The radiological assessment of muscle properties—size, mass, density (also termed radiodensity), composition, and adipose tissue infiltration—is fundamental in muscle diseases. More recently, it also became obvious that muscle atrophy, also termed muscle wasting, is caused by or associated with many other diseases or conditions, such as inactivity, malnutrition, chronic obstructive pulmonary disorder, cancer-associated cachexia, diabetes, renal and cardiac failure, and sarcopenia and even potentially with osteoporotic hip fracture. Several techniques have been developed to quantify muscle morphology and function. This review is dedicated to quantitative computed tomography (CT) of skeletal muscle and only includes a brief comparison with magnetic resonance imaging. Strengths and limitations of CT techniques are discussed in detail, including CT scanner calibration, acquisition and reconstruction protocols, and the various quantitative parameters that can be measured with CT, starting from simple volume measures to advanced parameters describing the adipose tissue distribution within muscle. Finally, the use of CT in sarcopenia and cachexia and the relevance of muscle parameters for the assessment of osteoporotic fracture illustrate the application of CT in two emerging areas of medical interest.
We developed a new precise 3D segmentation technique for quantification of bone erosions in HR-pQCT datasets that correlates to the volume, shape and surface area of the erosion. The technique allows fast and effective measurement of the erosion size and could therefore be helpful for rapid and quantitative assessment of erosion size.
BackgroundA change of loading conditions in the knee causes changes in the subchondral bone and may be a cause of osteoarthritis (OA). However, quantification of trabecular architecture in vivo is difficult due to the limiting spatial resolution of the imaging equipment; one approach is the use of texture parameters. In previous studies, we have used digital models to simulate changes of subchondral bone architecture under OA progression. One major result was that, using computed tomography (CT) images, subchondral bone mineral density (BMD) in combination with anisotropy and global homogeneity could characterize this progression.The primary goal of this study was a comparison of BMD, entropy, anisotropy, variogram slope, and local and global inhomogeneity measurements between high-resolution peripheral quantitative CT (HR-pQCT) and CT using human cadaveric knees. The secondary goal was the verification of the spatial resolution dependence of texture parameters observed in the earlier simulations, two important prerequisites for the interpretation of in vivo measurements in OA patients.MethodThe applicability of texture analysis to characterize bone architecture in clinical CT examinations was investigated and compared to results obtained from HR-pQCT. Fifty-seven human knee cadavers (OA status unknown) were examined with both imaging modalities. Three-dimensional (3D) segmentation and registration processes, together with automatic positioning of 3D analysis volumes of interest (VOIs), ensured the measurement of BMD and texture parameters at the same anatomical locations in CT and HR-pQCT datasets.ResultsAccording to the calculation of dice ratios (>0.978), the accuracy of VOI locations between methods was excellent. Entropy, anisotropy, and global inhomogeneity showed significant and high linear correlation between both methods (0.68 < R
2 < 1.00). The resolution dependence of these parameters simulated earlier was confirmed by the in vitro measurements.ConclusionThe high correlation of HR-pQCT- and CT-based measurements of entropy, global inhomogeneity, and anisotropy suggests interchangeability between devices regarding the quantification of texture. The agreement of the experimentally determined resolution dependence of global inhomogeneity and anisotropy with earlier simulations is an important milestone towards their use to quantify subchondral bone structure. However, an in vivo study is still required to establish their clinical relevance.
Longitudinal changes in erosion size and shape and of BMD in the vicinity of an erosion can be measured. BMD changes are associated with progression and regression of erosions. However, the semi-automated and manual approaches did not classify longitudinal changes of erosion volume in the same way. Further research is necessary to define the nature of these differences.
Many studies use threshold-based techniques to assess in vivo the muscle, bone and adipose tissue distribution of the legs using computed tomography (CT) imaging. More advanced techniques divide the legs into subcutaneous adipose tissue (SAT), anatomical muscle (muscle tissue and adipocytes within the muscle border) and intra- and perimuscular adipose tissue. In addition, a so-called muscle density directly derived from the CT-values is often measured. We introduce a new integrated approach to quantify the muscle-lipid system (MLS) using quantitative CT in patients with sarcopenia or osteoporosis. The analysis targets the thigh as many CT studies of the hip do not include entire legs The framework consists of an anatomic coordinate system, allowing delineation of reproducible volumes of interest, a robust semi-automatic 3D segmentation of the fascia and a comprehensive method to quantify of the muscle and lipid distribution within the fascia. CT density-dependent features are calibrated using subject-specific internal CT values of the SAT and external CT values of an in scan calibration phantom. Robustness of the framework with respect to operator interaction, image noise and calibration was evaluated. Specifically, the impact of inter- and intra-operator reanalysis precision and addition of Gaussian noise to simulate lower radiation exposure on muscle and AT volumes, muscle density and 3D texture features quantifying MLS within the fascia, were analyzed. Existing data of 25 subjects (age: 75.6 ± 8.7) with porous and low-contrast muscle structures were included in the analysis. Intra- and inter-operator reanalysis precision errors were below 1% and mostly comparable to 1% of cohort variation of the corresponding features. Doubling the noise changed most 3D texture features by up to 15% of the cohort variation but did not affect density and volume measurements. The application of the novel technique is easy with acceptable processing time. It can thus be employed for a comprehensive quantification of the muscle-lipid system enabling radiomics approaches to musculoskeletal disorders.
BMD was examined exactly at BML locations and surrounding bone using highly accurate segmentation and registration methods. BMD was significantly increased at BML locations (P < 0.05).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.