A simple, Accurate, precise method was developed for the simultaneous estimation of the Sofosbuvir and Ledipasvir in Tablet dosage form. Chromatogram was run through Std Discovery C8 150 x 4.6 mm, 5m. Mobile phase containing Buffer 0.1% OPA: Acetonitrile taken in the ratio 60:40 was pumped through column at a flow rate of 1 ml/min. Buffer used in this method was 0.1% OPA buffer. Temperature was maintained at 30°C. Optimized wavelength selected was 260 nm. Retention time of Sofosbuvir and Ledipasvir were found to be 2.367 min and 3.436 min. %RSD of the Sofosbuvir and Ledipasvir were and found to be 0.6 and 0.5 respectively. %Recovery was obtained as 99.61% and 99.80% for Sofosbuvir and Ledipasvir respectively. LOD, LOQ values obtained from regression equations of Sofosbuvir and Ledipasvir were 0.67, 2.02 and 0.70, 2.12 respectively. Regression equation of Sofosbuvir is y = 4266.x + 7700, and y = 4861.x + 2656.of Ledipasvir. Retention times were decreased and run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.
A simple, rapid, precise, sensitive and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for the quantitative analysis of Pitolisant in pharmaceutical dosage form. Chromatographic separation of Pitolisant was achieved on Waters Alliance-e2695, by using Waters X-Bridge Phenyl, 150mm x 4.6mm, 3.5µm, column and the mobile phase containing 0.1% OPA& ACNin the ratio of 30:70% v/v. The flow rate was 1.0 ml/min; detection was carried out by absorption at 210nm using a photodiode array detector at ambient temperature. The number of theoretical plates and tailing factor for Pitolisant was NLT 2000 and should not more than 2respectively. %Relative standard deviation of peak area of all measurements always less than 2.0. The proposed method was validated according to ICH guidelines. The method was found to be simple, economical, suitable, precise, accurate & robust method for quantitative analysis of Pitolisant and study of its stability.
A simple, rapid, precise, sensitive and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for the quantitative analysis of Dolutegravir and Rilpivirine in pharmaceutical dosage form. Chromatographic separation of Dolutegravir and Rilpivirine was achieved on Waters Alliance -2695, by using Luna C18 (250mm x 4.6mm, 5µm) column and the mobile phase containing 0.1% OPA & ACN in the ratio of 50:50 v/v. The flow rate was 1.0 ml/min, detection was carried out by absorption at 245 nm using a photodiode array detector at ambient temperature. The number of theoretical plates and tailing factor for Dolutegravir and Rilpivirine were NLT 2000 and should not more than 2 respectively. The linearity of the method was excellent over the concentration range 10-150 µg/ml and 5-75 µg/ml for Dolutegravir and Rilpivirine respectively. The correlation coefficient was 0.999. % Relative standard deviation of peak areas of all measurements always less than 2.0. The proposed method was validated according to ICH guidelines. The method was found to be simple, economical, suitable, precise, accurate & robust method for quantitative analysis of Dolutegravir and Rilpivirine study of its stability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.