Single-shot spiral IDEAL imaging of gas, PT and RBC compartments and gas exchange is feasible in rat lung using Hp (129) Xe. Magn Reson Med 76:566-576, 2016. © 2015 Wiley Periodicals, Inc.
Purpose To derive lobar ventilation in patients with chronic obstructive pulmonary disease (COPD) using a rapid time-series hyperpolarized xenon-129 (HPX) magnetic resonance imaging (MRI) technique and compare this to ventilation/perfusion single-photon emission computed tomography (V/Q-SPECT), correlating the results with high-resolution computed tomography (CT) and pulmonary function tests (PFTs). Materials and methods Twelve COPD subjects (GOLD stages I–IV) participated in this study and underwent HPX-MRI, V/Q-SPECT/CT, high-resolution CT, and PFTs. HPX-MRI was performed using a novel time-series spiral k-space sampling approach. Relative percentage ventilations were calculated for individual lobe for comparison to the relative SPECT lobar ventilation and perfusion. The absolute HPX-MRI percentage ventilation in each lobe was compared to the absolute CT percentage emphysema score calculated using a signal threshold method. Pearson’s correlation and linear regression tests were performed to compare each imaging modality. Results Strong correlations were found between the relative lobar percentage ventilation with HPX-MRI and percentage ventilation SPECT ( r = 0.644; p < 0.001) and percentage perfusion SPECT ( r = 0.767; p < 0.001). The absolute CT percentage emphysema and HPX percentage ventilation correlation was also statistically significant ( r = 0.695, p < 0.001). The whole lung HPX percentage ventilation correlated with the PFT measurements (FEV 1 with r = − 0.886, p < 0.001*, and FEV 1 /FVC with r = − 0.861, p < 0.001*) better than the whole lung CT percentage emphysema score (FEV 1 with r = − 0.635, p = 0.027; and FEV 1 /FVC with r = − 0.652, p = 0.021). Conclusion Lobar ventilation with HPX-MRI showed a strong correlation with lobar ventilation and perfusion measurements derived from SPECT/CT, and is better than the emphysema score obtained with high-resolution CT. Key Points • The ventilation hyperpolarized xenon-129 MRI correlates well with ventilation and perfusion with SPECT/CT with the advantage of higher temporal and spatial resolution. • The hyperpolarized xenon-129 MRI correlates with the PFT measurements better than the high-resolution CT with the advantage of avoiding the use of ionizing radiation. Electronic supplementary material The online version of this article (10.1007/s00330-018-5888-y) contains supplementary material,...
Regional RILI can be detected two weeks post-irradiation using HP (129)Xe MRI and analysis of gas exchange curves. This approach correlates well with histology and can potentially be used clinically to assess radiation pneumonitis associated with early RILI to improve radiation therapy outcomes.
PurposeTo develop and optimize a rapid dynamic hyperpolarized 129Xe ventilation (DXeV) MRI protocol and investigate the feasibility of capturing pulmonary signal‐time curves in human lungs.Theory and MethodsSpiral k‐space trajectories were designed with the number of interleaves N int = 1, 2, 4, and 8 corresponding to voxel sizes of 8 mm, 5 mm, 4 mm, and 2.5 mm, respectively, for field of view = 15 cm. DXeV images were acquired from a gas‐flow phantom to investigate the ability of N int = 1, 2, 4, and 8 to capture signal‐time curves. A finite element model was constructed to investigate gas‐flow dynamics corroborating the experimental signal‐time curves. DXeV images were also carried out in six subjects (three healthy and three chronic obstructive pulmonary disease subjects).ResultsDXeV images and numerical modelling of signal‐time curves permitted the quantification of temporal and spatial resolutions for different numbers of spiral interleaves. The two‐interleaved spiral (N int = 2) was found to be the most time‐efficient to obtain DXeV images and signal‐time curves of whole lungs with a temporal resolution of 624 ms for 13 slices. Signal‐time curves were well matched in three healthy volunteers. The Spearman's correlations of chronic obstructive pulmonary disease subjects were statistically different from three healthy subjects (P < 0.05).ConclusionThe N int = 2 spiral demonstrates the successful acquisition of DXeV images and signal‐time curves in healthy subjects and chronic obstructive pulmonary disease patients. Magn Reson Med 79:2597–2606, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Purpose To perform magnetic resonance imaging (MRI), human lung imaging, and quantification of the gas-transfer dynamics of hyperpolarized xenon-129 (HPX) from the alveoli into the blood plasma. Materials and methods HPX MRI with iterative decomposition of water and fat with echo asymmetry and least-square estimation (IDEAL) approach were used with multi-interleaved spiral k-space sampling to obtain HPX gas and dissolved phase images. IDEAL time-series images were then obtained from ten subjects including six normal subjects and four patients with pulmonary emphysema to test the feasibility of the proposed technique for capturing xenon-129 gas-transfer dynamics (XGTD). The dynamics of xenon gas diffusion over the entire lung was also investigated by measuring the signal intensity variations between three regions of interest, including the left and right lungs and the heart using Welch’s t test. Results The technique enabled the acquisition of HPX gas and dissolved phase compartment images in a single breath-hold interval of 8 s. The y -intersect of the XGTD curves were also found to be statistically lower in the patients with lung emphysema than in the healthy group ( p < 0.05). Conclusion This time-series IDEAL technique enables the visualization and quantification of inhaled xenon from the alveoli to the left ventricle with a clinical gradient strength magnet during a single breath-hold, in healthy and diseased lungs. Key Points • The proposed hyperpolarized xenon-129 gas and dissolved magnetic resonance imaging technique can provide regional and temporal measurements of xenon-129 gas-transfer dynamics. • Quantitative measurement of xenon-129 gas-transfer dynamics from the alveolar to the heart was demonstrated in normal subjects and pulmonary emphysema. • Comparison of gas-transfer dynamics in normal subjects and pulmonary emphysema showed that the proposed technique appears sensitive to changes affecting the alveoli, pulmonary interstitium, and capillaries. Electronic supplementary material The online version of this article (10.1007/s00330-018-5853-9) contains supplementary material, which is available to authorized users.
To compare the distribution of pulmonary ventilation assessed by a CT-based full-scale airway network (FAN) flow model with hyperpolarized xenon 129 ( 129 Xe) MRI (hereafter, 129 Xe MRI) and technetium 99m-diethylenetriaminepentaacetic acid aerosol SPECT ventilation imaging (hereafter, V-SPECT) in participants with COPD. Materials and Methods:In this prospective study performed between May and August 2017, pulmonary ventilation in participants with COPD was computed by using the FAN flow model. The modeled pulmonary ventilation was compared with functional imaging data from breath-hold time-series 129 Xe MRI and V-SPECT. FAN-derived ventilation images on the coronal plane and volumes of interest were compared with functional lung images. Percentage lobar ventilation estimated by the FAN model was compared with that measured at 129 Xe MRI and V-SPECT. The statistical significance of ventilation distribution between FAN and functional images was demonstrated with the Spearman correlation coefficient and x 2 distance.Results: For this study, nine participants (seven men [mean age, 65 years 6 5 {standard deviation}] and two women [mean age, 63 years 6 7]) with COPD that was Global Initiative for Chronic Obstructive Lung Disease stage II-IV were enrolled. FAN-modeled ventilation profile showed strong positive correlation with images from 129 Xe MRI (r = 0.67; P , .001) and V-SPECT (r = 0.65; P , .001). The x 2 distances of the ventilation histograms in the volumes of interest between the FAN and 129 Xe MRI and FAN and V-SPECT were 0.16 6 0.08 and 0.28 6 0.14, respectively. The ratios of lobar ventilations in the models were linearly correlated to images from 129 Xe MRI (r = 0.67; P , .001) and V-SPECT (r = 0.59; P , .001). Conclusion:A CT-based full-scale airway network flow model provided regional pulmonary ventilation information for chronic obstructive pulmonary disease and correlates with hyperpolarized xenon 129 MRI and technetium 99m-diethylenetriaminepentaacetic acid aerosol SPECT ventilation imaging.
This paper reports a new effect whereby a physiological-level direct-current electrical field (at 1.4 V/cm) can induce time-varying mechanical strain in various types of biological tissues and gel phantoms. This effect cannot be explained by the piezoelectric effect, tissue contraction, temperature changes, and electrorestriction. The induced strain in tissues was analyzed by processing ultrasound echo signals. The sample expanded perpendicularly to the applied electric field. The expansion rate depended on the history of the applied electric field. The speed of sound changed little compared with the expansion. The new effect might be related to electrokinetic effects.
Objectives To investigate the use of a fast dynamic hyperpolarised 129 Xe ventilation magnetic resonance imaging (DXeV-MRI) method for detecting and quantifying delayed ventilation in patients with chronic obstructive pulmonary disease (COPD). Methods Three male participants (age range 31-43) with healthy lungs and 15 patients (M/F = 12:3, age range = 48-73) with COPD (stages II-IV) underwent spirometry tests, quantitative chest computed tomography (QCT), and DXeV-MRI at 1.5-Tesla. Regional delayed ventilation was captured by measuring the temporal signal change in each lung region of interest (ROI) in comparison to that in the trachea. In addition to its qualitative assessment through visual inspection by a clinical radiologist, delayed ventilation was quantitatively captured by calculating a covariance measurement of the lung ROI and trachea signals, and quantified using both the time delay, and the difference between the integrated areas covered by the signal-time curves of the two signals. Results Regional temporal ventilation, consistent with the expected physiological changes across a free breathing cycle, was demonstrated with DXeV-MRI in all patients. Delayed ventilation was observed in 13 of the 15 COPD patients and involved variable lung ROIs. This was in contrast to the control group, where no delayed ventilation was demonstrated (p = 0.0173). Conclusions DXeV-MRI offers a non-invasive way of detecting and quantifying delayed ventilation in patients with COPD, and provides physiological information on regional pulmonary function during a full breathing cycle. Key Points • Dynamic xenon MRI allows for the non-invasive detection and measurement of delayed ventilation in COPD patients. • Dynamic xenon MRI during a free breathing cycle can provide unique information about pulmonary physiology and pulmonary disease pathophysiology. • With further validation, dynamic xenon MRI could offer a non-invasive way of measuring collateral ventilation which can then be used to guide lung volume reduction therapy (LVRT) for certain COPD patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.