The galactose elimination capacity, a measure of the functional liver cell mass, and liver volume were measured in 50 normal subjects of five different age groups (less than 50, 51 to 60, 61 to 70, 71 to 80 and greater than 81 years). The volume of the liver was evaluated by ultrasonography. All subjects had normal routine liver function tests and no history of liver disease. Galactose elimination progressively decreased from 3.05 +/- 0.58 (S.D.) mmoles per min in younger subjects to 1.83 +/- 0.24 mmoles per min in subjects over 81 (p less than 0.00003), without any change in the apparent volume of distribution of the sugar. Similarly, the estimated volume of the liver decreased from 110 +/- 14 units to 75 +/- 13 units with increasing age (p less than 0.0002). Both galactose elimination capacity and the estimated liver volume inversely correlated with age (r = -0.728 and r = -0.579, respectively) whereas a positive correlation was observed between galactose elimination and the estimated liver volume (r = 0.520). Part correlation analysis confirmed that age, when entered in a multiple regression already containing body weight and estimated liver volume as independent variables, had a significant effect on liver function, whereas no significant independent effect of liver volume was present. Both age and body weight had a significant independent effect on the estimated liver volume. The maximum functional capacity of the liver, measured by galactose elimination, is reduced in the elderly. Although several factors may play a role, our data suggest that aging is associated with a slight decline in the intrinsic metabolic activity of the hepatic parenchyma.
Blood flow in the splanchnic veins was studied in cirrhotics and matched controls by means of a system that combines a mechanical sector scanner with a pulsed Doppler. The measurements were validated in an in vitro model. Echo-doppler studies could be carried out reproducibly in only approximately two-thirds of cases because of poor echo transmission or incomplete cooperation. Portal blood velocity was significantly reduced in cirrhotics (10.5 +/- 0.6 cm/s versus 16.0 +/- 0.5 in controls; p less than 0.001), but portal blood flow was normal because of enlarged portal caliber. A complete hemodynamic evaluation of the splenic and superior mesenteric veins was possible in only a few subjects. In selected patients the technique may prove relevant in the study of hemodynamic effects of drugs and surgery on portal blood flow.
A method is described to calculate liver volume at US using real‐time equipment. The method is based on the measurement of the 3 maximum diameters of the liver. Equations were derived by correlation vs CT volume measurement using the 3 diameters (multiple regression) or their product (simple regression) as independent variables in 20 subjects with and without liver disease. It is suggested that liver volume may be estimated as: where y is the volume (in ml), and C – C, A – P, and L – L are the 3 diameters (in cm). The two equations were validated in a second set of 22 subjects. US volume estimated according to Eq. 2 explained approximately 82% of the variance of the actual liver volume. The method is reproducible (interobserver variations <8%), rapid and easy‐to‐repeat. These features make it potentially useful in prospective longitudinal studies.
Zygomatic implant rehabilitation is a challenging procedure that requires an accurate prosthetic and implant plan. The aim of this study was to evaluate the malar bone available for three-dimensional zygomatic implant placement on the possible trajectories exhibiting optimal occlusal emergence. After a preliminary analysis on 30 computed tomography (CT) scans of dentate patients to identify the ideal implant emergencies, we used 80 CT scans of edentulous patients to create two sagittal planes representing the possible trajectories of the anterior and posterior zygomatic implants. These planes were rotated clockwise on the ideal emergence points and three different hypothetical implant trajectories per zygoma were drawn for each slice. Then, the engageable malar bone and intra- and extra-sinus paths were measured. It was possible to identify the ideal implant emergences via anatomical landmarks with a high predictability. Significant differences were evident between males and females, between implants featuring anterior and those featuring posterior emergences, and between the different trajectories. The use of internal trajectories provided better bone engagement but required a higher intra-sinus path. A significant association was found between higher intra-sinus paths and lower crestal bone heights.
Treatment of both Hodgkin's disease (HD) and high-grade non-Hodgkin's lymphoma (HG-NHL) with bulky presentation at diagnosis frequently results in residual masses detected radiologically. Conventional diagnostic radiology and computed tomography (CT) are generally unable to detect the differences between tumor tissue and fibrosis. Gallium-67-citrate (67Ga) SPECT and magnetic resonance imaging (MRI) can potentially differentiate residual active tumor tissue and fibrosis. Thirty-three patients with HD or HG-NHL presenting with bulky mediastinal disease were studied with CT, 67Ga SPECT, and MRI (only for 16 patients) at diagnosis, after two-thirds of their chemotherapy, at the end of chemotherapy, and after radiotherapy in order to evaluate the mediastinal region on the basis of persistence of residual masses and activity of pathological tissue. After treatment, all patients with 67Ga-negative (30/33) disease are still in continuous complete response. Among the three 67Ga-positive patients, 2 relapsed within one year and another one is still alive without evidence of disease. Regarding MRI, two patients were found to be positive, one of them concomitant with 67Ga-positivity; both patients survive in complete response. In lymphoma patients with bulky mediastinal presentation, the 67Ga SPECT remains the preferable imaging technique for monitoring and differentiating the eventual active residual tumor. In combination, CT and 67Ga SPECT represent a suitable complete imaging approach to the radiological diagnosis which may be useful in these particular patients. MRI could probably be considered as a second-line method and from our data would be used only in selected cases because of the high cost, accessibility, and lower specificity as opposed to 67Ga SPECT in evaluating potentially active residual disease.
False aneurysm occurring after replacement of ascending aorta by a vascular prosthesis is a rare, but life-threatening complication. In spite of advances in endovascular techniques, surgery remains the treatment of choice in the majority of cases. We report the case of a huge pseudoaneurysm caused by late dehiscence of the right coronary ostium-aortic tubular graft anastomosis, occurred 30 years after replacement of aortic valve and ascending aorta by classical Bentall operation. A fistula originating from the aneurysmal sac extended across the sternum into the thoracic subcutaneous soft tissues and gave rise to a pulsatile mass well appreciable on the anterior chest wall. The surgical treatment, consisting of partial resection of the aortic tubular graft and sternal reconstruction was effective and uneventful.
Aim of the study: to evaluate root filling remnants after secondary root canal treatments (SRCTs) of oval-shaped canals with X-rays and cone beam computed tomography (CBCT). The SRCTs were performed using reciprocating NiTi instruments. Methods: Single-rooted teeth (N = 64) were randomly treated with Reciproc Blue (RB) and filled with AH Plus/single cone (SC group) or AH Plus/Guttafusion (GF group). After seven days of storage in HBSS (Hanks balanced salt solution), Gates Glidden burs #2/3 and RB #25 and #40 were used for the SRCTs. The time to complete the procedure was measured. X-rays and CBCT were used to calculate, respectively, the area and the volume occupied by the remnants in the coronal, middle, and apical thirds of each canal. Environmental scanning electron microscopy (ESEM) and energy dispersive X-ray spectroscopy (EDX) were used for qualitative evaluation and morphology composition of the remnants in sectioned roots. A statistical analysis was performed using Sigma Plot (version 13, IBM, Armonk, NY, USA). The study was designed according to PRILE guidelines. Results: After the SRCTs, the middle thirds of the root canals showed the presence of remnants in both groups, as demonstrated by X-rays and CBCT. The GF group showed a statistically significant higher volume of remnants than the SC Group only in the middle third. The ESEM supported by the EDX revealed the remnant composition by the detection of trace elements of sealer and gutta-percha in all root canals. Conclusion: The study demonstrated that the middle third of root canals is a critical region where remnants were packed and spread in the buccal-lingual sides of canals. ESEM-EDX detected a fine layer of filling remnants in all root thirds, suggesting a larger canal contamination than the X-rays and CBCT examinations revealed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.