A validated, highly sensitive, and selective HPLC method with MS-MS detection has been developed for quantitative determination of azithromycin (AZI) in human Na2EDTA plasma. Roxithromycin (ROX) was used as internal standard. Human plasma containing AZI and internal standard was ultrafiltered through Centrifree Micropartition devices and the concentration of AZI was determined by isocratic HPLC-MS-MS. Multiple reaction monitoring mode (MRM) was used for MS-MS detection. The calibration plot was linear in the concentration range 2.55-551.43 ng mL(-1). Inter-day and Intra-day precision and accuracy of the proposed method were characterized by R.S.D and percentage deviation, respectively; both were less than 8%. Limit of quantification was 2.55 ng mL(-1). The proposed method was used to determine the pharmacokinetic profile of AZI (250-mg tablets).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.