In 18 F-FDG PET, tumors are often characterized by their metabolically active volume and standardized uptake value (SUV). However, many approaches have been proposed to estimate tumor volume and SUV from 18 F-FDG PET images, none of them being widely agreed upon. We assessed the accuracy and robustness of 5 methods for tumor volume estimates and of 10 methods for SUV estimates in a large variety of configurations. Methods: PET acquisitions of an anthropomorphic phantom containing 17 spheres (volumes between 0.43 and 97 mL, sphere-to-surrounding-activity concentration ratios between 2 and 68) were used. Forty-one nonspheric tumors (volumes between 0.6 and 92 mL, SUV of 2, 4, and 8) were also simulated and inserted in a real patient 18 F-FDG PET scan. Four threshold-based methods (including one, T bgd , accounting for background activity) and a model-based method (Fit) described in the literature were used for tumor volume measurements. The mean SUV in the resulting volumes were calculated, without and with partial-volume effect (PVE) correction, as well as the maximum SUV (SUV max ). The parameters involved in the tumor segmentation and SUV estimation methods were optimized using 3 approaches, corresponding to getting the best of each method or testing each method in more realistic situations in which the parameters cannot be perfectly optimized. Results: In the phantom and simulated data, the T bgd and Fit methods yielded the most accurate volume estimates, with mean errors of 2% 6 11% and 28% 6 21% in the most realistic situations. Considering the simulated data, all SUV not corrected for PVE had a mean bias between 231% and 246%, much larger than the bias observed with SUV max (211% 6 23%) or with the PVE-corrected SUV based on T bgd and Fit (22% 6 10% and 3% 6 24%). Conclusion: The method used to estimate tumor volume and SUV greatly affects the reliability of the estimates. The T bgd and Fit methods yielded low errors in volume estimates in a broad range of situations. The PVE-corrected SUV based on T bgd and Fit were more accurate and reproducible than SUV max .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.