This paper presents a comparison of triple quadrupole tandem mass spectrometry (MS/MS) and Orbitrap high-resolution mass spectrometry (HRMS) combined to ultrahigh performance liquid chromatography for the determination of glucocorticoids and polyether ionophores in sewage, in order to show the major benefits and drawbacks for each mass spectrometry analyser. Overall, HRMS measurements have enhanced performance in terms of confirmatory capabilities than MS/MS measurements. Moreover, similar limits of quantification, limits of detection, linear range and repeatability for glucocorticoids with both the MS/MS and HRMS methods were compared, but in the case of polyether ionophores, slightly better limits of detection and limits of quantification were obtained with the HRMS method because of the high sensitivity obtained when diagnostic ions are used for quantification instead of selected reaction monitoring transitions for these compounds. The two methods have been applied to the analysis of several influent and effluent sewage samples from sewage treatment plants located in the Tarragona region (Catalonia, Spain), showing an excellent correlation between the two methods.
The results obtained in this study demonstrate the capability of LC-Orbitrap-MS for accurate trace analysis of these very polar contaminants. This method permitted to identify cyclophosphamide and epirubicin in wastewaters and influents of WWTP, but no traces were detected in WWTP effluents. The methodology herein developed is sensitive and robust and applicable for screening of a large number of samples since no preconcentration is needed.
High-resolution tandem mass spectrometry by collision-induced dissociation with a linear ion trap-Orbitrap has been performed on marine dissolved organic matter (DOM). Product ion spectra of selected precursor ions (m/z 359-375) have been acquired to obtain structural information, after method development. To evaluate the performance of the method, the Suwannee River fulvic acid (SRFA) reference standard was also analyzed. By reconstructing the individual product ion spectrum of marine DOM, several fragments were assigned to the different precursor ions indicating the presence of carboxyl, hydroxyl, lactones, quinones, esters, and structures more similar to lignin-degraded molecules. On the basis of these findings, coastal marine DOM molecules, although structurally homogeneous, might be more rich in diversity of functional groups than previously described.
A simultaneous derivatization/extraction method followed by liquid chromatography-electrospray-high resolution mass spectrometry for the determination of volatile thiols in hydroalcoholic matrixes was optimized and used to identify and quantify volatile thiols in wine and beer samples. The method was evaluated in terms of sensitivity, precision, accuracy and selectivity. The experimental LOQs of eleven thiols tested ranged between 0.01 ng/L and 10 ng/L. Intra-day relative standard deviation (RSD) was in general lower than 10% and inter-day RSD ranged between 10% and 30%. Recovery in the model and real matrixes ranged from 45% to 129%. The method was then applied for the analysis of four white wines and six beers. Five out of the eleven reference thiols were identified and quantified in the samples analyzed. The non-target approach, carried out by monitoring the diagnostic ion at m/z 275.9922 [C13H10ONSe](+) in the fragmentation spectrum, allowed detecting, in the same samples, fourteen non-target thiols.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.