Background: Reliable point-of-care (POC) diagnostics not requiring laboratory infrastructure could be a game changer in the COVID-19 pandemic, particularly in the Global South. We assessed performance, limit of detection (LOD) and ease-of-use of three antigen-detecting, rapid POC diagnostics (Ag-RDT) for SARS-CoV-2. Methods: This prospective, multi-centre diagnostic accuracy study, recruited participants suspected to have SARS-CoV2 in Germany and UK. Paired nasopharyngeal swabs (NP) or NP and/or oropharyngeal swabs (OP) were collected from participants (one for clinical real-time reverse transcription polymerase chain reaction (RT-PCR) and one for Ag-RDT testing). Performance of each of three Ag-RDTs was compared to RT-PCR overall, and according to predefined subcategories e.g. cycle threshold (CT)-value, days from symptom onset, etc. In addition, limited verification of analytical limit-of-detection (LOD) was determined. To understand the usability of each Ag-RDT a System Usability Scale (SUS) questionnaire and ease-of-use assessment were performed. Results: Between April 17th and August 25th, 2020, 2417 participants were enrolled, with 70 (3.0%) testing positive by RT-PCR. The best-performing test (SD Biosensor, Inc. STANDARD Q) was 76.6% [95% Confidence Interval (CI) 62.8-86.4] sensitive and 99.3% [CI 98.6-99.6] specific. A sub-analysis showed all samples with RT-PCR CT-values <25 were detectable by STANDARD Q. The test was considered easy-to-use (SUS 86/100) and suitable for POC. Bioeasy and Coris showed specificity of 93.1% [CI 91.0%-94.8%] and 95.8% [CI 93.4%-97.4%], respectively, not meeting the predefined target of ≥98%. Conclusion: There is large variability in performance of Ag-RDT tests with one test showing promise. Given the usability at POC, these tests are likely to have impact despite imperfect sensitivity; however further research and modelling are needed.
Background: Two antigen-detecting rapid diagnostic tests (Ag-RDTs) are now approved through the WHO Emergency Use Listing procedure and can be performed at the point-of-care. However, both tests use nasopharyngeal (NP) swab samples. NP swab samples must be collected by trained healthcare personnel with protective equipment and are frequently perceived as uncomfortable by patients. Methods: This was a manufacturer-independent, prospective diagnostic accuracy study with comparison of a supervised, self-collected anterior nasal (AN) swab sample with a professional-collected NP swab sample, using a WHO-listed SARS-CoV-2 Ag-RDT, STANDARD Q COVID-19 Ag Test (SD Biosensor), which is also being distributed by Roche. The reference standard was RT-PCR from an oro-/nasopharyngeal swab sample. Percent positive and negative agreement as well as sensitivity and specificity were calculated. Results: Among the 289 participants, 39 (13.5%) tested positive for SARS-CoV-2 by RT-PCR. The positive percent agreement of the two different sampling techniques for the Ag-RDT was 90.6% (CI 75.8-96.8). The negative percent agreement was 99.2% (CI 97.2-99.8). The Ag-RDT with AN sampling showed a sensitivity of 74.4% (29/39 PCR positives detected; CI 58.9-85.4) and specificity of 99.2% (CI 97.1-99.8) compared to RT-PCR. The sensitivity with NP sampling was 79.5% (31/39 PCR positives detected; CI 64.5-89.2) and specificity was 99.6% (CI 97.8-100). In patients with high viral load (>7.0 log10 RNA SARS-CoV2/swab), the sensitivity of the Ag-RDT with AN sampling was 96% and 100% with NP sampling. Conclusion: Supervised self-sampling from the anterior nose is a reliable alternative to professional nasopharyngeal sampling using a WHO-listed SARS-CoV-2 Ag-RDT. Considering the ease-of-use of Ag-RDTs, self-sampling and potentially patient self-testing at home may be a future use case.
In 2020, the World Health Organization (WHO) recommended two SARS-CoV-2 lateral flow antigen-detecting rapid diagnostics tests (Ag-RDTs), both initially with nasopharyngeal (NP) sample collection. Independent head-to-head studies are necessary for SARS-CoV-2 Ag-RDT nasal sampling to demonstrate comparability of performance with nasopharyngeal (NP) sampling. We conducted a head-to-head comparison study of a supervised, self-collected nasal mid-turbinate (NMT) swab and a professional-collected NP swab, using the Panbio™ Ag-RDT (distributed by Abbott). We calculated positive and negative percent agreement between the sampling methods as well as sensitivity and specificity for both sampling techniques compared to the reference standard reverse transcription polymerase chain reaction (RT-PCR). A SARS-CoV-2 infection could be diagnosed by RT-PCR in 45 of 290 participants (15.5%). Comparing the NMT and NP sampling the positive percent agreement of the Ag-RDT was 88.1% (37/42 PCR positives detected; CI 75.0–94.8%). The negative percent agreement was 98.8% (245/248; CI 96.5–99.6%). The overall sensitivity of Panbio with NMT sampling was 84.4% (38/45; CI 71.2–92.3%) and 88.9% (40/45; CI 76.5–95.5%) with NP sampling. Specificity was 99.2% (243/245; CI 97.1–99.8%) for both, NP and NMT sampling. The sensitivity of the Panbio test in participants with high viral load (> 7 log10 SARS-CoV-2 RNA copies/mL) was 96.3% (CI 81.7–99.8%) for both, NMT and NP sampling. For the Panbio supervised NMT self-sampling yields comparable results to NP sampling. This suggests that nasal self-sampling could be used for to enable scaled-up population testing.Clinical Trial DRKS00021220.
Background Considering the possibility of nasal self-sampling and the ease of use in performing SARS-CoV-2 antigen-detecting rapid diagnostic tests (Ag-RDTs), self-testing is a feasible option. Objective The goal of this study was a head-to-head comparison of diagnostic accuracy of patient self-testing with professional testing using a SARS-CoV-2 Ag-RDT. Study design We performed a manufacturer-independent, prospective diagnostic accuracy study of nasal mid-turbinate self-sampling and self-testing with symptomatic adults using a WHO-listed SARS-CoV-2 Ag-RDT. Procedures were observed without intervention. For comparison, Ag-RDTs with nasopharyngeal sampling were professionally performed. Estimates of agreement, sensitivity, and specificity relative to RT-PCR on a combined oro-/nasopharyngeal sample were calculated. Feasibility was evaluated by observer and participant questionnaires. Results Among 146 symptomatic adults, 40 (27.4%) were RT-PCR-positive for SARS-CoV-2. Sensitivity with self-testing was 82.5% (33/40; 95% CI 68.1-91.3), and 85.0% (34/40; 95% CI 70.9-92.9) with professional testing. At high viral load (≥7.0 log 10 SARS-CoV-2 RNA copies/ml), sensitivity was 96.6% (28/29; 95% CI 82.8-99.8) for both self- and professional testing. Deviations in sampling and testing were observed in 25 out of the 40 PCR-positives. Most participants (80.9%) considered the Ag-RDT as easy to perform. Conclusion Laypersons suspected for SARS-CoV-2 infection were able to reliably perform the Ag-RDT and test themselves. Procedural errors might be reduced by refinement of the instructions for use or the product design/procedures. Self-testing allows more wide-spread and frequent testing. Paired with the appropriate information of the public about the benefits and risks, self-testing may have significant impact on the pandemic.
Introduction Most SARS-CoV-2 antigen-detecting rapid diagnostic tests require nasopharyngeal sampling, which is frequently perceived as uncomfortable and requires healthcare professionals, thus limiting scale-up. Nasal sampling could enable self-sampling and increase acceptability. The term nasal sampling is often not used uniformly and sampling protocols differ. Methods This manufacturer-independent, prospective diagnostic accuracy study, compared professional anterior nasal and nasal mid-turbinate sampling for a WHO-listed SARS-CoV-2 antigen-detecting rapid diagnostic test. The second group of participants collected a nasal mid-turbinate sample themselves and underwent a professional nasopharyngeal swab for comparison. The reference standard was real-time polymerase chain reaction (RT-PCR) using combined oro-/nasopharyngeal sampling. Individuals with high suspicion of SARS-CoV-2 infection were tested. Sensitivity, specificity, and percent agreement were calculated. Self-sampling was observed without intervention. Feasibility was evaluated by observer and participant questionnaires. Results Among 132 symptomatic adults, both professional anterior nasal and nasal mid-turbinate sampling yielded a sensitivity of 86.1% (31/36 RT-PCR positives detected; 95%CI: 71.3–93.9) and a specificity of 100.0% (95%CI: 95.7–100). The positive percent agreement was 100% (95%CI: 89.0–100). Among 96 additional adults, self nasal mid-turbinate and professional nasopharyngeal sampling yielded an identical sensitivity of 91.2% (31/34; 95%CI 77.0–97.0). Specificity was 98.4% (95%CI: 91.4–99.9) with nasal mid-turbinate and 100.0% (95%CI: 94.2–100) with nasopharyngeal sampling. The positive percent agreement was 96.8% (95%CI: 83.8–99.8). Most participants (85.3%) considered self-sampling as easy to perform. Conclusion Professional anterior nasal and nasal mid-turbinate sampling are of equivalent accuracy for an antigen-detecting rapid diagnostic test in ambulatory symptomatic adults. Participants were able to reliably perform nasal mid-turbinate sampling themselves, following written and illustrated instructions. Nasal self-sampling will facilitate scaling of SARS-CoV-2 antigen testing.
Objectives Diagnostics are essential for controlling the pandemic. Identifying a reliable and fast diagnostic device is needed for effective testing. We assessed performance and ease-of-use of the Abbott PanBio antigen-detecting rapid diagnostic test (Ag-RDT). Methods This prospective, multi-centre diagnostic accuracy study enrolled at two sites in Germany. Following routine testing with reverse-transcriptase polymerase chain reaction (RT-PCR), a second study-exclusive swab was performed for Ag-RDT testing. Routine swabs were nasopharyngeal (NP) or combined NP/oropharyngeal (OP) whereas the study-exclusive swabs were NP. To evaluate performance, sensitivity and specificity were assessed overall and in predefined sub-analyses accordingly to cycle-threshold values, days after symptom onset, disease severity and study site. Additionally, an ease-of-use assessment (EoU) and System Usability Scale (SUS) were performed. Results 1108 participants were enrolled between Sept 28 and Oct 30, 2020. Of these, 106 (9.6%) were PCR-positive. The Abbott PanBio detected 92/106 PCR-positive participants with a sensitivity of 86.8% (95% CI: 79.0% - 92.0%) and a specificity of 99.9% (95% CI: 99.4%-100%). The sub-analyses indicated that sensitivity was 95.8% in Ct-values <25 and within the first seven days from symptom onset. The test was characterized as easy to use (SUS: 86/100) and considered suitable for point-of-care settings. Conclusion The Abbott PanBio Ag-RDT performs well for SARS-CoV-2 testing in this large manufacturer independent study, confirming its WHO recommendation for Emergency Use in settings with limited resources.
Background Antigen-detecting rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 are important diagnostic tools. We assessed clinical performance and ease-of-use of seven Ag-RDTs in a prospective, manufacturer-independent, multi-centre cross-sectional diagnostic accuracy study to inform global decision makers. Methods Unvaccinated participants suspected of a first SARS-CoV-2 infection were recruited at six sites (Germany, Brazil). Ag-RDTs were evaluated sequentially, with collection of paired swabs for routine reverse transcription polymerase chain reaction (RT-PCR) testing and Ag-RDT testing. Performance was compared to RT-PCR overall and in sub-group analyses (viral load, symptoms, symptoms duration). To understandusability a System Usability Scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. Findings 7471 participants were included in the analysis. Sensitivities across Ag-RDTs ranged from 70·4%-90·1%, specificities were above 97·2% for all Ag-RDTs but one (93·1%).Ag-RDTs, Mologic, Bionote, Standard Q, showed diagnostic accuracy in line with WHO targets (> 80% sensitivity, > 97% specificity). All tests showed high sensitivity in the first three days after symptom onset (≥87·1%) and in individuals with viral loads≥ 6 log 10 SARS-CoV2 RNA copies/mL (≥ 88·7%). Usability varied, with Rapigen, Bionote and Standard Q reaching very good scores; 90, 88 and 84/100, respectively. Interpretation Variability in test performance is partially explained by variable viral loads in population evaluated over the course of the pandemic. All Ag-RDTs reach high sensitivity early in the disease and in individuals with high viral loads, supporting their role in identifying transmission relevant infections. For easy-to-use tests, performance shown will likely be maintained in routine implementation. Funding Ministry of Science, Research and Arts, State of Baden-Wuerttemberg, Germany, internal funds from Heidelberg University Hospital, University Hospital Charité − Universitätsmedizin Berlin, UK Department of International Development, WHO, Unitaid.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.