mechanisms and might facilitate tailored catheter ablation in patients with moderate to great CHD complexity.
Introduction: Tailored catheter ablation of atrial tachycardias (ATs) is increasingly recommended as a potentially easy treatment strategy in the era of high-density mapping (HDM). As follow-up data are sparse, we here report outcomes after HDMguided ablation of ATs in patients with prior catheter ablation or cardiac surgery. Methods and Results: In 250 consecutive patients (age 66.5 ± 0.7 years, 58% male) with ATs (98% prior catheter ablation, 13% prior cardiac surgery) an HDM-guided catheter ablation was performed with the support of a 64-electrode mini-basket catheter. A total of 354 ATs (1.4 ± 0.1 ATs per patient; mean cycle length 304 ± 4.3 ms; 64% macroreentry, 27% localized reentry, and 9% focal) with acute termination of 95% were targeted in the index procedure. A similar AT as in the index procedure recurred in five patients (2%) after a median follow-up time of 535 days (interquartile range (IQR) 25th-75th percentile: 217-841). Tailored ablation of reentry ATs with freedom from any arrhythmia was obtained in 53% after a single procedure and in 73% after 1.4 ± 0.4 ablation procedures (range: 1-4). A total of 228 patients (91%) were free from any arrhythmia recurrence after 210 days (IQR: 152-494) when including optimal usual care. Conclusions: Tailored catheter ablation of ATs guided by HDM has a high acute success rate. The recurrence rate of the index AT is low. In patients with extensive atrial scaring further ablation procedures need to be considered to achieve freedom from any arrhythmia.
Worldwide, ∼4 million people die from sudden cardiac death every year caused in more than half of the cases by ischaemic cardiomyopathy (ICM). Prevention of sudden cardiac death after myocardial infarction by implantation of a cardioverter-defibrillator (ICD) is the most common, even though not curative, therapy to date. Optimized ICD programming should be strived for in order to decrease the incidence of ICD interventions. Catheter ablation reduces the recurrence of ventricular tachycardias (VTs) and is an important adjunct to sole ICD-based treatment or pharmacological antiarrhythmic therapy in patients with ICM, as conclusively demonstrated by seven randomized controlled trials (RCTs) in the last two decades. However, none of the conducted trials was powered to reveal a survival benefit for ablated patients as compared to controls. Whereas thorough consideration of an early approach is necessary following two recent RCTs (PAUSE-SCD, BERLIN VT), catheter ablation is particularly recommended in patients with recurrent VT after ICD therapy. In this context, novel, pathophysiologically driven ablation strategies referring to deep morphological and functional substrate phenotyping based on high-resolution mapping and three-dimensional visualization of scars appear promising. Emerging concepts like sympathetic cardiac denervation as well as radioablation might expand the therapeutical armamentarium especially in patients with therapy-refractory VT. Randomized controlled trials are warranted and on the way to investigate how these translate into improved patient outcome. This review summarizes therapeutic strategies currently available for the prevention of VT recurrences, the optimal timing of applicability, and highlights future perspectives after a PAUSE in BERLIN.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.