Articulated Arm Coordinate Measuring Machines (AACMMs) have gradually evolved and are increasingly used in mechanical industry. At present, measurement uncertainties relating to the use of these devices are not yet well quantified. The work carried out consists of determining the measurement uncertainties of a mechanical part by an AACMM. The studies aiming to develop a model of measurement uncertainty are based on the Monte Carlo method developed in Supplement 1 of the Guide to Expression of Uncertainty in Measurement [] but also identifying and characterizing the main sources of uncertainty. A multi-level Monte Carlo approach principle has been developed which allows for characterizing the possible evolution of the AACMM during the measurement and quantifying in a second level the uncertainty on the considered measurand. The first Monte Carlo level is the most complex and is thus divided into three sub-levels, namely characterization on the positioning error of a point, estimation of calibration errors and evaluation of fluctuations of the ‘localization point’. The global method is thus presented and results of the first sub-level are particularly developed. The main sources of uncertainty, including AACMM deformations, are exposed.
Predicting aortic aneurysm ruptures is a complex problem that has been investigated by many research teams over several decades. Work on this issue is notably complex and involves both the mechanical behavior of the artery and the blood flow. Magnetic resonance imaging (MRI) can provide measurements concerning the shape of an organ and the blood that flows through it. Measuring local distortion of the artery wall is the first essential factor to evaluate in a ruptured artery. This paper aims to demonstrate the feasibility of this measure using MRI on a phantom of an abdominal aortic aneurysm (AAA) with realistic shape. The aortic geometry is obtained from a series of cine-MR images and reconstructed using Mimics software. From 4D flow and MRI measurements, the field of velocity is determined and introduced into a computational fluid dynamic (CFD) model to determine the mechanical boundaries applied on the wall artery (pressure and ultimately wall shear stress (WSS)). These factors are then converted into a solid model that enables wall deformations to be calculated. This approach was applied to a silicone phantom model of an AAA reconstructed from a patient's computed tomography-scan examination. The calculated deformations were then compared to those obtained in identical conditions by stereovision. The results of both methods were found to be close. Deformations of the studied AAA phantom with complex shape were obtained within a gap of 12% by modeling from MR data.
Résumé. Les bras polyarticulés portables ont progressivement évolué et sont de plus en plus utilisés dans l'industrie. Cependant, à l'heure actuelle, la traçabilité de ces dispositifs est difficile à effectuer et les incertitudes de mesures relatives à l'utilisation de ces appareils ne sont pas quantifiées. Le travail mené consiste à déterminer les incertitudes de mesures associées à la quantification, par un bras polyarticulé portable, des caractéristiques géométriques et dimensionnelles d'une pièce mécanique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.