The temperature dependencies of magnetoimpedance (MI) and stress impedance (SI) were analyzed both in the as-quenched soft magnetic Co68.5Fe4Si15B12.5 ribbons and after their heat treatment at 425 K for 8 h. It was found that MI shows weak changes under the influence of mechanical stresses in the temperature range of 295–325 K and SI does not exceed 10%. At higher temperatures, the MI changes significantly under the influence of mechanical stresses, and SI variations reach 30%. Changes in the magnetoelastic properties for the different temperatures were taken into consideration for the discussion of the observed MI and SI responses. The solutions for the problem of thermal stability of the magnetic sensors working on the principles of MI or SI were discussed taking into account the joint contributions of the temperature and the applied mechanical stresses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.